Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Schneider Electric USA Inc: CS2200-NA {600V} — CEC Inverter Specifications

Manufacturer: Schneider Electric USA Inc Registry: CEC Verified Engineering Specification

Schneider Electric USA Inc: CS2200-NA {600V} outputs 2,200,000 W AC at 600 V, 3-phase (2117.0 A continuous, 2,650 A OCPD), ranking #792 of 2,343 CEC inverters at 97.18% efficiency with a 905-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,200,000 W
AC Voltage
600 V, 3-phase
Min PV Breaker
2,650 A (parallel Cu feeders)
CEC Efficiency
97.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Schneider Electric USA Inc: CS2200-NA {600V} Compare Against Peer CEC Listings?

Breaker sizing (2,650 A), parallel Cu feeders wire rules, and DC input limits for Schneider Electric USA Inc: CS2200-NA {600V}.

Classified as a grid-tied PV inverter (listed since 2024-04-02), Schneider Electric USA Inc: CS2200-NA {600V} requires 2646.2 A design capacity -> 2,650 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 97.18% (+0.36 pts vs overall CEC median) across 2,343 CEC models, while commercial 600 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (600v) or nec 705.11 supply-side tap.

Where Does Schneider Electric USA Inc: CS2200-NA {600V} Fall Across Listed CEC Models?

Output power comparison showing where Schneider Electric USA Inc: CS2200-NA {600V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Schneider Electric USA Inc: CS2200-NA {600V} (2,200,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSchneider Electric: 2,200,000 W

What Dataset Percentiles Define Schneider Electric USA Inc: CS2200-NA {600V}?

Relative ranking of Schneider Electric USA Inc: CS2200-NA {600V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Schneider Electric USA Inc: CS2200-NA {600V} Technical ThresholdsPercentile comparison for Schneider Electric USA Inc: CS2200-NA {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,200,000 WCEC Efficiency97.18%Backfeed Breaker2,650 A

What Do the Dataset Ranks Show for Schneider Electric USA Inc: CS2200-NA {600V}?

Snapshot of Schneider Electric USA Inc: CS2200-NA {600V} efficiency rank (#792), OCPD breaker size, MPPT span, and busbar verdict.

Eff #792 / 2,343

97.18% CEC Weighted Efficiency

-1.10 pts vs the 98.28% 600 V median; overall power rank #94 (2,200,000 W, top 4.0%; higher than 96.0% of peers).

NEC 705.12 Check

2,650 A Required Backfeed OCPD

125% x 2117.0 A = 2646.2 A -> 2,650 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

905 V - 1,200 V (Max 1,200 V DC)

Tracking span of 295.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2200000.0W / 600 V 3-phase -> 2117.0 A | Breaker >= 1.25 * 2117.0 = 2646.2 A -> 2,650 A

CEC Inverters.csv for Schneider Electric USA Inc: CS2200-NA {600V}: Paco=2200000.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=97.18%.

Result: Min 2,650 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Schneider Electric USA Inc: CS2200-NA {600V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Schneider Electric USA Inc: CS2200-NA {600V}.

Official California Energy Commission (NREL SAM) test parameters for Schneider Electric USA Inc: CS2200-NA {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,200,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 905 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 2147.75 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.18% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-04-02 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Schneider Electric USA Inc: CS2200-NA {600V} (600 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Schneider Electric USA Inc: CS2200-NA {600V} at 600 V, 3-phase.

Evaluates Schneider Electric USA Inc: CS2200-NA {600V} (2650 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 2,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 2,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 2,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 2,650 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 2,650 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Schneider Electric USA Inc: CS2200-NA {600V}?

Minimum and maximum series solar module strings fitting Schneider Electric USA Inc: CS2200-NA {600V} MPPT and 1,200 V limits.

Sampled CEC PV modules aligned within 905.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 28 panels (fixed) 12.32 kW
G-Star Pte Ltd GSN8K66T(H)740WT 740.0 W 54.38 V 22 panels (fixed) 16.28 kW

Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: CS2200-NA {600V}?

Peer 600 V, 3-phase CEC inverters near 2,200,000 W AC output such as Power Electronics: FS2125K {600V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Power Electronics: FS2125K {600V}
Power Electronics
2,201,520 W +1520 W 600.0 V 1200.0 V 97.98%
Power Electronics: FS2000K {600V}
Power Electronics
2,103,416 W -96584 W 600.0 V 1200.0 V 97.83%
Delta Electronics: PCS2328S-XXX-US {600V}
Delta Electronics
2,327,940 W +127940 W 600.0 V 1500.0 V 97.96%
Power Electronics: FS1850CU15 {600V}
Power Electronics
2,020,960 W -179040 W 600.0 V 1200.0 V 97.74%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: CS2200-NA {600V}?

Check Schneider Electric USA Inc: CS2200-NA {600V} (2,200,000 W AC, 2,650 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Schneider Electric USA Inc: CS2200-NA {600V}.

Schneider Electric USA Inc: CS2200-NA {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,650 A OCPD breaker (2117.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.18%) and MPPT window (905-1,200 V) directly against Power Electronics: FS2125K {600V} (2,201,520 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Schneider Electric USA Inc: CS2200-NA {600V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does Schneider Electric USA Inc: CS2200-NA {600V} require?

At 2,200,000 W continuous AC (600 V, 3-phase), continuous current is 2117.0 A; 125% NEC 690.8/705.12 sizing requires a 2,650 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Schneider Electric USA Inc: CS2200-NA {600V} require?

At 2,200,000 W AC and 600 V, 3-phase, continuous line current is 2117.0 A, requiring a 2,650 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does Schneider Electric USA Inc: CS2200-NA {600V} compare to Power Electronics: FS2125K {600V}?

Schneider Electric USA Inc: CS2200-NA {600V} delivers 2,200,000 W AC at 97.18% CEC efficiency with a 1,200 V DC ceiling, while Power Electronics: FS2125K {600V} outputs 2,201,520 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.