SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} — CEC Inverter Specifications

Manufacturer: SolaX Power Network Technology (Zhe jiang) Co Ltd Registry: CEC Verified Engineering Specification

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} outputs 7,601 W AC at 240 V (31.7 A continuous, 40 A OCPD), ranking #1,689 of 2,343 CEC inverters at 96.37% efficiency with a 149.7-449.8 V MPPT window and 449.8 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,601 W
AC Voltage
240 V
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
96.37%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,689), 149.7-449.8 V MPPT tracking, and panel fit for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} from SolaX Power Network Technology (Zhe jiang) Co Ltd outputs 31.7 A continuous AC at 240 V (7,601 W AC, rank #1,223). Paired with 8 AWG Cu conductors and a 40 A OCPD, its 96.37% CEC efficiency compares closely with ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W). Keep NEC 690.7 winter string Voc below 449.8 V DC.

Where Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} at 7,601 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (7,601 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolaX Power Networ: 7,601 W

What Dataset Percentiles Define SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Dataset percentiles comparing SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} against 2,343 certified grid-support inverters nationwide.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} Technical ThresholdsPercentile comparison for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,601 WCEC Efficiency96.37%Backfeed Breaker40 A

What Do the Dataset Ranks Show for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Engineering highlights for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility.

Eff #1,689 / 2,343

96.37% CEC Weighted Efficiency

-0.31 pts vs the 96.68% 240 V median; overall power rank #1,223 (7,601 W, below CEC median; higher than 47.8% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 31.7 A = 39.6 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

149.7 V - 449.8 V (Max 449.8 V DC)

Tracking span of 300.1 V; listed since 2026-01-12 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7601.0W / 240 V -> 31.7 A | Breaker >= 1.25 * 31.7 = 39.6 A -> 40 A

CEC Inverters.csv for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}: Paco=7601.0 W, Vac=240 V, Vdcmax=449.8 V, Eff=96.37%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

California Energy Commission Solar Equipment List parameters for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,601 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 449.8 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 149.7 V - 449.8 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 26.2826 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.37% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2026-01-12 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Panelboard and switchgear backfeed allowances for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (40 A OCPD).

Evaluates SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (40 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 40 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 40 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 40 A PASS (120% Rule)
200A Bus / 175A Main 65 A 40 A PASS (120% Rule)
225A Bus / 200A Main 70 A 40 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}.

Sampled CEC PV modules aligned within 149.7-449.8 V MPPT and 449.8 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 4 to 7 panels 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 5 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 5 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 6 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Four alternative CEC inverters matched to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (7,601 W AC), led by ABB: UNO-76-TL-OUTD-S-US-A {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: UNO-76-TL-OUTD-S-US-A {240V}
ABB
7,600 W -1 W 240.0 V 480.0 V 97.05%
ABB: UNO-76-TL-OUTD-S-US-Z-A {240V}
ABB
7,600 W -1 W 240.0 V 480.0 V 97.05%
ABB: UNO-76-TL-OUTD-S-US-Z-M-A {240V}
ABB
7,600 W -1 W 240.0 V 480.0 V 97.05%
Delta Electronics: SOLIVIA 76 NA G4 TL {240V}
Delta Electronics
7,600 W -1 W 240.0 V 500.0 V 97.37%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}?

Check SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} (7,601 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 449.8 V DC on SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V}.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.37%) and MPPT window (149.7-449.8 V) directly against ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} by SolaX Power Network Technology (Zhe jiang) Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} require?

At 7,601 W continuous AC (240 V), continuous current is 31.7 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

How does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} compare to ABB: UNO-76-TL-OUTD-S-US-A {240V}?

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V} delivers 7,601 W AC at 96.37% CEC efficiency with a 449.8 V DC ceiling, while ABB: UNO-76-TL-OUTD-S-US-A {240V} outputs 7,600 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.