Schneider Electric USA Inc: CS2000-NA {575V} outputs 2,000,000 W AC at 575 V, 3-phase (2008.2 A continuous, 2,550 A OCPD), ranking #841 of 2,343 CEC inverters at 97.14% efficiency with a 865-1,195 V MPPT window and 1,195 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,000,000 W
- AC Voltage
- 575 V, 3-phase
- Min PV Breaker
- 2,550 A (parallel Cu feeders)
- CEC Efficiency
- 97.14%
How Does Schneider Electric USA Inc: CS2000-NA {575V} Compare Against Peer CEC Listings?
CEC efficiency rank (#841), 865-1,195 V MPPT tracking, and panel fit for Schneider Electric USA Inc: CS2000-NA {575V}.
Schneider Electric USA Inc: CS2000-NA {575V} from Schneider Electric USA Inc outputs 2008.2 A continuous AC at 575 V, 3-phase (2,000,000 W AC, rank #104). Paired with parallel Cu feeders conductors and a 2,550 A OCPD, its 97.14% CEC efficiency compares closely with SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} (1,726,700 W). Keep NEC 690.7 winter string Voc below 1,195 V DC.
Where Does Schneider Electric USA Inc: CS2000-NA {575V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Schneider Electric USA Inc: CS2000-NA {575V} at 2,000,000 W continuous AC output. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define Schneider Electric USA Inc: CS2000-NA {575V}?
Dataset percentiles comparing Schneider Electric USA Inc: CS2000-NA {575V} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Schneider Electric USA Inc: CS2000-NA {575V}?
Engineering highlights for Schneider Electric USA Inc: CS2000-NA {575V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
97.14% CEC Weighted Efficiency
-0.40 pts vs the 97.54% 575 V median; overall power rank #104 (2,000,000 W, top 4.4%; higher than 95.6% of peers).
2,550 A Required Backfeed OCPD
125% x 2008.2 A = 2510.2 A -> 2,550 A standard OCPD using parallel Cu feeders (75 C).
865 V - 1,195 V (Max 1,195 V DC)
Tracking span of 330.0 V; listed since 2024-04-02 (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 575 V, 3-phase switchgear (200A Bus / 200A Main (575V) to 1,200A Bus / 1,200A Main (575V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2000000.0W / 575 V 3-phase -> 2008.2 A | Breaker >= 1.25 * 2008.2 = 2510.2 A -> 2,550 A
CEC Inverters.csv for Schneider Electric USA Inc: CS2000-NA {575V}: Paco=2000000.0 W, Vac=575 V, Vdcmax=1195.0 V, Eff=97.14%.
Result: Min 2,550 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (575V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for Schneider Electric USA Inc: CS2000-NA {575V}?
California Energy Commission Solar Equipment List parameters for Schneider Electric USA Inc: CS2000-NA {575V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,000,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 575 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,195 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 865 V - 1,195 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1975.86 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.14% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Schneider Electric USA Inc: CS2000-NA {575V} (575 V, 3-phase)?
Panelboard and switchgear backfeed allowances for Schneider Electric USA Inc: CS2000-NA {575V} (2,550 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (575V) | 40 A | 2,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (575V) | 80 A | 2,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (575V) | 120 A | 2,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (575V) | 160 A | 2,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (575V) | 240 A | 2,550 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With Schneider Electric USA Inc: CS2000-NA {575V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Schneider Electric USA Inc: CS2000-NA {575V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 21 panels (fixed) | 12.39 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 28 panels | 12.32 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 26 panels (fixed) | 11.05 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 22 panels (fixed) | 11.33 kW |
Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: CS2000-NA {575V}?
Four alternative CEC inverters matched to Schneider Electric USA Inc: CS2000-NA {575V} (2,000,000 W AC), led by SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | -273300 W | 690.0 V | 1500.0 V | 98.32% |
| Power Electronics: FS2250CU15O3 {600V} Power Electronics |
2,420,370 W | +420370 W | 600.0 V | 1200.0 V | 97.82% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} INGETEAM POWER TECHNOLOGY SA |
2,467,620 W | +467620 W | 480.0 V | 1300.0 V | 96.63% |
| Sungrow Power Supply Co Ltd: SG3150U {630V} Sungrow Power Supply Co Ltd |
3,154,300 W | +1154300 W | 630.0 V | 1300.0 V | 97.49% |
What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: CS2000-NA {575V}?
Check Schneider Electric USA Inc: CS2000-NA {575V} (2,000,000 W AC, 2,550 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 575 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (575V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,195 V DC on Schneider Electric USA Inc: CS2000-NA {575V}.
Schneider Electric USA Inc: CS2000-NA {575V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 2,550 A OCPD breaker (2008.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.14%) and MPPT window (865-1,195 V) directly against SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} (1,726,700 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Schneider Electric USA Inc: CS2000-NA {575V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 575 V, 3-phase interconnection.
What breaker and wire size does Schneider Electric USA Inc: CS2000-NA {575V} require?
At 2,000,000 W continuous AC (575 V, 3-phase), continuous current is 2008.2 A; 125% NEC 690.8/705.12 sizing requires a 2,550 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does Schneider Electric USA Inc: CS2000-NA {575V} require?
At 2,000,000 W AC and 575 V, 3-phase, continuous line current is 2008.2 A, requiring a 2,550 A OCPD and 1,200A Bus / 1,200A Main (575V) or NEC 705.11 interconnection.
How does Schneider Electric USA Inc: CS2000-NA {575V} compare to SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}?
Schneider Electric USA Inc: CS2000-NA {575V} delivers 2,000,000 W AC at 97.14% CEC efficiency with a 1,195 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} outputs 1,726,700 W at 575 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)