ABB: UNO-86-TL-OUTD-S-US-A {240V} — CEC Inverter Specifications

Manufacturer: ABB Registry: CEC Verified Engineering Specification

ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W AC at 240 V (35.8 A continuous, 45 A OCPD), ranking #975 of 2,343 CEC inverters at 97.03% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,600 W
AC Voltage
240 V
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
97.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ABB: UNO-86-TL-OUTD-S-US-A {240V} Compare Against Peer CEC Listings?

How ABB ABB: UNO-86-TL-OUTD-S-US-A {240V} compares on 97.03% efficiency, MPPT span, and 120% busbar interconnection. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

ABB certifies ABB: UNO-86-TL-OUTD-S-US-A {240V} (grid-tied PV inverter, listed since 2019-02-15) at 8,600 W AC (2,824 W above the 5,776 W 240 V median). Its 480 V DC ceiling pairs with an MPPT window of 200-480 V (span 280.0 V). Under NEC 690.8/705.12, 125% sizing demands 8 AWG Cu conductors on a 45 A OCPD.

Where Does ABB: UNO-86-TL-OUTD-S-US-A {240V} Fall Across Listed CEC Models?

Position of ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W AC) relative to the 7,680 W CEC median inverter. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACABB: UNO-86-TL-OUT: 8,600 W

What Dataset Percentiles Define ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Percentile placement of ABB: UNO-86-TL-OUTD-S-US-A {240V} across AC power class, conversion efficiency, and backfeed breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

ABB: UNO-86-TL-OUTD-S-US-A {240V} Technical ThresholdsPercentile comparison for ABB: UNO-86-TL-OUTD-S-US-A {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,600 WCEC Efficiency97.03%Backfeed Breaker45 A

What Do the Dataset Ranks Show for ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for ABB: UNO-86-TL-OUTD-S-US-A {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #975 / 2,343

97.03% CEC Weighted Efficiency

+0.35 pts vs the 96.68% 240 V median; overall power rank #1,065 (8,600 W, top 45.7%; higher than 54.3% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 35.8 A = 44.8 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8600.0W / 240 V -> 35.8 A | Breaker >= 1.25 * 35.8 = 44.8 A -> 45 A

CEC Inverters.csv for ABB: UNO-86-TL-OUTD-S-US-A {240V}: Paco=8600.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.03%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for ABB: UNO-86-TL-OUTD-S-US-A {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for ABB: UNO-86-TL-OUTD-S-US-A {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,600 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 23.3243 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.03% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-02-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Check whether ABB: UNO-86-TL-OUTD-S-US-A {240V} (45 A breaker) fits without main breaker derate or supply-side taps. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates ABB: UNO-86-TL-OUTD-S-US-A {240V} (45 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 45 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 45 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 45 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 45 A PASS (120% Rule)
225A Bus / 200A Main 70 A 45 A PASS (120% Rule)

Which CEC PV Module Strings Pair With ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Verified cold-weather (-10 C) series module counts matched to ABB: UNO-86-TL-OUTD-S-US-A {240V}'s 480 V DC ceiling. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Alternative CEC inverters comparable to ABB: UNO-86-TL-OUTD-S-US-A {240V}, including Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V} (8,596 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
8,596 W -4 W 240.0 V 480.0 V 97.91%
Base Power Inc: MIN 8200TL-XH-US {240V}
Base Power Inc
8,251 W -349 W 240.0 V 480.0 V 97.7%
Base Power Inc: MIN 9000TL-XH-US {240V}
Base Power Inc
9,063 W +463 W 240.0 V 480.0 V 97.69%
Amensolar Ess Co Ltd: N3H-X80-US {240V}
Amensolar Ess Co Ltd
8,084 W -516 W 240.0 V 430.0 V 97.08%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for ABB: UNO-86-TL-OUTD-S-US-A {240V}?

Check ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: UNO-86-TL-OUTD-S-US-A {240V}.

ABB: UNO-86-TL-OUTD-S-US-A {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.03%) and MPPT window (200-480 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V} (8,596 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: UNO-86-TL-OUTD-S-US-A {240V} by ABB covering breaker sizing, MPPT limits, and 240 V interconnection. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

What breaker and wire size does ABB: UNO-86-TL-OUTD-S-US-A {240V} require?

At 8,600 W continuous AC (240 V), continuous current is 35.8 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

Does ABB: UNO-86-TL-OUTD-S-US-A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

How does ABB: UNO-86-TL-OUTD-S-US-A {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}?

ABB: UNO-86-TL-OUTD-S-US-A {240V} delivers 8,600 W AC at 97.03% CEC efficiency with a 480 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V} outputs 8,596 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.