ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} is a 420.0 W STC (391.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 19.53% efficiency, 49.1 V Voc at 25 C, and 53.55 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 391.9 W
- Voc @ 25C
- 49.1 V
- Efficiency
- 19.53%
How Does ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} (Mono-c-Si) residential solar systems.
ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} delivers 195.3 W/m2 (0.38 percentage points below 19.91% CEC median) and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 20 panels (463 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 54.82 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with DualSun SAS DualSun 420M-144-01 (420.0 W).
Where Does ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} Fall Across Listed CEC Models?
Comparison of ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} (420.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}?
Relative ranking of ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}?
Summary of ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.53% Aperture Efficiency
Power density 195.3 W/m2 (0.38 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.55 V at -10 C (589.0 V string) and 54.82 V at -20 C (10 max).
20 Panels = 8,400 W STC
Occupies 43.0 m2 (463 sq ft) producing 7,838 W PTC; NEC 690.8 OCPD floor is 17.22 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.1 * (1 + (-0.259/100) * (-10 - 25)) = 53.55 V | OCPD = 1.56 * 11.04 = 17.22 A
Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}: Voc=49.1 V, beta_Voc=-0.259%/C, Isc=11.04 A, STC=420.0 W, Area=2.15 m2.
Result: 11 panels max on 600 V (589.0 V); 20 panels for 8 kW (463 sq ft).
What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}?
Complete CEC test sheet for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} including Isc (11.04 A), Voc (49.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 391.9 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.2 V / 10.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.53% (2.15 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 347 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 463 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 555 sq ft | $2,523 | $4,266 |
How Many ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} (49.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.82 V | 10 panels | 548.2 V | 18 panels |
| -10 C (14 F) | 53.55 V | 11 panels | 589.0 V | 18 panels |
| 0 C (32 F) | 52.28 V | 11 panels | 575.1 V | 19 panels |
| 25 C (77 F STC) | 49.1 V | 12 panels | 589.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}?
Four comparable CEC modules such as DualSun SAS DualSun 420M-144-01 (420.0 W) for side-by-side solar quote checks. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | -10.0 W | 49.21 V | 20.4% | 94.0% |
| AXITEC AC-410MH/144V AXITEC |
410.0 W | -10.0 W | 48.91 V | 20.71% | 93.5% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | -10.0 W | 49.3 V | 21.03% | 93.0% |
What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht}?
Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} (420.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} reaches 54.82 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 463 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (463 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} 8 kW Residential Fit
Needs 20 modules (463 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DualSun SAS DualSun 420M-144-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} panels fit on a 600 V winter solar string?
At -10 C (14 F), ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} cold Voc rises from 49.1 V to 53.55 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (589.0 V).
How much roof area does an 8 kW array of ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} need?
An 8 kW DC system uses 20 ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} modules (8,400 W STC / 7,838 W PTC), covering roughly 463 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} compare against DualSun SAS DualSun 420M-144-01?
ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht} outputs 420.0 W STC (49.1 V Voc, rank #7,910 of 21,677), while DualSun SAS DualSun 420M-144-01 delivers 420.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)