Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Cherry Solution Co Ltd: CMI-800S-WA {208V} — CEC Inverter Specifications

Manufacturer: Cherry Solution Co Ltd Registry: CEC Verified Engineering Specification

Cherry Solution Co Ltd: CMI-800S-WA {208V} outputs 800 W AC at 208 V, commercial single-phase (3.8 A continuous, 15 A OCPD), ranking #2,053 of 2,343 CEC inverters at 95.84% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
800 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
95.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Cherry Solution Co Ltd: CMI-800S-WA {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,053), 35-50 V MPPT tracking, and panel fit for Cherry Solution Co Ltd: CMI-800S-WA {208V}.

Cherry Solution Co Ltd: CMI-800S-WA {208V} from Cherry Solution Co Ltd outputs 3.8 A continuous AC at 208 V, commercial single-phase (800 W AC, rank #1,869). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 95.84% CEC efficiency compares closely with Aptos Solar Technology LLC: MAC-800 {208V} (767 W). Keep NEC 690.7 winter string Voc below 50 V DC.

Where Does Cherry Solution Co Ltd: CMI-800S-WA {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Cherry Solution Co Ltd: CMI-800S-WA {208V} at 800 W continuous AC output. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Cherry Solution Co Ltd: CMI-800S-WA {208V} (800 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACCherry Solution Co: 800 W

What Dataset Percentiles Define Cherry Solution Co Ltd: CMI-800S-WA {208V}?

Dataset percentiles comparing Cherry Solution Co Ltd: CMI-800S-WA {208V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Cherry Solution Co Ltd: CMI-800S-WA {208V} Technical ThresholdsPercentile comparison for Cherry Solution Co Ltd: CMI-800S-WA {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output800 WCEC Efficiency95.84%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Cherry Solution Co Ltd: CMI-800S-WA {208V}?

Engineering highlights for Cherry Solution Co Ltd: CMI-800S-WA {208V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.

Eff #2,053 / 2,343

95.84% CEC Weighted Efficiency

-0.57 pts vs the 96.41% 208 V median; overall power rank #1,869 (800 W, below CEC median; higher than 20.1% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 3.8 A = 4.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

35 V - 50 V (Max 50 V DC)

Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 800.0W / 208 V -> 3.8 A | Breaker >= 1.25 * 3.8 = 4.8 A -> 15 A

CEC Inverters.csv for Cherry Solution Co Ltd: CMI-800S-WA {208V}: Paco=800.0 W, Vac=208 V, Vdcmax=50.0 V, Eff=95.84%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Cherry Solution Co Ltd: CMI-800S-WA {208V}?

California Energy Commission Solar Equipment List parameters for Cherry Solution Co Ltd: CMI-800S-WA {208V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Cherry Solution Co Ltd: CMI-800S-WA {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 800 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 50 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 35 V - 50 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 19.8734 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.84% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Cherry Solution Co Ltd: CMI-800S-WA {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Cherry Solution Co Ltd: CMI-800S-WA {208V} (15 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Evaluates Cherry Solution Co Ltd: CMI-800S-WA {208V} (15 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Cherry Solution Co Ltd: CMI-800S-WA {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Cherry Solution Co Ltd: CMI-800S-WA {208V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 35.0-50.0 V MPPT and 50.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Cherry Solution Co Ltd: CMI-800S-WA {208V}?

Four alternative CEC inverters matched to Cherry Solution Co Ltd: CMI-800S-WA {208V} (800 W AC), led by Aptos Solar Technology LLC: MAC-800 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Aptos Solar Technology LLC: MAC-800 {208V}
Aptos Solar Technology LLC
767 W -33 W 208.0 V 48.0 V 96.12%
Aptos Solar Technology LLC: MAC-800R {208V}
Aptos Solar Technology LLC
767 W -33 W 208.0 V 48.0 V 96.12%
Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V}
Chilicon Power LLC
725 W -75 W 208.0 V 70.0 V 94.81%
Enphase Energy Inc: IQ8D-72-E-US {208V}
Enphase Energy Inc
640 W -160 W 208.0 V 95.0 V 97.09%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Cherry Solution Co Ltd: CMI-800S-WA {208V}?

Check Cherry Solution Co Ltd: CMI-800S-WA {208V} (800 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on Cherry Solution Co Ltd: CMI-800S-WA {208V}.

Cherry Solution Co Ltd: CMI-800S-WA {208V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (3.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.84%) and MPPT window (35-50 V) directly against Aptos Solar Technology LLC: MAC-800 {208V} (767 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Cherry Solution Co Ltd: CMI-800S-WA {208V} by Cherry Solution Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Cherry Solution Co Ltd: CMI-800S-WA {208V} require?

At 800 W continuous AC (208 V, commercial single-phase), continuous current is 3.8 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Cherry Solution Co Ltd: CMI-800S-WA {208V} require?

At 800 W AC and 208 V, commercial single-phase, continuous line current is 3.8 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Cherry Solution Co Ltd: CMI-800S-WA {208V} compare to Aptos Solar Technology LLC: MAC-800 {208V}?

Cherry Solution Co Ltd: CMI-800S-WA {208V} delivers 800 W AC at 95.84% CEC efficiency with a 50 V DC ceiling, while Aptos Solar Technology LLC: MAC-800 {208V} outputs 767 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.