Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SolarEdge Technologies Ltd: NX5000T-US {208V} — CEC Inverter Specifications

Manufacturer: SolarEdge Technologies Ltd Registry: CEC Verified Engineering Specification

SolarEdge Technologies Ltd: NX5000T-US {208V} outputs 4,300 W AC at 208 V, commercial single-phase (20.7 A continuous, 30 A OCPD), ranking #14 of 2,343 CEC inverters at 98.89% efficiency with a 370-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,300 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
98.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SolarEdge Technologies Ltd: NX5000T-US {208V} Compare Against Peer CEC Listings?

Breaker sizing (30 A), 10 AWG Cu wire rules, and DC input limits for SolarEdge Technologies Ltd: NX5000T-US {208V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), SolarEdge Technologies Ltd: NX5000T-US {208V} requires 25.9 A design capacity -> 30 A breaker using 10 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 98.89% (+2.07 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, commercial single-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

Where Does SolarEdge Technologies Ltd: NX5000T-US {208V} Fall Across Listed CEC Models?

Output power comparison showing where SolarEdge Technologies Ltd: NX5000T-US {208V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SolarEdge Technologies Ltd: NX5000T-US {208V} (4,300 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolarEdge Technolo: 4,300 W

What Dataset Percentiles Define SolarEdge Technologies Ltd: NX5000T-US {208V}?

Relative ranking of SolarEdge Technologies Ltd: NX5000T-US {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SolarEdge Technologies Ltd: NX5000T-US {208V} Technical ThresholdsPercentile comparison for SolarEdge Technologies Ltd: NX5000T-US {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,300 WCEC Efficiency98.89%Backfeed Breaker30 A

What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: NX5000T-US {208V}?

Snapshot of SolarEdge Technologies Ltd: NX5000T-US {208V} efficiency rank (#14), OCPD breaker size, MPPT span, and busbar verdict.

Eff #14 / 2,343

98.89% CEC Weighted Efficiency

+2.48 pts vs the 96.41% 208 V median; overall power rank #1,602 (4,300 W, below CEC median; higher than 31.6% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 20.7 A = 25.9 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

370 V - 450 V (Max 450 V DC)

Tracking span of 80.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4300.0W / 208 V -> 20.7 A | Breaker >= 1.25 * 20.7 = 25.9 A -> 30 A

CEC Inverters.csv for SolarEdge Technologies Ltd: NX5000T-US {208V}: Paco=4300.0 W, Vac=208 V, Vdcmax=450.0 V, Eff=98.89%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SolarEdge Technologies Ltd: NX5000T-US {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SolarEdge Technologies Ltd: NX5000T-US {208V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for SolarEdge Technologies Ltd: NX5000T-US {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,300 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 450 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 370 V - 450 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.0082 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.89% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SolarEdge Technologies Ltd: NX5000T-US {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SolarEdge Technologies Ltd: NX5000T-US {208V} at 208 V, commercial single-phase.

Evaluates SolarEdge Technologies Ltd: NX5000T-US {208V} (30 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 30 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 30 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 30 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 30 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 30 A PASS (120% Commercial Busbar)

Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: NX5000T-US {208V}?

Peer 208 V, commercial single-phase CEC inverters near 4,300 W AC output such as ABB: PVI-42-OUTD-S-US-A {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-42-OUTD-S-US-A {208V}
ABB
4,200 W -100 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-A {208V}
ABB
4,200 W -100 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-M-A {208V}
ABB
4,200 W -100 W 208.0 V 480.0 V 95.6%
ABB: UNO-DM-46-TL-PLUS-US-SB-RA {208V}
ABB
4,200 W -100 W 208.0 V 480.0 V 95.61%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: NX5000T-US {208V}?

Check SolarEdge Technologies Ltd: NX5000T-US {208V} (4,300 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on SolarEdge Technologies Ltd: NX5000T-US {208V}.

SolarEdge Technologies Ltd: NX5000T-US {208V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.89%) and MPPT window (370-450 V) directly against ABB: PVI-42-OUTD-S-US-A {208V} (4,200 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SolarEdge Technologies Ltd: NX5000T-US {208V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does SolarEdge Technologies Ltd: NX5000T-US {208V} require?

At 4,300 W continuous AC (208 V, commercial single-phase), continuous current is 20.7 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SolarEdge Technologies Ltd: NX5000T-US {208V} require?

At 4,300 W AC and 208 V, commercial single-phase, continuous line current is 20.7 A, requiring a 30 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does SolarEdge Technologies Ltd: NX5000T-US {208V} compare to ABB: PVI-42-OUTD-S-US-A {208V}?

SolarEdge Technologies Ltd: NX5000T-US {208V} delivers 4,300 W AC at 98.89% CEC efficiency with a 450 V DC ceiling, while ABB: PVI-42-OUTD-S-US-A {208V} outputs 4,200 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.