Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Solvari Inc: SVR-A10-208 {208V} — CEC Inverter Specifications

Manufacturer: Solvari Inc Registry: CEC Verified Engineering Specification

Solvari Inc: SVR-A10-208 {208V} outputs 303 W AC at 208 V, commercial single-phase (1.5 A continuous, 15 A OCPD), ranking #1,770 of 2,343 CEC inverters at 96.3% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
303 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.3%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solvari Inc: SVR-A10-208 {208V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Solvari Inc: SVR-A10-208 {208V}.

For NEC 705.12 solar interconnection, Solvari Inc: SVR-A10-208 {208V} outputs 1.5 A continuous AC at 208 V, commercial single-phase and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Conversion efficiency scores 96.3% (#1,770 of 2,343, -0.52 pts vs overall CEC median).

Where Does Solvari Inc: SVR-A10-208 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Solvari Inc: SVR-A10-208 {208V} sits among all 2,343 CEC-listed grid-support inverters. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Solvari Inc: SVR-A10-208 {208V} (303 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolvari Inc: SVR-A: 303 W

What Dataset Percentiles Define Solvari Inc: SVR-A10-208 {208V}?

Relative ranking of Solvari Inc: SVR-A10-208 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Solvari Inc: SVR-A10-208 {208V} Technical ThresholdsPercentile comparison for Solvari Inc: SVR-A10-208 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output303 WCEC Efficiency96.3%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Solvari Inc: SVR-A10-208 {208V}?

Snapshot of Solvari Inc: SVR-A10-208 {208V} efficiency rank (#1,770), OCPD breaker size, MPPT span, and busbar verdict. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Eff #1,770 / 2,343

96.3% CEC Weighted Efficiency

-0.11 pts vs the 96.41% 208 V median; overall power rank #2,239 (303 W, below CEC median; higher than 4.4% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 1.5 A = 1.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 303.0W / 208 V -> 1.5 A | Breaker >= 1.25 * 1.5 = 1.9 A -> 15 A

CEC Inverters.csv for Solvari Inc: SVR-A10-208 {208V}: Paco=303.0 W, Vac=208 V, Vdcmax=55.0 V, Eff=96.3%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Solvari Inc: SVR-A10-208 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Solvari Inc: SVR-A10-208 {208V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Official California Energy Commission (NREL SAM) test parameters for Solvari Inc: SVR-A10-208 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 303 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 55 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 22 V - 55 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 8.98968 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.3% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Solvari Inc: SVR-A10-208 {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Solvari Inc: SVR-A10-208 {208V} at 208 V, commercial single-phase.

Evaluates Solvari Inc: SVR-A10-208 {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Solvari Inc: SVR-A10-208 {208V}?

Minimum and maximum series solar module strings fitting Solvari Inc: SVR-A10-208 {208V} MPPT and 55 V limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to Solvari Inc: SVR-A10-208 {208V}?

Peer 208 V, commercial single-phase CEC inverters near 303 W AC output such as Enphase Energy Inc: IQ8MC-72-2-US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Enphase Energy Inc: IQ8MC-72-2-US {208V}
Enphase Energy Inc
309 W +6 W 208.0 V 45.0 V 96.13%
Enphase Energy Inc: IQ8MC-72-M-DOM-US {208V}
Enphase Energy Inc
310 W +7 W 208.0 V 45.0 V 96.0%
Enphase Energy Inc: IQ8MC-72-M-F-US {208V}
Enphase Energy Inc
310 W +7 W 208.0 V 45.0 V 96.0%
Enphase Energy Inc: IQ8MC-72-M-US {208V}
Enphase Energy Inc
310 W +7 W 208.0 V 45.0 V 96.13%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Solvari Inc: SVR-A10-208 {208V}?

Check Solvari Inc: SVR-A10-208 {208V} (303 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Solvari Inc: SVR-A10-208 {208V}.

Solvari Inc: SVR-A10-208 {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.3%) and MPPT window (22-55 V) directly against Enphase Energy Inc: IQ8MC-72-2-US {208V} (309 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solvari Inc: SVR-A10-208 {208V} by Solvari Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Solvari Inc: SVR-A10-208 {208V} require?

At 303 W continuous AC (208 V, commercial single-phase), continuous current is 1.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Solvari Inc: SVR-A10-208 {208V} require?

At 303 W AC and 208 V, commercial single-phase, continuous line current is 1.5 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Solvari Inc: SVR-A10-208 {208V} compare to Enphase Energy Inc: IQ8MC-72-2-US {208V}?

Solvari Inc: SVR-A10-208 {208V} delivers 303 W AC at 96.3% CEC efficiency with a 55 V DC ceiling, while Enphase Energy Inc: IQ8MC-72-2-US {208V} outputs 309 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.