Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} — CEC Inverter Specifications

Manufacturer: SolaX Power Network Technology (Zhe jiang) Co Ltd Registry: CEC Verified Engineering Specification

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} outputs 8,613 W AC at 240 V (35.9 A continuous, 45 A OCPD), ranking #2,215 of 2,343 CEC inverters at 95.32% efficiency with a 363-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
8,613 W
AC Voltage
240 V
Min PV Breaker
45 A (8 AWG Cu)
CEC Efficiency
95.32%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,215), 363-430 V MPPT tracking, and panel fit for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}.

Operating at 240 V, SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} converts DC array energy at 95.32% CEC weighted efficiency (below overall CEC median; higher than 5.4% of peers) with a 430 V max DC input and 22.7894 A max input current for NEC 690.7 string safety. Compare this 8,613 W grid-tied PV inverter directly with ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W). Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

Where Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} at 8,613 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (8,613 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolaX Power Networ: 8,613 W

What Dataset Percentiles Define SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

Dataset percentiles comparing SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} against 2,343 certified grid-support inverters nationwide.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} Technical ThresholdsPercentile comparison for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output8,613 WCEC Efficiency95.32%Backfeed Breaker45 A

What Do the Dataset Ranks Show for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

Engineering highlights for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility.

Eff #2,215 / 2,343

95.32% CEC Weighted Efficiency

-1.36 pts vs the 96.68% 240 V median; overall power rank #1,057 (8,613 W, top 45.2%; higher than 54.8% of peers).

NEC 705.12 Check

45 A Required Backfeed OCPD

125% x 35.9 A = 44.9 A -> 45 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

363 V - 430 V (Max 430 V DC)

Tracking span of 67.0 V; listed since 2021-01-21 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 8613.0W / 240 V -> 35.9 A | Breaker >= 1.25 * 35.9 = 44.9 A -> 45 A

CEC Inverters.csv for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}: Paco=8613.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=95.32%.

Result: Min 45 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

California Energy Commission Solar Equipment List parameters for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 8,613 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 430 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 363 V - 430 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 22.7894 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.32% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2021-01-21 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

Panelboard and switchgear backfeed allowances for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (45 A OCPD).

Evaluates SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (45 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 45 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 45 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 45 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 45 A PASS (120% Rule)
225A Bus / 200A Main 70 A 45 A PASS (120% Rule)

Which Competing Grid-Support Inverters Compare to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

Four alternative CEC inverters matched to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (8,613 W AC), led by ABB: UNO-86-TL-OUTD-S-US-A {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: UNO-86-TL-OUTD-S-US-A {240V}
ABB
8,600 W -13 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}
ABB
8,600 W -13 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}
ABB
8,600 W -13 W 240.0 V 480.0 V 97.03%
Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
8,596 W -17 W 240.0 V 480.0 V 97.91%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}?

Check SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} (8,613 W AC, 45 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 45 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V}.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 45 A OCPD breaker (35.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.32%) and MPPT window (363-430 V) directly against ABB: UNO-86-TL-OUTD-S-US-A {240V} (8,600 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} by SolaX Power Network Technology (Zhe jiang) Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} require?

At 8,613 W continuous AC (240 V), continuous current is 35.9 A; 125% NEC 690.8/705.12 sizing requires a 45 A breaker and 8 AWG Cu (75 C) wire.

Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 45 A at 240 V means Needs Derate / Tap 705.11.

How does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} compare to ABB: UNO-86-TL-OUTD-S-US-A {240V}?

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V} delivers 8,613 W AC at 95.32% CEC efficiency with a 430 V DC ceiling, while ABB: UNO-86-TL-OUTD-S-US-A {240V} outputs 8,600 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.