SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} outputs 8,604 W AC at 240 V (35.9 A continuous, 45 A OCPD), ranking #2,185 of 2,343 CEC inverters at 95.45% efficiency with a 258-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 8,604 W
- AC Voltage
- 240 V
- Min PV Breaker
- 45 A (8 AWG Cu)
- CEC Efficiency
- 95.45%
How Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} Compare Against Peer CEC Listings?
Breaker sizing (45 A), 8 AWG Cu wire rules, and DC input limits for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}.
For NEC 705.12 solar interconnection, SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} outputs 35.9 A continuous AC at 240 V and needs a 45 A backfeed breaker on 8 AWG Cu (75 C). Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 95.45% (#2,185 of 2,343, -1.37 pts vs overall CEC median).
Where Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} Fall Across Listed CEC Models?
Output power comparison showing where SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Relative ranking of SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Snapshot of SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} efficiency rank (#2,185), OCPD breaker size, MPPT span, and busbar verdict.
95.45% CEC Weighted Efficiency
-1.23 pts vs the 96.68% 240 V median; overall power rank #1,062 (8,604 W, top 45.4%; higher than 54.6% of peers).
45 A Required Backfeed OCPD
125% x 35.9 A = 44.9 A -> 45 A standard OCPD using 8 AWG Cu (75 C).
258 V - 500 V (Max 500 V DC)
Tracking span of 242.0 V; listed since 2021-01-21 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 8604.0W / 240 V -> 35.9 A | Breaker >= 1.25 * 35.9 = 44.9 A -> 45 A
CEC Inverters.csv for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}: Paco=8604.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=95.45%.
Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 8,604 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 258 V - 500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 23.7832 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.45% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2021-01-21 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} at 240 V.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 45 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 45 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 45 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 45 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Minimum and maximum series solar module strings fitting SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} MPPT and 500 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 11 panels | 4.67 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 12 panels | 2.4 kW |
Which Competing Grid-Support Inverters Compare to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Peer 240 V CEC inverters near 8,604 W AC output such as ABB: UNO-86-TL-OUTD-S-US-A {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: UNO-86-TL-OUTD-S-US-A {240V} ABB |
8,600 W | -4 W | 240.0 V | 480.0 V | 97.03% |
| ABB: UNO-86-TL-OUTD-S-US-Z-A {240V} ABB |
8,600 W | -4 W | 240.0 V | 480.0 V | 97.03% |
| ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V} ABB |
8,600 W | -4 W | 240.0 V | 480.0 V | 97.03% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
8,596 W | -8 W | 240.0 V | 480.0 V | 97.91% |
What Are the Interconnection Limits and Best-Fit Uses for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}?
Check SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} (8,604 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V}.
SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.45%) and MPPT window (258-500 V) directly against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} by SolaX Power Network Technology (Zhe jiang) Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} require?
At 8,604 W continuous AC (240 V), continuous current is 35.9 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.
Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.
How does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?
SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V} delivers 8,604 W AC at 95.45% CEC efficiency with a 500 V DC ceiling, while ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)