Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} — CEC Inverter Specifications

Manufacturer: Solaria Corporation Registry: CEC Verified Engineering Specification

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} outputs 349 W AC at 240 V (1.5 A continuous, 15 A OCPD), ranking #1,537 of 2,343 CEC inverters at 96.51% efficiency with a 38-43 V MPPT window and 43 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
349 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,537), 38-43 V MPPT tracking, and panel fit for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} from Solaria Corporation outputs 1.5 A continuous AC at 240 V (349 W AC, rank #2,112). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.51% CEC efficiency compares closely with Aptos Solar Technology LLC: MAC-400 {240V} (382 W). Keep NEC 690.7 winter string Voc below 43 V DC.

Where Does Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} at 349 W continuous AC output. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (349 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolaria Corporatio: 349 W

What Dataset Percentiles Define Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Dataset percentiles comparing Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} against 2,343 certified grid-support inverters nationwide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} Technical ThresholdsPercentile comparison for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output349 WCEC Efficiency96.51%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Engineering highlights for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #1,537 / 2,343

96.51% CEC Weighted Efficiency

-0.17 pts vs the 96.68% 240 V median; overall power rank #2,112 (349 W, below CEC median; higher than 9.7% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 1.5 A = 1.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

38 V - 43 V (Max 43 V DC)

Tracking span of 5.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 348.7W / 240 V -> 1.5 A | Breaker >= 1.25 * 1.5 = 1.9 A -> 15 A

CEC Inverters.csv for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}: Paco=348.7 W, Vac=240 V, Vdcmax=43.0 V, Eff=96.51%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

California Energy Commission Solar Equipment List parameters for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (grid-tied PV inverter) interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 349 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 43 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 38 V - 43 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 8.92155 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.51% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Panelboard and switchgear backfeed allowances for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (15 A OCPD). Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 38.0-43.0 V MPPT and 43.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Four alternative CEC inverters matched to Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (349 W AC), led by Aptos Solar Technology LLC: MAC-400 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Aptos Solar Technology LLC: MAC-400 {240V}
Aptos Solar Technology LLC
382 W +34 W 240.0 V 48.0 V 96.52%
Aptos Solar Technology LLC: MAC-400R {240V}
Aptos Solar Technology LLC
382 W +34 W 240.0 V 48.0 V 96.52%
Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}
Chilicon Power LLC
289 W -60 W 240.0 V 32.0 V 95.41%
Altenergy Power System Inc: YC600 {240V}
Altenergy Power System Inc
550 W +201 W 240.0 V 45.0 V 96.51%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}?

Check Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} (349 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 43 V DC on Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V}.

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.51%) and MPPT window (38-43 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} by Solaria Corporation covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} require?

At 349 W continuous AC (240 V), continuous current is 1.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V} delivers 349 W AC at 96.51% CEC efficiency with a 43 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.