Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Altenergy Power System Inc: QS1A {240V} — CEC Inverter Specifications

Manufacturer: Altenergy Power System Inc Registry: CEC Verified Engineering Specification

Altenergy Power System Inc: QS1A {240V} outputs 1,516 W AC at 240 V (6.3 A continuous, 15 A OCPD), ranking #2,097 of 2,343 CEC inverters at 95.75% efficiency with a 30-52 V MPPT window and 52 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,516 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
95.75%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Altenergy Power System Inc: QS1A {240V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Altenergy Power System Inc: QS1A {240V}.

For NEC 705.12 solar interconnection, Altenergy Power System Inc: QS1A {240V} outputs 6.3 A continuous AC at 240 V and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 95.75% (#2,097 of 2,343, -1.07 pts vs overall CEC median).

Where Does Altenergy Power System Inc: QS1A {240V} Fall Across Listed CEC Models?

Output power comparison showing where Altenergy Power System Inc: QS1A {240V} sits among all 2,343 CEC-listed grid-support inverters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Altenergy Power System Inc: QS1A {240V} (1,516 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACAltenergy Power Sy: 1,516 W

What Dataset Percentiles Define Altenergy Power System Inc: QS1A {240V}?

Relative ranking of Altenergy Power System Inc: QS1A {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Altenergy Power System Inc: QS1A {240V} Technical ThresholdsPercentile comparison for Altenergy Power System Inc: QS1A {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,516 WCEC Efficiency95.75%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Altenergy Power System Inc: QS1A {240V}?

Snapshot of Altenergy Power System Inc: QS1A {240V} efficiency rank (#2,097), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,097 / 2,343

95.75% CEC Weighted Efficiency

-0.93 pts vs the 96.68% 240 V median; overall power rank #1,790 (1,516 W, below CEC median; higher than 23.6% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 6.3 A = 7.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

30 V - 52 V (Max 52 V DC)

Tracking span of 22.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1516.0W / 240 V -> 6.3 A | Breaker >= 1.25 * 6.3 = 7.9 A -> 15 A

CEC Inverters.csv for Altenergy Power System Inc: QS1A {240V}: Paco=1516.0 W, Vac=240 V, Vdcmax=52.0 V, Eff=95.75%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Altenergy Power System Inc: QS1A {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Altenergy Power System Inc: QS1A {240V}.

Official California Energy Commission (NREL SAM) test parameters for Altenergy Power System Inc: QS1A {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,516 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 52 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 30 V - 52 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 38.6174 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.75% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Altenergy Power System Inc: QS1A {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Altenergy Power System Inc: QS1A {240V} at 240 V.

Evaluates Altenergy Power System Inc: QS1A {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Altenergy Power System Inc: QS1A {240V}?

Minimum and maximum series solar module strings fitting Altenergy Power System Inc: QS1A {240V} MPPT and 52 V limits.

Sampled CEC PV modules aligned within 30.0-52.0 V MPPT and 52.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Altenergy Power System Inc: QS1A {240V}?

Peer 240 V CEC inverters near 1,516 W AC output such as Anker Innovations Limited: MI80H {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Anker Innovations Limited: MI80H {240V}
Anker Innovations Limited
1,068 W -448 W 240.0 V 43.0 V 96.73%
Cherry Solution Co Ltd: CMI-1000S-SA {240V}
Cherry Solution Co Ltd
1,062 W -454 W 240.0 V 50.0 V 96.33%
Cherry Solution Co Ltd: CMI-1000S-WA {240V}
Cherry Solution Co Ltd
1,062 W -454 W 240.0 V 50.0 V 96.33%
Anker Innovations Limited: MI80 {240V}
Anker Innovations Limited
896 W -620 W 240.0 V 43.0 V 97.02%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Altenergy Power System Inc: QS1A {240V}?

Check Altenergy Power System Inc: QS1A {240V} (1,516 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 52 V DC on Altenergy Power System Inc: QS1A {240V}.

Altenergy Power System Inc: QS1A {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (6.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.75%) and MPPT window (30-52 V) directly against Anker Innovations Limited: MI80H {240V} (1,068 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Altenergy Power System Inc: QS1A {240V} by Altenergy Power System Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Altenergy Power System Inc: QS1A {240V} require?

At 1,516 W continuous AC (240 V), continuous current is 6.3 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Altenergy Power System Inc: QS1A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Altenergy Power System Inc: QS1A {240V} compare to Anker Innovations Limited: MI80H {240V}?

Altenergy Power System Inc: QS1A {240V} delivers 1,516 W AC at 95.75% CEC efficiency with a 52 V DC ceiling, while Anker Innovations Limited: MI80H {240V} outputs 1,068 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.