Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Lite-On Technology Corporation: IN-HP5123US {120V} — CEC Inverter Specifications

Manufacturer: Lite-On Technology Corporation Registry: CEC Verified Engineering Specification

Lite-On Technology Corporation: IN-HP5123US {120V} outputs 9,019 W AC at 120 V (75.2 A continuous, 100 A OCPD), ranking #2,051 of 2,343 CEC inverters at 95.85% efficiency with a 285-500 V MPPT window and 500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,019 W
AC Voltage
120 V
Min PV Breaker
100 A (3 AWG Cu)
CEC Efficiency
95.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lite-On Technology Corporation: IN-HP5123US {120V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 120 V grid-support overview for Lite-On Technology Corporation: IN-HP5123US {120V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Ranking #1,014 of 2,343 CEC inverters (top 43.6%; higher than 56.4% of peers), Lite-On Technology Corporation: IN-HP5123US {120V} is a hybrid battery-capable inverter delivering 9,019 W continuous AC at 120 V (75.2 A continuous). Its 100 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Weighted CEC efficiency reaches 95.85% (+1.12 pts vs the 94.73% 120 V median) against peers like MPP SOLAR INC: LVX 12KW WP {120V} (9,019 W).

Where Does Lite-On Technology Corporation: IN-HP5123US {120V} Fall Across Listed CEC Models?

Marks Lite-On Technology Corporation: IN-HP5123US {120V} (9,019 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Lite-On Technology Corporation: IN-HP5123US {120V} (9,019 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACLite-On Technology: 9,019 W

What Dataset Percentiles Define Lite-On Technology Corporation: IN-HP5123US {120V}?

Benchmarks Lite-On Technology Corporation: IN-HP5123US {120V} continuous AC output, 95.85% CEC weighted efficiency, and 100 A OCPD breaker demand.

Lite-On Technology Corporation: IN-HP5123US {120V} Technical ThresholdsPercentile comparison for Lite-On Technology Corporation: IN-HP5123US {120V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,019 WCEC Efficiency95.85%Backfeed Breaker100 A

What Do the Dataset Ranks Show for Lite-On Technology Corporation: IN-HP5123US {120V}?

Four key NEC 705.12 and California Energy Commission metrics defining Lite-On Technology Corporation: IN-HP5123US {120V} by Lite-On Technology Corporation.

Eff #2,051 / 2,343

95.85% CEC Weighted Efficiency

+1.12 pts vs the 94.73% 120 V median; overall power rank #1,014 (9,019 W, top 43.6%; higher than 56.4% of peers).

NEC 705.12 Check

100 A Required Backfeed OCPD

125% x 75.2 A = 94.0 A -> 100 A standard OCPD using 3 AWG Cu (75 C).

MPPT Window

285 V - 500 V (Max 500 V DC)

Tracking span of 215.0 V; listed since 2025-04-21 (hybrid battery-capable inverter).

Panel Fit (240V)

120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9018.6W / 120 V -> 75.2 A | Breaker >= 1.25 * 75.2 = 94.0 A -> 100 A

CEC Inverters.csv for Lite-On Technology Corporation: IN-HP5123US {120V}: Paco=9018.6 W, Vac=120 V, Vdcmax=500.0 V, Eff=95.85%.

Result: Min 100 A breaker & 3 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

What Are the Published CEC Specifications for Lite-On Technology Corporation: IN-HP5123US {120V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Lite-On Technology Corporation: IN-HP5123US {120V}.

Official California Energy Commission (NREL SAM) test parameters for Lite-On Technology Corporation: IN-HP5123US {120V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,019 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 120 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 285 V - 500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 26.1354 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.85% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-04-21 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Lite-On Technology Corporation: IN-HP5123US {120V}?

Evaluates Lite-On Technology Corporation: IN-HP5123US {120V} (100 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Lite-On Technology Corporation: IN-HP5123US {120V} (100 A required OCPD at 120 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 100 A 120V AC Coupled / Dedicated Transformer
150A Bus / 150A Main 30 A 100 A 120V AC Coupled / Dedicated Transformer
200A Bus / 200A Main 40 A 100 A 120V AC Coupled / Dedicated Transformer
200A Bus / 175A Main 65 A 100 A 120V AC Coupled / Dedicated Transformer
225A Bus / 200A Main 70 A 100 A 120V AC Coupled / Dedicated Transformer

Which CEC PV Module Strings Pair With Lite-On Technology Corporation: IN-HP5123US {120V}?

Sample PV string lengths aligned within 285-500 V MPPT and 500 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 285.0-500.0 V MPPT and 500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 to 11 panels 4.67 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 10 to 12 panels 2.4 kW

Which Competing Grid-Support Inverters Compare to Lite-On Technology Corporation: IN-HP5123US {120V}?

Competing CEC grid-support inverters near 9,019 W AC and 120 V, led by MPP SOLAR INC: LVX 12KW WP {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
MPP SOLAR INC: LVX 12KW WP {120V}
MPP SOLAR INC
9,019 W Tie (0 W) 120.0 V 500.0 V 95.82%
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {120V}
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP
9,019 W Tie (0 W) 120.0 V 500.0 V 95.82%
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 12KW {120V}
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP
9,019 W Tie (0 W) 120.0 V 500.0 V 95.82%
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Premium {120V}
VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP
10,029 W +1010 W 120.0 V 500.0 V 94.92%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Lite-On Technology Corporation: IN-HP5123US {120V}?

Check Lite-On Technology Corporation: IN-HP5123US {120V} (9,019 W AC, 100 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 100 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 500 V DC on Lite-On Technology Corporation: IN-HP5123US {120V}.

Lite-On Technology Corporation: IN-HP5123US {120V} Panel & Wire Spec

Size 75 C copper conductors at 3 AWG Cu on a 100 A OCPD breaker (75.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.85%) and MPPT window (285-500 V) directly against MPP SOLAR INC: LVX 12KW WP {120V} (9,019 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Lite-On Technology Corporation: IN-HP5123US {120V} by Lite-On Technology Corporation covering breaker sizing, MPPT limits, and 120 V interconnection.

What breaker and wire size does Lite-On Technology Corporation: IN-HP5123US {120V} require?

At 9,019 W continuous AC (120 V), continuous current is 75.2 A; 125% NEC 690.8/705.12 sizing requires a 100 A breaker and 3 AWG Cu (75 C) wire.

Does Lite-On Technology Corporation: IN-HP5123US {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 100 A at 120 V means 120V AC Coupled / Dedicated Transformer.

How does Lite-On Technology Corporation: IN-HP5123US {120V} compare to MPP SOLAR INC: LVX 12KW WP {120V}?

Lite-On Technology Corporation: IN-HP5123US {120V} delivers 9,019 W AC at 95.85% CEC efficiency with a 500 V DC ceiling, while MPP SOLAR INC: LVX 12KW WP {120V} outputs 9,019 W at 120 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.