Manufacturer: Shenzhen Growatt New Energy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} outputs 5,864 W AC at 240 V (24.4 A continuous, 35 A OCPD), ranking #1,798 of 2,343 CEC inverters at 96.27% efficiency with a 230-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,864 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
96.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} Compare Against Peer CEC Listings?

Breaker sizing (35 A), 8 AWG Cu wire rules, and DC input limits for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}.

For NEC 705.12 solar interconnection, Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} outputs 24.4 A continuous AC at 240 V and needs a 35 A backfeed breaker on 8 AWG Cu (75 C). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 96.27% (#1,798 of 2,343, -0.55 pts vs overall CEC median).

Where Does Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} (5,864 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 5,864 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Relative ranking of Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,864 WCEC Efficiency96.27%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Snapshot of Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} efficiency rank (#1,798), OCPD breaker size, MPPT span, and busbar verdict.

Eff #1,798 / 2,343

96.27% CEC Weighted Efficiency

-0.41 pts vs the 96.68% 240 V median; overall power rank #1,430 (5,864 W, below CEC median; higher than 39.0% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.4 A = 30.5 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

230 V - 480 V (Max 480 V DC)

Tracking span of 250.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5864.0W / 240 V -> 24.4 A | Breaker >= 1.25 * 24.4 = 30.5 A -> 35 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}: Paco=5864.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.27%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,864 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 230 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 16.0301 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.27% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} at 240 V.

Evaluates Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Minimum and maximum series solar module strings fitting Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} MPPT and 480 V limits.

Sampled CEC PV modules aligned within 230.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Peer 240 V CEC inverters near 5,864 W AC output such as Delta Electronics: E6_BDI {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E6_BDI {240V}
Delta Electronics
5,823 W -41 W 240.0 V 480.0 V 97.63%
Base Power Inc: MIN 6000TL-XH-US {240V}
Base Power Inc
5,918 W +54 W 240.0 V 480.0 V 97.26%
Delta Electronics: E6-TL-US {240V}
Delta Electronics
5,760 W -104 W 240.0 V 480.0 V 97.35%
Delta Electronics: M6-TL-US {240V}
Delta Electronics
5,760 W -104 W 240.0 V 480.0 V 97.37%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}?

Check Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} (5,864 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V}.

Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.27%) and MPPT window (230-480 V) directly against Delta Electronics: E6_BDI {240V} (5,823 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} require?

At 5,864 W continuous AC (240 V), continuous current is 24.4 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} compare to Delta Electronics: E6_BDI {240V}?

Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V} delivers 5,864 W AC at 96.27% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6_BDI {240V} outputs 5,823 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.