ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} outputs 3,000 W AC at 208 V, commercial single-phase (14.4 A continuous, 20 A OCPD), ranking #2,081 of 2,343 CEC inverters at 95.8% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,000 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 20 A (12 AWG Cu)
- CEC Efficiency
- 95.8%
How Does ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#2,081), 200-480 V MPPT tracking, and panel fit for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} from ABB outputs 14.4 A continuous AC at 208 V, commercial single-phase (3,000 W AC, rank #1,729). Paired with 12 AWG Cu conductors and a 20 A OCPD, its 95.8% CEC efficiency compares closely with Delta Electronics: SOLIVIA 38 NA G4 TL {208V} (3,320 W). Keep NEC 690.7 winter string Voc below 480 V DC.
Where Does ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} at 3,000 W continuous AC output. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
Dataset percentiles comparing ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
Engineering highlights for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} covering efficiency, 12 AWG Cu feeder, and panel compatibility. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
95.8% CEC Weighted Efficiency
-0.61 pts vs the 96.41% 208 V median; overall power rank #1,729 (3,000 W, below CEC median; higher than 25.3% of peers).
20 A Required Backfeed OCPD
125% x 14.4 A = 18.0 A -> 20 A standard OCPD using 12 AWG Cu (75 C).
200 V - 480 V (Max 480 V DC)
Tracking span of 280.0 V; listed since 2020-08-21 (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3000.0W / 208 V -> 14.4 A | Breaker >= 1.25 * 14.4 = 18.0 A -> 20 A
CEC Inverters.csv for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}: Paco=3000.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=95.8%.
Result: Min 20 A breaker & 12 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
California Energy Commission Solar Equipment List parameters for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} (grid-tied PV inverter) interconnection. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 9.21045 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.8% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2020-08-21 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} (20 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 20 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 20 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 20 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 20 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 20 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
Four alternative CEC inverters matched to ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} (3,000 W AC), led by Delta Electronics: SOLIVIA 38 NA G4 TL {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: SOLIVIA 38 NA G4 TL {208V} Delta Electronics |
3,320 W | +320 W | 208.0 V | 500.0 V | 97.23% |
| Delta Electronics: M4-TL-US {208V} Delta Electronics |
3,330 W | +330 W | 208.0 V | 480.0 V | 97.27% |
| Delta Electronics: E4_BDI {208V} Delta Electronics |
3,341 W | +341 W | 208.0 V | 480.0 V | 97.43% |
| Delta Electronics: E4-TL-US {208V} Delta Electronics |
3,360 W | +360 W | 208.0 V | 480.0 V | 97.64% |
What Are the Interconnection Limits and Best-Fit Uses for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}?
Check ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} (3,000 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V}.
ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} Panel & Wire Spec
Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (14.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.8%) and MPPT window (200-480 V) directly against Delta Electronics: SOLIVIA 38 NA G4 TL {208V} (3,320 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} by ABB covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} require?
At 3,000 W continuous AC (208 V, commercial single-phase), continuous current is 14.4 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} require?
At 3,000 W AC and 208 V, commercial single-phase, continuous line current is 14.4 A, requiring a 20 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} compare to Delta Electronics: SOLIVIA 38 NA G4 TL {208V}?
ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} delivers 3,000 W AC at 95.8% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: SOLIVIA 38 NA G4 TL {208V} outputs 3,320 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)