SolarEdge Technologies Ltd: NX13000T-US {240V} outputs 13,000 W AC at 240 V (54.2 A continuous, 70 A OCPD), ranking #86 of 2,343 CEC inverters at 98.47% efficiency with a 370-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 13,000 W
- AC Voltage
- 240 V
- Min PV Breaker
- 70 A (4 AWG Cu)
- CEC Efficiency
- 98.47%
How Does SolarEdge Technologies Ltd: NX13000T-US {240V} Compare Against Peer CEC Listings?
How SolarEdge Technologies Ltd SolarEdge Technologies Ltd: NX13000T-US {240V} compares on 98.47% efficiency, MPPT span, and 120% busbar interconnection.
SolarEdge Technologies Ltd certifies SolarEdge Technologies Ltd: NX13000T-US {240V} (hybrid battery-capable inverter, active in CEC directory) at 13,000 W AC (7,224 W above the 5,776 W 240 V median). Its 450 V DC ceiling pairs with an MPPT window of 370-450 V (span 80.0 V). Under NEC 690.8/705.12, 125% sizing demands 4 AWG Cu conductors on a 70 A OCPD.
Where Does SolarEdge Technologies Ltd: NX13000T-US {240V} Fall Across Listed CEC Models?
Position of SolarEdge Technologies Ltd: NX13000T-US {240V} (13,000 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define SolarEdge Technologies Ltd: NX13000T-US {240V}?
Percentile placement of SolarEdge Technologies Ltd: NX13000T-US {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for SolarEdge Technologies Ltd: NX13000T-US {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for SolarEdge Technologies Ltd: NX13000T-US {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
98.47% CEC Weighted Efficiency
+1.79 pts vs the 96.68% 240 V median; overall power rank #694 (13,000 W, top 29.7%; higher than 70.3% of peers).
70 A Required Backfeed OCPD
125% x 54.2 A = 67.8 A -> 70 A standard OCPD using 4 AWG Cu (75 C).
370 V - 450 V (Max 450 V DC)
Tracking span of 80.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 13000.0W / 240 V -> 54.2 A | Breaker >= 1.25 * 54.2 = 67.8 A -> 70 A
CEC Inverters.csv for SolarEdge Technologies Ltd: NX13000T-US {240V}: Paco=13000.0 W, Vac=240 V, Vdcmax=450.0 V, Eff=98.47%.
Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for SolarEdge Technologies Ltd: NX13000T-US {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for SolarEdge Technologies Ltd: NX13000T-US {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 13,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 450 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 370 V - 450 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 33.424 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.47% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for SolarEdge Technologies Ltd: NX13000T-US {240V}?
Check whether SolarEdge Technologies Ltd: NX13000T-US {240V} (70 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 70 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 70 A | Needs Derate / Tap 705.11 |
| 225A Bus / 200A Main | 70 A | 70 A | PASS (120% Rule) |
Which Competing Grid-Support Inverters Compare to SolarEdge Technologies Ltd: NX13000T-US {240V}?
Alternative CEC inverters comparable to SolarEdge Technologies Ltd: NX13000T-US {240V}, including Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Amensolar Ess Co Ltd: N3H-X12US {240V} Amensolar Ess Co Ltd |
12,214 W | -786 W | 240.0 V | 430.0 V | 96.17% |
| Chint Power Systems America: CPS ECH12KTL/US {240V} Chint Power Systems America |
11,990 W | -1010 W | 240.0 V | 480.0 V | 96.59% |
| Delta Electronics: S12_BDI {240V} Delta Electronics |
11,589 W | -1411 W | 240.0 V | 480.0 V | 96.99% |
| Base Power Inc: MIN 11400TL-XH-US {240V} Base Power Inc |
11,520 W | -1480 W | 240.0 V | 480.0 V | 97.76% |
What Are the Interconnection Limits and Best-Fit Uses for SolarEdge Technologies Ltd: NX13000T-US {240V}?
Check SolarEdge Technologies Ltd: NX13000T-US {240V} (13,000 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on SolarEdge Technologies Ltd: NX13000T-US {240V}.
SolarEdge Technologies Ltd: NX13000T-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (54.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.47%) and MPPT window (370-450 V) directly against Amensolar Ess Co Ltd: N3H-X12US {240V} (12,214 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SolarEdge Technologies Ltd: NX13000T-US {240V} by SolarEdge Technologies Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SolarEdge Technologies Ltd: NX13000T-US {240V} require?
At 13,000 W continuous AC (240 V), continuous current is 54.2 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.
Does SolarEdge Technologies Ltd: NX13000T-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.
How does SolarEdge Technologies Ltd: NX13000T-US {240V} compare to Amensolar Ess Co Ltd: N3H-X12US {240V}?
SolarEdge Technologies Ltd: NX13000T-US {240V} delivers 13,000 W AC at 98.47% CEC efficiency with a 450 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X12US {240V} outputs 12,214 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)