Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Lite-On Technology Corporation: IN-HP5113US {240V} — CEC Inverter Specifications

Manufacturer: Lite-On Technology Corporation Registry: CEC Verified Engineering Specification

Lite-On Technology Corporation: IN-HP5113US {240V} outputs 11,361 W AC at 240 V (47.3 A continuous, 60 A OCPD), ranking #792 of 2,343 CEC inverters at 97.18% efficiency with a 257-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,361 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.18%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lite-On Technology Corporation: IN-HP5113US {240V} Compare Against Peer CEC Listings?

Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Lite-On Technology Corporation: IN-HP5113US {240V}.

For NEC 705.12 solar interconnection, Lite-On Technology Corporation: IN-HP5113US {240V} outputs 47.3 A continuous AC at 240 V and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 97.18% (#792 of 2,343, +0.36 pts vs overall CEC median).

Where Does Lite-On Technology Corporation: IN-HP5113US {240V} Fall Across Listed CEC Models?

Output power comparison showing where Lite-On Technology Corporation: IN-HP5113US {240V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Lite-On Technology Corporation: IN-HP5113US {240V} (11,361 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACLite-On Technology: 11,361 W

What Dataset Percentiles Define Lite-On Technology Corporation: IN-HP5113US {240V}?

Relative ranking of Lite-On Technology Corporation: IN-HP5113US {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Lite-On Technology Corporation: IN-HP5113US {240V} Technical ThresholdsPercentile comparison for Lite-On Technology Corporation: IN-HP5113US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,361 WCEC Efficiency97.18%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Lite-On Technology Corporation: IN-HP5113US {240V}?

Snapshot of Lite-On Technology Corporation: IN-HP5113US {240V} efficiency rank (#792), OCPD breaker size, MPPT span, and busbar verdict.

Eff #792 / 2,343

97.18% CEC Weighted Efficiency

+0.50 pts vs the 96.68% 240 V median; overall power rank #796 (11,361 W, top 34.0%; higher than 66.0% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 47.3 A = 59.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

257 V - 500 V (Max 500 V DC)

Tracking span of 243.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11361.0W / 240 V -> 47.3 A | Breaker >= 1.25 * 47.3 = 59.1 A -> 60 A

CEC Inverters.csv for Lite-On Technology Corporation: IN-HP5113US {240V}: Paco=11361.0 W, Vac=240 V, Vdcmax=500.0 V, Eff=97.18%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Lite-On Technology Corporation: IN-HP5113US {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Lite-On Technology Corporation: IN-HP5113US {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for Lite-On Technology Corporation: IN-HP5113US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,361 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 257 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 30.7642 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.18% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Lite-On Technology Corporation: IN-HP5113US {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Lite-On Technology Corporation: IN-HP5113US {240V} at 240 V. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates Lite-On Technology Corporation: IN-HP5113US {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Lite-On Technology Corporation: IN-HP5113US {240V}?

Minimum and maximum series solar module strings fitting Lite-On Technology Corporation: IN-HP5113US {240V} MPPT and 500 V limits.

Sampled CEC PV modules aligned within 257.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Lite-On Technology Corporation: IN-HP5113US {240V}?

Peer 240 V CEC inverters near 11,361 W AC output such as Chint Power Systems America: CPS ECH114KTL/US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH114KTL/US {240V}
Chint Power Systems America
11,360 W -1 W 240.0 V 480.0 V 96.53%
Altenergy Power System Inc: ELS-114 {240V}
Altenergy Power System Inc
11,415 W +54 W 240.0 V 60.0 V 93.08%
Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}
Dyness Digital Energy Technology Co LTD
11,498 W +137 W 240.0 V 500.0 V 96.41%
Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}
Dyness Digital Energy Technology Co LTD
11,519 W +158 W 240.0 V 490.0 V 96.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Lite-On Technology Corporation: IN-HP5113US {240V}?

Check Lite-On Technology Corporation: IN-HP5113US {240V} (11,361 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Lite-On Technology Corporation: IN-HP5113US {240V}.

Lite-On Technology Corporation: IN-HP5113US {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.18%) and MPPT window (257-500 V) directly against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Lite-On Technology Corporation: IN-HP5113US {240V} by Lite-On Technology Corporation covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Lite-On Technology Corporation: IN-HP5113US {240V} require?

At 11,361 W continuous AC (240 V), continuous current is 47.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Lite-On Technology Corporation: IN-HP5113US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Lite-On Technology Corporation: IN-HP5113US {240V} compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?

Lite-On Technology Corporation: IN-HP5113US {240V} delivers 11,361 W AC at 97.18% CEC efficiency with a 500 V DC ceiling, while Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.