ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P is a 285.0 W STC (255.7 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.68% efficiency, 44.5 V Voc at 25 C, and 49.64 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 285.0 W
- PTC Wattage
- 255.7 W
- Voc @ 25C
- 44.5 V
- Efficiency
- 14.68%
How Does ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P Compare Against Peer CEC Listings?
Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from ZNSHINE PV-TECH Co Ltd and peers, ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P stands 125.0 W below the 410.0 W Mono-c-Si median and typical 89.7% PTC-to-STC thermal output (255.7 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Mid-range 44.5 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P Fall Across Listed CEC Models?
Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P (285.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
285.0 W STC · Higher Than 17.3%
285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.68% Aperture Efficiency
Power density 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.64 V at -10 C (595.7 V string) and 51.11 V at -20 C (11 max).
29 Panels = 8,265 W STC
Occupies 56.3 m2 (606 sq ft) producing 7,415 W PTC; NEC 690.8 OCPD floor is 13.23 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.5 * (1 + (-0.33/100) * (-10 - 25)) = 49.64 V | OCPD = 1.56 * 8.48 = 13.23 A
Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P: Voc=44.5 V, beta_Voc=-0.33%/C, Isc=8.48 A, STC=285.0 W, Area=1.941 m2.
Result: 12 panels max on 600 V (595.7 V); 29 panels for 8 kW (606 sq ft).
What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 285.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 255.7 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.48 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 7.85 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.68% (1.941 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.27 kW | 460 sq ft | $1,569 | $2,654 |
| 8 kW Class | 29 | 8.27 kW | 606 sq ft | $2,070 | $3,500 |
| 10 kW Class | 36 | 10.26 kW | 752 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?
Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| ZNSHINE PV-TECH Co Ltd ZXP6-72-275/P | 275.0 W | 246.5 W | 44.42 V | 35.9 V | 14.17% |
| ZNSHINE PV-TECH Co Ltd ZXP6-72-280/P | 280.0 W | 251.1 W | 44.5 V | 36.1 V | 14.42% |
| ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P | 285.0 W | 255.7 W | 44.5 V | 36.3 V | 14.68% |
| ZNSHINE PV-TECH Co Ltd ZXP6-72-290/P | 290.0 W | 260.3 W | 44.6 V | 36.5 V | 14.94% |
| ZNSHINE PV-TECH Co Ltd ZXP6-72-295/P | 295.0 W | 264.9 W | 44.82 V | 36.8 V | 15.2% |
How Many ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P (49.64 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.11 V | 11 panels | 562.2 V | 19 panels |
| -10 C (14 F) | 49.64 V | 12 panels | 595.7 V | 20 panels |
| 0 C (32 F) | 48.17 V | 12 panels | 578.0 V | 20 panels |
| 25 C (77 F STC) | 44.5 V | 13 panels | 578.5 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P in nameplate wattage and Voc, starting with AXITEC AC-285P/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-285P/156-72S AXITEC |
285.0 W | Tie (0 W) | 44.51 V | 14.72% | 90.0% |
| Gintung Energy ASEC-285G6M Gintung Energy |
285.0 W | Tie (0 W) | 44.53 V | 14.57% | 89.5% |
| Centrosolar America DP72 285 Centrosolar America |
285.0 W | Tie (0 W) | 44.32 V | 14.66% | 88.5% |
| Gintung Energy ASEC-285G6S Gintung Energy |
285.0 W | Tie (0 W) | 44.69 V | 14.57% | 89.7% |
What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Evaluate ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P (285.0 W STC, 44.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P reaches 51.11 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
- 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P 8 kW Residential Fit
Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-285P/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 255.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P?
Multiplying ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P's 8.48 A short-circuit current by 1.56 equals 13.23 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.64 V cold Voc at 14 F and handles 8.48 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P at 12 panels on 600 V.
Is ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)