Manufacturer: Chilicon Power LLC Registry: CEC Verified Engineering Specification

Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} outputs 725 W AC at 208 V, commercial single-phase (3.5 A continuous, 15 A OCPD), ranking #2,262 of 2,343 CEC inverters at 94.81% efficiency with a 60-70 V MPPT window and 70 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
725 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
94.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}.

Classified as a grid-tied PV inverter (listed since 2020-02-11), Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} requires 4.4 A design capacity -> 15 A breaker using 14 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 94.81% (-2.01 pts vs overall CEC median) across 2,343 CEC models, while module-level microinverter output eliminates high-voltage dc rooftop strings and connects via a 240v ac trunk circuit.

Where Does Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Fall Across Listed CEC Models?

Output power comparison showing where Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} (725 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChilicon Power LLC: 725 W

What Dataset Percentiles Define Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Relative ranking of Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Technical ThresholdsPercentile comparison for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output725 WCEC Efficiency94.81%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Snapshot of Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} efficiency rank (#2,262), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,262 / 2,343

94.81% CEC Weighted Efficiency

-1.60 pts vs the 96.41% 208 V median; overall power rank #1,893 (725 W, below CEC median; higher than 19.2% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 3.5 A = 4.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

60 V - 70 V (Max 70 V DC)

Tracking span of 10.0 V; listed since 2020-02-11 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 725.0W / 208 V -> 3.5 A | Breaker >= 1.25 * 3.5 = 4.4 A -> 15 A

CEC Inverters.csv for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}: Paco=725.0 W, Vac=208 V, Vdcmax=70.0 V, Eff=94.81%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}.

Official California Energy Commission (NREL SAM) test parameters for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 725 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 70 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 60 V - 70 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.7648 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 94.81% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-02-11 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} at 208 V, commercial single-phase.

Evaluates Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Minimum and maximum series solar module strings fitting Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} MPPT and 70 V limits.

Sampled CEC PV modules aligned within 60.0-70.0 V MPPT and 70.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 1 panel (micro/module) 0.59 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Peer 208 V, commercial single-phase CEC inverters near 725 W AC output such as Aptos Solar Technology LLC: MAC-800 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Aptos Solar Technology LLC: MAC-800 {208V}
Aptos Solar Technology LLC
767 W +42 W 208.0 V 48.0 V 96.12%
Aptos Solar Technology LLC: MAC-800R {208V}
Aptos Solar Technology LLC
767 W +42 W 208.0 V 48.0 V 96.12%
Cherry Solution Co Ltd: CMI-800S-SA {208V}
Cherry Solution Co Ltd
800 W +75 W 208.0 V 50.0 V 95.84%
Cherry Solution Co Ltd: CMI-800S-WA {208V}
Cherry Solution Co Ltd
800 W +75 W 208.0 V 50.0 V 95.84%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}?

Check Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} (725 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 70 V DC on Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}.

Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (94.81%) and MPPT window (60-70 V) directly against Aptos Solar Technology LLC: MAC-800 {208V} (767 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} by Chilicon Power LLC covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} require?

At 725 W continuous AC (208 V, commercial single-phase), continuous current is 3.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} require?

At 725 W AC and 208 V, commercial single-phase, continuous line current is 3.5 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} compare to Aptos Solar Technology LLC: MAC-800 {208V}?

Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V} delivers 725 W AC at 94.81% CEC efficiency with a 70 V DC ceiling, while Aptos Solar Technology LLC: MAC-800 {208V} outputs 767 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.