ABB: UNO-76-TL-OUTD-S-US-A {240V} outputs 7,600 W AC at 240 V (31.7 A continuous, 40 A OCPD), ranking #940 of 2,343 CEC inverters at 97.05% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 7,600 W
- AC Voltage
- 240 V
- Min PV Breaker
- 40 A (8 AWG Cu)
- CEC Efficiency
- 97.05%
How Does ABB: UNO-76-TL-OUTD-S-US-A {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for ABB: UNO-76-TL-OUTD-S-US-A {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Ranking #1,225 of 2,343 CEC inverters (below CEC median; higher than 47.1% of peers), ABB: UNO-76-TL-OUTD-S-US-A {240V} is a grid-tied PV inverter delivering 7,600 W continuous AC at 240 V (31.7 A continuous). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 97.05% (+0.37 pts vs the 96.68% 240 V median) against peers like Delta Electronics: SOLIVIA 76 NA G4 TL {240V} (7,600 W).
Where Does ABB: UNO-76-TL-OUTD-S-US-A {240V} Fall Across Listed CEC Models?
Marks ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W AC) across the California Energy Commission inverter AC capacity distribution. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Benchmarks ABB: UNO-76-TL-OUTD-S-US-A {240V} continuous AC output, 97.05% CEC weighted efficiency, and 40 A OCPD breaker demand. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining ABB: UNO-76-TL-OUTD-S-US-A {240V} by ABB. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
97.05% CEC Weighted Efficiency
+0.37 pts vs the 96.68% 240 V median; overall power rank #1,225 (7,600 W, below CEC median; higher than 47.1% of peers).
40 A Required Backfeed OCPD
125% x 31.7 A = 39.6 A -> 40 A standard OCPD using 8 AWG Cu (75 C).
200 V - 480 V (Max 480 V DC)
Tracking span of 280.0 V; listed since 2019-02-15 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 7600.0W / 240 V -> 31.7 A | Breaker >= 1.25 * 31.7 = 39.6 A -> 40 A
CEC Inverters.csv for ABB: UNO-76-TL-OUTD-S-US-A {240V}: Paco=7600.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.05%.
Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for ABB: UNO-76-TL-OUTD-S-US-A {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 7,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 20.607 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.05% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2019-02-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Evaluates ABB: UNO-76-TL-OUTD-S-US-A {240V} (40 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 40 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 40 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 40 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 40 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 40 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Sample PV string lengths aligned within 200-480 V MPPT and 480 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Competing CEC grid-support inverters near 7,600 W AC and 240 V, led by Delta Electronics: SOLIVIA 76 NA G4 TL {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: SOLIVIA 76 NA G4 TL {240V} Delta Electronics |
7,600 W | Tie (0 W) | 240.0 V | 500.0 V | 97.37% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF76K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
7,599 W | -1 W | 240.0 V | 480.0 V | 97.57% |
| Altenergy Power System Inc: ELS-76 {240V} Altenergy Power System Inc |
7,609 W | +9 W | 240.0 V | 60.0 V | 94.31% |
| dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V} dcbel Inc |
7,624 W | +24 W | 240.0 V | 470.0 V | 91.94% |
What Are the Interconnection Limits and Best-Fit Uses for ABB: UNO-76-TL-OUTD-S-US-A {240V}?
Check ABB: UNO-76-TL-OUTD-S-US-A {240V} (7,600 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: UNO-76-TL-OUTD-S-US-A {240V}.
ABB: UNO-76-TL-OUTD-S-US-A {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.05%) and MPPT window (200-480 V) directly against Delta Electronics: SOLIVIA 76 NA G4 TL {240V} (7,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for ABB: UNO-76-TL-OUTD-S-US-A {240V} by ABB covering breaker sizing, MPPT limits, and 240 V interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What breaker and wire size does ABB: UNO-76-TL-OUTD-S-US-A {240V} require?
At 7,600 W continuous AC (240 V), continuous current is 31.7 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.
Does ABB: UNO-76-TL-OUTD-S-US-A {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).
How does ABB: UNO-76-TL-OUTD-S-US-A {240V} compare to Delta Electronics: SOLIVIA 76 NA G4 TL {240V}?
ABB: UNO-76-TL-OUTD-S-US-A {240V} delivers 7,600 W AC at 97.05% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: SOLIVIA 76 NA G4 TL {240V} outputs 7,600 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)