Schneider Electric USA Inc: CS1800-NA {575V} — CEC Inverter Specifications

Manufacturer: Schneider Electric USA Inc Registry: CEC Verified Engineering Specification

Schneider Electric USA Inc: CS1800-NA {575V} outputs 1,800,000 W AC at 575 V, 3-phase (1807.4 A continuous, 2,300 A OCPD), ranking #576 of 2,343 CEC inverters at 97.43% efficiency with a 856-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,800,000 W
AC Voltage
575 V, 3-phase
Min PV Breaker
2,300 A (parallel Cu feeders)
CEC Efficiency
97.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Schneider Electric USA Inc: CS1800-NA {575V} Compare Against Peer CEC Listings?

Breaker sizing (2,300 A), parallel Cu feeders wire rules, and DC input limits for Schneider Electric USA Inc: CS1800-NA {575V}.

Classified as a grid-tied PV inverter (listed since 2024-04-02), Schneider Electric USA Inc: CS1800-NA {575V} requires 2259.2 A design capacity -> 2,300 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 97.43% (+0.61 pts vs overall CEC median) across 2,343 CEC models, while commercial 575 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (575v) or nec 705.11 supply-side tap.

Where Does Schneider Electric USA Inc: CS1800-NA {575V} Fall Across Listed CEC Models?

Output power comparison showing where Schneider Electric USA Inc: CS1800-NA {575V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Schneider Electric USA Inc: CS1800-NA {575V} (1,800,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSchneider Electric: 1,800,000 W

What Dataset Percentiles Define Schneider Electric USA Inc: CS1800-NA {575V}?

Relative ranking of Schneider Electric USA Inc: CS1800-NA {575V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Schneider Electric USA Inc: CS1800-NA {575V} Technical ThresholdsPercentile comparison for Schneider Electric USA Inc: CS1800-NA {575V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,800,000 WCEC Efficiency97.43%Backfeed Breaker2,300 A

What Do the Dataset Ranks Show for Schneider Electric USA Inc: CS1800-NA {575V}?

Snapshot of Schneider Electric USA Inc: CS1800-NA {575V} efficiency rank (#576), OCPD breaker size, MPPT span, and busbar verdict.

Eff #576 / 2,343

97.43% CEC Weighted Efficiency

-0.11 pts vs the 97.54% 575 V median; overall power rank #109 (1,800,000 W, top 4.7%; higher than 95.3% of peers).

NEC 705.12 Check

2,300 A Required Backfeed OCPD

125% x 1807.4 A = 2259.2 A -> 2,300 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

856 V - 1,200 V (Max 1,200 V DC)

Tracking span of 344.0 V; listed since 2024-04-02 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 575 V, 3-phase switchgear (200A Bus / 200A Main (575V) to 1,200A Bus / 1,200A Main (575V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1800000.0W / 575 V 3-phase -> 1807.4 A | Breaker >= 1.25 * 1807.4 = 2259.2 A -> 2,300 A

CEC Inverters.csv for Schneider Electric USA Inc: CS1800-NA {575V}: Paco=1800000.0 W, Vac=575 V, Vdcmax=1200.0 V, Eff=97.43%.

Result: Min 2,300 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (575V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Schneider Electric USA Inc: CS1800-NA {575V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Schneider Electric USA Inc: CS1800-NA {575V}.

Official California Energy Commission (NREL SAM) test parameters for Schneider Electric USA Inc: CS1800-NA {575V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,800,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 575 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 856 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1804.16 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.43% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-04-02 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Schneider Electric USA Inc: CS1800-NA {575V} (575 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Schneider Electric USA Inc: CS1800-NA {575V} at 575 V, 3-phase.

Evaluates Schneider Electric USA Inc: CS1800-NA {575V} (2300 A required OCPD at 575 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (575V) 40 A 2,300 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (575V) 80 A 2,300 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (575V) 120 A 2,300 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (575V) 160 A 2,300 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (575V) 240 A 2,300 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Schneider Electric USA Inc: CS1800-NA {575V}?

Minimum and maximum series solar module strings fitting Schneider Electric USA Inc: CS1800-NA {575V} MPPT and 1,200 V limits.

Sampled CEC PV modules aligned within 856.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 26 panels 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 21 to 22 panels 11.33 kW

Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: CS1800-NA {575V}?

Peer 575 V, 3-phase CEC inverters near 1,800,000 W AC output such as SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}
SINENG ELECTRIC CO LTD
1,726,700 W -73300 W 690.0 V 1500.0 V 98.32%
Power Electronics: FS2250CU15O3 {600V}
Power Electronics
2,420,370 W +620370 W 600.0 V 1200.0 V 97.82%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V}
INGETEAM POWER TECHNOLOGY SA
2,467,620 W +667620 W 480.0 V 1300.0 V 96.63%
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W -1238194 W 720.0 V 1500.0 V 98.58%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: CS1800-NA {575V}?

Check Schneider Electric USA Inc: CS1800-NA {575V} (1,800,000 W AC, 2,300 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 575 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (575V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Schneider Electric USA Inc: CS1800-NA {575V}.

Schneider Electric USA Inc: CS1800-NA {575V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 2,300 A OCPD breaker (1807.4 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.43%) and MPPT window (856-1,200 V) directly against SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} (1,726,700 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Schneider Electric USA Inc: CS1800-NA {575V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 575 V, 3-phase interconnection.

What breaker and wire size does Schneider Electric USA Inc: CS1800-NA {575V} require?

At 1,800,000 W continuous AC (575 V, 3-phase), continuous current is 1807.4 A; 125% NEC 690.8/705.12 sizing requires a 2,300 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Schneider Electric USA Inc: CS1800-NA {575V} require?

At 1,800,000 W AC and 575 V, 3-phase, continuous line current is 1807.4 A, requiring a 2,300 A OCPD and 1,200A Bus / 1,200A Main (575V) or NEC 705.11 interconnection.

How does Schneider Electric USA Inc: CS1800-NA {575V} compare to SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}?

Schneider Electric USA Inc: CS1800-NA {575V} delivers 1,800,000 W AC at 97.43% CEC efficiency with a 1,200 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} outputs 1,726,700 W at 575 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.