Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: SE3000x {240V} outputs 3,010 W AC at 240 V (12.5 A continuous, 20 A OCPD), ranking #526 of 2,343 CEC inverters at 97.56% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,010 W
AC Voltage
240 V
Min PV Breaker
20 A (12 AWG Cu)
CEC Efficiency
97.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: SE3000x {240V} Compare Against Peer CEC Listings?

How SolarEdge Technologies Ltd SolarEdge Technologies Ltd: SE3000x {240V} compares on 97.56% efficiency, MPPT span, and 120% busbar interconnection.

SolarEdge Technologies Ltd certifies SolarEdge Technologies Ltd: SE3000x {240V} (grid-tied PV inverter, listed since 2018-10-15) at 3,010 W AC (2,766 W below the 5,776 W 240 V median). Its 480 V DC ceiling pairs with an MPPT window of 100-480 V (span 380.0 V). Under NEC 690.8/705.12, 125% sizing demands 12 AWG Cu conductors on a 20 A OCPD.

Where Does SolarEdge Technologies Ltd: SE3000x {240V} Fall Across Listed CEC Models?

Position of SolarEdge Technologies Ltd: SE3000x {240V} (3,010 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: SE3000x {240V} (3,010 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 3,010 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: SE3000x {240V}?

Percentile placement of SolarEdge Technologies Ltd: SE3000x {240V} across AC power class, conversion efficiency, and backfeed breaker size.

SolarEdge Technologies Ltd: SE3000x {240V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: SE3000x {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,010 WCEC Efficiency97.56%Backfeed Breaker20 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: SE3000x {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SolarEdge Technologies Ltd: SE3000x {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Eff #526 / 2,343

97.56% CEC Weighted Efficiency

+0.88 pts vs the 96.68% 240 V median; overall power rank #1,728 (3,010 W, below CEC median; higher than 26.2% of peers).

NEC 705.12 Check

20 A Required Backfeed OCPD

125% x 12.5 A = 15.6 A -> 20 A standard OCPD using 12 AWG Cu (75 C).

MPPT Window

100 V - 480 V (Max 480 V DC)

Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3010.0W / 240 V -> 12.5 A | Breaker >= 1.25 * 12.5 = 15.6 A -> 20 A

CEC Inverters.csv for SolarEdge Technologies Ltd: SE3000x {240V}: Paco=3010.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.56%.

Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: SE3000x {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SolarEdge Technologies Ltd: SE3000x {240V}.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: SE3000x {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,010 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 100 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 7.95193 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.56% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: SE3000x {240V}?

Check whether SolarEdge Technologies Ltd: SE3000x {240V} (20 A breaker) fits without main breaker derate or supply-side taps.

Evaluates SolarEdge Technologies Ltd: SE3000x {240V} (20 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 20 A PASS (120% Rule)
150A Bus / 150A Main 30 A 20 A PASS (120% Rule)
200A Bus / 200A Main 40 A 20 A PASS (120% Rule)
200A Bus / 175A Main 65 A 20 A PASS (120% Rule)
225A Bus / 200A Main 70 A 20 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SolarEdge Technologies Ltd: SE3000x {240V}?

Verified cold-weather (-10 C) series module counts matched to SolarEdge Technologies Ltd: SE3000x {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 100.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 3 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 3 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 3 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 4 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: SE3000x {240V}?

Alternative CEC inverters comparable to SolarEdge Technologies Ltd: SE3000x {240V}, including ABB: PVI-30-OUTD-S-US-A {240V} (3,000 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-30-OUTD-S-US-A {240V}
ABB
3,000 W -10 W 240.0 V 480.0 V 96.1%
ABB: PVI-30-OUTD-S-US-Z-A {240V}
ABB
3,000 W -10 W 240.0 V 480.0 V 96.1%
ABB: PVI-30-OUTD-S-US-Z-M-A {240V}
ABB
3,000 W -10 W 240.0 V 480.0 V 96.1%
Base Power Inc: MIN 3000TL-XH-US {240V}
Base Power Inc
3,095 W +85 W 240.0 V 480.0 V 97.2%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: SE3000x {240V}?

Check SolarEdge Technologies Ltd: SE3000x {240V} (3,010 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SolarEdge Technologies Ltd: SE3000x {240V}.

SolarEdge Technologies Ltd: SE3000x {240V} Panel & Wire Spec

Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (12.5 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.56%) and MPPT window (100-480 V) directly against ABB: PVI-30-OUTD-S-US-A {240V} (3,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: SE3000x {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: SE3000x {240V} require?

At 3,010 W continuous AC (240 V), continuous current is 12.5 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.

Does SolarEdge Technologies Ltd: SE3000x {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).

How does SolarEdge Technologies Ltd: SE3000x {240V} compare to ABB: PVI-30-OUTD-S-US-A {240V}?

SolarEdge Technologies Ltd: SE3000x {240V} delivers 3,010 W AC at 97.56% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-30-OUTD-S-US-A {240V} outputs 3,000 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.