Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} outputs 289 W AC at 240 V (1.2 A continuous, 15 A OCPD), ranking #2,190 of 2,343 CEC inverters at 95.41% efficiency with a 28-32 V MPPT window and 32 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 289 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 95.41%
How Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Compare Against Peer CEC Listings?
How Chilicon Power LLC Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} compares on 95.41% efficiency, MPPT span, and 120% busbar interconnection.
Chilicon Power LLC certifies Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (grid-tied PV inverter, listed since 2020-02-11) at 289 W AC (5,487 W below the 5,776 W 240 V median). Its 32 V DC ceiling pairs with an MPPT window of 28-32 V (span 4.0 V). Under NEC 690.8/705.12, 125% sizing demands 14 AWG Cu conductors on a 15 A OCPD.
Where Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Fall Across Listed CEC Models?
Position of Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Percentile placement of Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.
95.41% CEC Weighted Efficiency
-1.27 pts vs the 96.68% 240 V median; overall power rank #2,296 (289 W, below CEC median; higher than 2.0% of peers).
15 A Required Backfeed OCPD
125% x 1.2 A = 1.5 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
28 V - 32 V (Max 32 V DC)
Tracking span of 4.0 V; listed since 2020-02-11 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 289.0W / 240 V -> 1.2 A | Breaker >= 1.25 * 1.2 = 1.5 A -> 15 A
CEC Inverters.csv for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}: Paco=289.0 W, Vac=240 V, Vdcmax=32.0 V, Eff=95.41%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 289 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 32 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 28 V - 32 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 10.0967 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2020-02-11 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Check whether Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (15 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which Competing Grid-Support Inverters Compare to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Alternative CEC inverters comparable to Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}, including Aptos Solar Technology LLC: MAC-400 {240V} (382 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC: MAC-400 {240V} Aptos Solar Technology LLC |
382 W | +94 W | 240.0 V | 48.0 V | 96.52% |
| Aptos Solar Technology LLC: MAC-400R {240V} Aptos Solar Technology LLC |
382 W | +94 W | 240.0 V | 48.0 V | 96.52% |
| Altenergy Power System Inc: YC600 {240V} Altenergy Power System Inc |
550 W | +261 W | 240.0 V | 45.0 V | 96.51% |
| Cherry Solution Co Ltd: CMI-600S-SA {240V} Cherry Solution Co Ltd |
604 W | +315 W | 240.0 V | 50.0 V | 96.12% |
What Are the Interconnection Limits and Best-Fit Uses for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}?
Check Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} (289 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 32 V DC on Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}.
Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.41%) and MPPT window (28-32 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} by Chilicon Power LLC covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} require?
At 289 W continuous AC (240 V), continuous current is 1.2 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?
Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} delivers 289 W AC at 95.41% CEC efficiency with a 32 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)