Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

ABB: UNO-76-TL-OUTD-S-US-A {277V} — CEC Inverter Specifications

Manufacturer: ABB Registry: CEC Verified Engineering Specification

ABB: UNO-76-TL-OUTD-S-US-A {277V} outputs 7,600 W AC at 480Y/277 V, 3-phase (9.1 A continuous, 15 A OCPD), ranking #732 of 2,343 CEC inverters at 97.24% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,600 W
AC Voltage
480Y/277 V, 3-phase
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
97.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ABB: UNO-76-TL-OUTD-S-US-A {277V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for ABB: UNO-76-TL-OUTD-S-US-A {277V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

For NEC 705.12 solar interconnection, ABB: UNO-76-TL-OUTD-S-US-A {277V} outputs 9.1 A continuous AC at 480Y/277 V, 3-phase and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.24% (#732 of 2,343, +0.42 pts vs overall CEC median).

Where Does ABB: UNO-76-TL-OUTD-S-US-A {277V} Fall Across Listed CEC Models?

Output power comparison showing where ABB: UNO-76-TL-OUTD-S-US-A {277V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where ABB: UNO-76-TL-OUTD-S-US-A {277V} (7,600 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACABB: UNO-76-TL-OUT: 7,600 W

What Dataset Percentiles Define ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Relative ranking of ABB: UNO-76-TL-OUTD-S-US-A {277V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

ABB: UNO-76-TL-OUTD-S-US-A {277V} Technical ThresholdsPercentile comparison for ABB: UNO-76-TL-OUTD-S-US-A {277V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,600 WCEC Efficiency97.24%Backfeed Breaker15 A

What Do the Dataset Ranks Show for ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Snapshot of ABB: UNO-76-TL-OUTD-S-US-A {277V} efficiency rank (#732), OCPD breaker size, MPPT span, and busbar verdict. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #732 / 2,343

97.24% CEC Weighted Efficiency

+0.42 pts vs the 96.82% 277 V median; overall power rank #1,225 (7,600 W, below CEC median; higher than 47.1% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 9.1 A = 11.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2019-02-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480Y/277 V, 3-phase switchgear (200A Bus / 200A Main (277V) to 1,200A Bus / 1,200A Main (277V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7600.0W / 480 V 3-phase -> 9.1 A | Breaker >= 1.25 * 9.1 = 11.4 A -> 15 A

CEC Inverters.csv for ABB: UNO-76-TL-OUTD-S-US-A {277V}: Paco=7600.0 W, Vac=277 V, Vdcmax=480.0 V, Eff=97.24%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (277V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for ABB: UNO-76-TL-OUTD-S-US-A {277V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for ABB: UNO-76-TL-OUTD-S-US-A {277V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,600 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480Y/277 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 20.5669 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.24% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2019-02-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to ABB: UNO-76-TL-OUTD-S-US-A {277V} (480Y/277 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for ABB: UNO-76-TL-OUTD-S-US-A {277V} at 480Y/277 V, 3-phase. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates ABB: UNO-76-TL-OUTD-S-US-A {277V} (15 A required OCPD at 480Y/277 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (277V) 40 A 15 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (277V) 80 A 15 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (277V) 120 A 15 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (277V) 160 A 15 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (277V) 240 A 15 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Minimum and maximum series solar module strings fitting ABB: UNO-76-TL-OUTD-S-US-A {277V} MPPT and 480 V limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Peer 480Y/277 V, 3-phase CEC inverters near 7,600 W AC output such as Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
8,137 W +537 W 277.0 V 550.0 V 97.79%
Shenzhen Growatt New Energy Co Ltd: GROWATT 7000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
7,016 W -584 W 277.0 V 480.0 V 96.5%
Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
6,080 W -1520 W 277.0 V 550.0 V 97.0%
Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {277V}
Shenzhen Growatt New Energy Co Ltd
9,169 W +1569 W 277.0 V 550.0 V 97.75%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for ABB: UNO-76-TL-OUTD-S-US-A {277V}?

Check ABB: UNO-76-TL-OUTD-S-US-A {277V} (7,600 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480Y/277 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (277V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: UNO-76-TL-OUTD-S-US-A {277V}.

ABB: UNO-76-TL-OUTD-S-US-A {277V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (9.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.24%) and MPPT window (200-480 V) directly against Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V} (8,137 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: UNO-76-TL-OUTD-S-US-A {277V} by ABB covering breaker sizing, MPPT limits, and 480Y/277 V, 3-phase interconnection.

What breaker and wire size does ABB: UNO-76-TL-OUTD-S-US-A {277V} require?

At 7,600 W continuous AC (480Y/277 V, 3-phase), continuous current is 9.1 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does ABB: UNO-76-TL-OUTD-S-US-A {277V} require?

At 7,600 W AC and 480Y/277 V, 3-phase, continuous line current is 9.1 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (277V) or NEC 705.11 interconnection.

How does ABB: UNO-76-TL-OUTD-S-US-A {277V} compare to Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V}?

ABB: UNO-76-TL-OUTD-S-US-A {277V} delivers 7,600 W AC at 97.24% CEC efficiency with a 480 V DC ceiling, while Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V} outputs 8,137 W at 480Y/277 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.