Schneider Electric USA Inc: CS1666-1-NA {575V} outputs 1,666,000 W AC at 575 V, 3-phase (1672.9 A continuous, 2,100 A OCPD), ranking #532 of 2,343 CEC inverters at 97.54% efficiency with a 856-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,666,000 W
- AC Voltage
- 575 V, 3-phase
- Min PV Breaker
- 2,100 A (parallel Cu feeders)
- CEC Efficiency
- 97.54%
How Does Schneider Electric USA Inc: CS1666-1-NA {575V} Compare Against Peer CEC Listings?
Breaker sizing (2,100 A), parallel Cu feeders wire rules, and DC input limits for Schneider Electric USA Inc: CS1666-1-NA {575V}.
Classified as a grid-tied PV inverter (listed since 2024-04-02), Schneider Electric USA Inc: CS1666-1-NA {575V} requires 2091.1 A design capacity -> 2,100 A breaker using parallel Cu feeders copper at 75 C terminals. Weighted efficiency sits at 97.54% (+0.72 pts vs overall CEC median) across 2,343 CEC models, while commercial 575 v, 3-phase switchgear interconnection uses 1,200a bus / 1,200a main (575v) or nec 705.11 supply-side tap.
Where Does Schneider Electric USA Inc: CS1666-1-NA {575V} Fall Across Listed CEC Models?
Output power comparison showing where Schneider Electric USA Inc: CS1666-1-NA {575V} sits among all 2,343 CEC-listed grid-support inverters.
What Dataset Percentiles Define Schneider Electric USA Inc: CS1666-1-NA {575V}?
Relative ranking of Schneider Electric USA Inc: CS1666-1-NA {575V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for Schneider Electric USA Inc: CS1666-1-NA {575V}?
Snapshot of Schneider Electric USA Inc: CS1666-1-NA {575V} efficiency rank (#532), OCPD breaker size, MPPT span, and busbar verdict.
97.54% CEC Weighted Efficiency
equal to the 97.54% 575 V median; overall power rank #120 (1,666,000 W, top 5.2%; higher than 94.8% of peers).
2,100 A Required Backfeed OCPD
125% x 1672.9 A = 2091.1 A -> 2,100 A standard OCPD using parallel Cu feeders (75 C).
856 V - 1,200 V (Max 1,200 V DC)
Tracking span of 344.0 V; listed since 2024-04-02 (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 575 V, 3-phase switchgear (200A Bus / 200A Main (575V) to 1,200A Bus / 1,200A Main (575V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1666000.0W / 575 V 3-phase -> 1672.9 A | Breaker >= 1.25 * 1672.9 = 2091.1 A -> 2,100 A
CEC Inverters.csv for Schneider Electric USA Inc: CS1666-1-NA {575V}: Paco=1666000.0 W, Vac=575 V, Vdcmax=1200.0 V, Eff=97.54%.
Result: Min 2,100 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (575V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for Schneider Electric USA Inc: CS1666-1-NA {575V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Schneider Electric USA Inc: CS1666-1-NA {575V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,666,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 575 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 856 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 1667.91 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.54% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-04-02 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Schneider Electric USA Inc: CS1666-1-NA {575V} (575 V, 3-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for Schneider Electric USA Inc: CS1666-1-NA {575V} at 575 V, 3-phase.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (575V) | 40 A | 2,100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (575V) | 80 A | 2,100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (575V) | 120 A | 2,100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (575V) | 160 A | 2,100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (575V) | 240 A | 2,100 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With Schneider Electric USA Inc: CS1666-1-NA {575V}?
Minimum and maximum series solar module strings fitting Schneider Electric USA Inc: CS1666-1-NA {575V} MPPT and 1,200 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 20 to 21 panels | 12.39 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 26 to 28 panels | 12.32 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 25 to 26 panels | 11.05 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 21 to 22 panels | 11.33 kW |
Which Competing Grid-Support Inverters Compare to Schneider Electric USA Inc: CS1666-1-NA {575V}?
Peer 575 V, 3-phase CEC inverters near 1,666,000 W AC output such as SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} SINENG ELECTRIC CO LTD |
1,726,700 W | +60700 W | 690.0 V | 1500.0 V | 98.32% |
| Power Electronics: FS2250CU15O3 {600V} Power Electronics |
2,420,370 W | +754370 W | 600.0 V | 1200.0 V | 97.82% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V} INGETEAM POWER TECHNOLOGY SA |
2,467,620 W | +801620 W | 480.0 V | 1300.0 V | 96.63% |
| EPC Power Corp: 50-200100 {720V} EPC Power Corp |
561,806 W | -1104194 W | 720.0 V | 1500.0 V | 98.58% |
What Are the Interconnection Limits and Best-Fit Uses for Schneider Electric USA Inc: CS1666-1-NA {575V}?
Check Schneider Electric USA Inc: CS1666-1-NA {575V} (1,666,000 W AC, 2,100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 575 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (575V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Schneider Electric USA Inc: CS1666-1-NA {575V}.
Schneider Electric USA Inc: CS1666-1-NA {575V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 2,100 A OCPD breaker (1672.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.54%) and MPPT window (856-1,200 V) directly against SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} (1,726,700 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Schneider Electric USA Inc: CS1666-1-NA {575V} by Schneider Electric USA Inc covering breaker sizing, MPPT limits, and 575 V, 3-phase interconnection.
What breaker and wire size does Schneider Electric USA Inc: CS1666-1-NA {575V} require?
At 1,666,000 W continuous AC (575 V, 3-phase), continuous current is 1672.9 A; 125% NEC 690.8/705.12 sizing requires a 2,100 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does Schneider Electric USA Inc: CS1666-1-NA {575V} require?
At 1,666,000 W AC and 575 V, 3-phase, continuous line current is 1672.9 A, requiring a 2,100 A OCPD and 1,200A Bus / 1,200A Main (575V) or NEC 705.11 interconnection.
How does Schneider Electric USA Inc: CS1666-1-NA {575V} compare to SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V}?
Schneider Electric USA Inc: CS1666-1-NA {575V} delivers 1,666,000 W AC at 97.54% CEC efficiency with a 1,200 V DC ceiling, while SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V} outputs 1,726,700 W at 575 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)