Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolarEdge Technologies Ltd: SE3300x {240V} — CEC Inverter Specifications

Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: SE3300x {240V} outputs 3,251 W AC at 240 V (13.5 A continuous, 20 A OCPD), ranking #666 of 2,343 CEC inverters at 97.33% efficiency with a 370-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,251 W
AC Voltage
240 V
Min PV Breaker
20 A (12 AWG Cu)
CEC Efficiency
97.33%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: SE3300x {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for SolarEdge Technologies Ltd: SE3300x {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rated at 3,251 W AC (13.5 A continuous), SolarEdge Technologies Ltd: SE3300x {240V} ranks #666 of 2,343 CEC units at 97.33% efficiency (+0.65 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 20 A circuit is 12 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 500 V DC at record local winter lows.

Where Does SolarEdge Technologies Ltd: SE3300x {240V} Fall Across Listed CEC Models?

Marks SolarEdge Technologies Ltd: SE3300x {240V} (3,251 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: SE3300x {240V} (3,251 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 3,251 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: SE3300x {240V}?

Benchmarks SolarEdge Technologies Ltd: SE3300x {240V} continuous AC output, 97.33% CEC weighted efficiency, and 20 A OCPD breaker demand.

SolarEdge Technologies Ltd: SE3300x {240V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: SE3300x {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,251 WCEC Efficiency97.33%Backfeed Breaker20 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE3300x {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining SolarEdge Technologies Ltd: SE3300x {240V} by SolarEdge Technologies Ltd.

Eff #666 / 2,343

97.33% CEC Weighted Efficiency

+0.65 pts vs the 96.68% 240 V median; overall power rank #1,722 (3,251 W, below CEC median; higher than 26.5% of peers).

NEC 705.12 Check

20 A Required Backfeed OCPD

125% x 13.5 A = 16.9 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

370 V - 500 V (Max 500 V DC)

Tracking span of 130.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3251.0W / 240 V -> 13.5 A | Breaker >= 1.25 * 13.5 = 16.9 A -> 20 A

CEC Inverters.csv for SolarEdge Technologies Ltd: SE3300x {240V}: Paco=3251.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.33%.

Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE3300x {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for SolarEdge Technologies Ltd: SE3300x {240V}.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: SE3300x {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,251 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 370 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 7.67825 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.33% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: SE3300x {240V}?

Evaluates SolarEdge Technologies Ltd: SE3300x {240V} (20 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates SolarEdge Technologies Ltd: SE3300x {240V} (20 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 20 A PASS (120% Rule)
150A Bus / 150A Main 30 A 20 A PASS (120% Rule)
200A Bus / 200A Main 40 A 20 A PASS (120% Rule)
200A Bus / 175A Main 65 A 20 A PASS (120% Rule)
225A Bus / 200A Main 70 A 20 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SolarEdge Technologies Ltd: SE3300x {240V}?

Sample PV string lengths aligned within 370-500 V MPPT and 500 V DC max at -10 C. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 370.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 11 panels (fixed) 4.67 kW
G-Star Pte Ltd GSN8K66T(H)740WT 740.0 W 54.38 V 9 panels (fixed) 6.66 kW
Hansol Technics Co Ltd HA650-AE-NNEA0 650.0 W 61.2 V 8 panels (fixed) 5.2 kW
Heliene 72M-410 G1 410.0 W 54.77 V 9 panels (fixed) 3.69 kW

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE3300x {240V}?

Competing CEC grid-support inverters near 3,251 W AC and 240 V, led by ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V}
ABB
3,300 W +49 W 240.0 V 480.0 V 96.32%
ABB: UNO-DM-33-TL-PLUS-US-SB-RA-Q {240V}
ABB
3,300 W +49 W 240.0 V 480.0 V 96.32%
ABB: UNO-DM-33-TL-PLUS-US-SE-RA {240V}
ABB
3,300 W +49 W 240.0 V 480.0 V 96.32%
ABB: UNO-DM-33-TL-PLUS-US-SZ-RA {240V}
ABB
3,300 W +49 W 240.0 V 480.0 V 96.32%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE3300x {240V}?

Check SolarEdge Technologies Ltd: SE3300x {240V} (3,251 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on SolarEdge Technologies Ltd: SE3300x {240V}.

SolarEdge Technologies Ltd: SE3300x {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (13.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.33%) and MPPT window (370-500 V) directly against ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V} (3,300 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: SE3300x {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: SE3300x {240V} require?

At 3,251 W continuous AC (240 V), continuous current is 13.5 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

Does SolarEdge Technologies Ltd: SE3300x {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

How does SolarEdge Technologies Ltd: SE3300x {240V} compare to ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V}?

SolarEdge Technologies Ltd: SE3300x {240V} delivers 3,251 W AC at 97.33% CEC efficiency with a 500 V DC ceiling, while ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V} outputs 3,300 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.