Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} outputs 349 W AC at 240 V (1.5 A continuous, 15 A OCPD), ranking #1,537 of 2,343 CEC inverters at 96.51% efficiency with a 38-43 V MPPT window and 43 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 349 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.51%
How Does Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} Compare Against Peer CEC Listings?
Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}.
For NEC 705.12 solar interconnection, Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} outputs 1.5 A continuous AC at 240 V and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Conversion efficiency scores 96.51% (#1,537 of 2,343, -0.31 pts vs overall CEC median).
Where Does Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} Fall Across Listed CEC Models?
Output power comparison showing where Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} sits among all 2,343 CEC-listed grid-support inverters. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Relative ranking of Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Snapshot of Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} efficiency rank (#1,537), OCPD breaker size, MPPT span, and busbar verdict.
96.51% CEC Weighted Efficiency
-0.17 pts vs the 96.68% 240 V median; overall power rank #2,112 (349 W, below CEC median; higher than 9.7% of peers).
15 A Required Backfeed OCPD
125% x 1.5 A = 1.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
38 V - 43 V (Max 43 V DC)
Tracking span of 5.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 348.7W / 240 V -> 1.5 A | Breaker >= 1.25 * 1.5 = 1.9 A -> 15 A
CEC Inverters.csv for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}: Paco=348.7 W, Vac=240 V, Vdcmax=43.0 V, Eff=96.51%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 349 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 43 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 38 V - 43 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 8.92155 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.51% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} at 240 V. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Minimum and maximum series solar module strings fitting Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} MPPT and 43 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Peer 240 V CEC inverters near 349 W AC output such as Aptos Solar Technology LLC: MAC-400 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC: MAC-400 {240V} Aptos Solar Technology LLC |
382 W | +34 W | 240.0 V | 48.0 V | 96.52% |
| Aptos Solar Technology LLC: MAC-400R {240V} Aptos Solar Technology LLC |
382 W | +34 W | 240.0 V | 48.0 V | 96.52% |
| Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Chilicon Power LLC |
289 W | -60 W | 240.0 V | 32.0 V | 95.41% |
| Altenergy Power System Inc: YC600 {240V} Altenergy Power System Inc |
550 W | +201 W | 240.0 V | 45.0 V | 96.51% |
What Are the Interconnection Limits and Best-Fit Uses for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}?
Check Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} (349 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 43 V DC on Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V}.
Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.51%) and MPPT window (38-43 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} by Solaria Corporation covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} require?
At 349 W continuous AC (240 V), continuous current is 1.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?
Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V} delivers 349 W AC at 96.51% CEC efficiency with a 43 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)