Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} — CEC Inverter Specifications

Manufacturer: SolaX Power Network Technology (Zhe jiang) Co Ltd Registry: CEC Verified Engineering Specification

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} outputs 3,805 W AC at 240 V (15.9 A continuous, 20 A OCPD), ranking #792 of 2,343 CEC inverters at 97.18% efficiency with a 175.4-499.5 V MPPT window and 499.5 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,805 W
AC Voltage
240 V
Min PV Breaker
20 A (12 AWG Cu)
CEC Efficiency
97.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}.

Rated at 3,805 W AC (15.9 A continuous), SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} ranks #792 of 2,343 CEC units at 97.18% efficiency (+0.50 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 20 A circuit is 12 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 499.5 V DC at record local winter lows.

Where Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} Fall Across Listed CEC Models?

Marks SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} (3,805 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} (3,805 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolaX Power Networ: 3,805 W

What Dataset Percentiles Define SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Benchmarks SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} continuous AC output, 97.18% CEC weighted efficiency, and 20 A OCPD breaker demand.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} Technical ThresholdsPercentile comparison for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,805 WCEC Efficiency97.18%Backfeed Breaker20 A

What Do the Dataset Ranks Show for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} by SolaX Power Network Technology (Zhe jiang) Co Ltd.

Eff #792 / 2,343

97.18% CEC Weighted Efficiency

+0.50 pts vs the 96.68% 240 V median; overall power rank #1,643 (3,805 W, below CEC median; higher than 29.7% of peers).

NEC 705.12 Check

20 A Required Backfeed OCPD

125% x 15.9 A = 19.9 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

175.4 V - 499.5 V (Max 499.5 V DC)

Tracking span of 324.1 V; listed since 2026-01-12 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3805.0W / 240 V -> 15.9 A | Breaker >= 1.25 * 15.9 = 19.9 A -> 20 A

CEC Inverters.csv for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}: Paco=3805.0 W, Vac=240 V, Vdcmax=499.5 V, Eff=97.18%.

Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}.

Official California Energy Commission (NREL SAM) test parameters for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,805 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 499.5 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 175.4 V - 499.5 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.5876 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.18% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2026-01-12 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Evaluates SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} (20 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} (20 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 20 A PASS (120% Rule)
150A Bus / 150A Main 30 A 20 A PASS (120% Rule)
200A Bus / 200A Main 40 A 20 A PASS (120% Rule)
200A Bus / 175A Main 65 A 20 A PASS (120% Rule)
225A Bus / 200A Main 70 A 20 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Sample PV string lengths aligned within 175.4-499.5 V MPPT and 499.5 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 175.4-499.5 V MPPT and 499.5 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Competing CEC grid-support inverters near 3,805 W AC and 240 V, led by ABB: PVI-38-OUTD-S-US-A {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-38-OUTD-S-US-A {240V}
ABB
3,800 W -5 W 240.0 V 480.0 V 96.2%
ABB: PVI-38-OUTD-S-US-Z-A {240V}
ABB
3,800 W -5 W 240.0 V 480.0 V 96.2%
ABB: PVI-38-OUTD-S-US-Z-M-A {240V}
ABB
3,800 W -5 W 240.0 V 480.0 V 96.2%
ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V}
ABB
3,800 W -5 W 240.0 V 480.0 V 96.39%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}?

Check SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} (3,805 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 499.5 V DC on SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V}.

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.9 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.18%) and MPPT window (175.4-499.5 V) directly against ABB: PVI-38-OUTD-S-US-A {240V} (3,800 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} by SolaX Power Network Technology (Zhe jiang) Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} require?

At 3,805 W continuous AC (240 V), continuous current is 15.9 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

Does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

How does SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} compare to ABB: PVI-38-OUTD-S-US-A {240V}?

SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V} delivers 3,805 W AC at 97.18% CEC efficiency with a 499.5 V DC ceiling, while ABB: PVI-38-OUTD-S-US-A {240V} outputs 3,800 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.