Skip to main content
WireAndSun
Calculators
CEC PV Module

ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M — CEC Solar Module Specifications

Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M is a 285.0 W STC (250.3 W PTC) Mono-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.68% efficiency, 45.38 V Voc at 25 C, and 51.54 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
250.3 W
Voc @ 25C
45.38 V
Efficiency
14.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M Compare Against Peer CEC Listings?

How ZNSHINE PV-TECH Co Ltd ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M handles rooftop heat (250.3 W PTC), 8 kW sizing, and cold winter string voltage.

ZNSHINE PV-TECH Co Ltd builds the ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (Mono-c-Si) as a compact residential or specialty off-grid module delivering 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-285G6S (285.0 W), this model holds typical 87.8% PTC-to-STC thermal output (250.3 W real-world rating). Mid-range 45.38 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.35 A overcurrent floor served by a 15 A breaker.

Where Does ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M Fall Across Listed CEC Models?

Where ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 285.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Percentile placement of ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M across power density (146.8 W/m2), thermal retention, and nameplate STC wattage.

ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention87.8%Module Efficiency14.68%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Four critical engineering numbers homeowners and solar installers check first when reviewing ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M specifications.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,210

14.68% Aperture Efficiency

Power density 146.8 W/m2 (5.23 percentage points below 19.91% CEC median). PTC/STC ratio: 87.8% (rank #21,465).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.54 V at -10 C (566.9 V string) and 53.3 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.3 m2 (606 sq ft) producing 7,259 W PTC; NEC 690.8 OCPD floor is 13.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.38 * (1 + (-0.388/100) * (-10 - 25)) = 51.54 V | OCPD = 1.56 * 8.56 = 13.35 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M: Voc=45.38 V, beta_Voc=-0.388%/C, Isc=8.56 A, STC=285.0 W, Area=1.941 m2.

Result: 11 panels max on 600 V (566.9 V); 29 panels for 8 kW (606 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.3 W (87.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.6 V / 7.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.388 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.68% (1.941 m2) Array roof footprint density
Cell Count & Technology 12 cells (Mono-c-Si) Monofacial backsheet

How Many ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 460 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 606 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 752 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?

All closely matched ZNSHINE PV-TECH Co Ltd wattages and cosmetic trims sharing the ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M architecture.

Sibling CEC listings grouped into the ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
ZNSHINE PV-TECH Co Ltd ZXM6-72-275/M 275.0 W 241.2 W 44.64 V 36.2 V 14.17%
ZNSHINE PV-TECH Co Ltd ZXM6-72-280/M 280.0 W 245.8 W 45.01 V 36.5 V 14.42%
ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M 285.0 W 250.3 W 45.38 V 36.6 V 14.68%
ZNSHINE PV-TECH Co Ltd ZXM6-72-290/M 290.0 W 254.8 W 45.77 V 36.8 V 14.94%
ZNSHINE PV-TECH Co Ltd ZXM6-72-295/M 295.0 W 259.4 W 46.0 V 37.0 V 15.2%

How Many ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M Modules Fit in a Cold-Weather String?

Maximum series module counts for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.38V and beta_Voc=-0.388%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.3 V 11 panels 586.3 V 18 panels
-10 C (14 F) 51.54 V 11 panels 566.9 V 19 panels
0 C (32 F) 49.78 V 12 panels 597.4 V 20 panels
25 C (77 F STC) 45.38 V 13 panels 589.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Alternative CEC solar modules from competing brands near ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (285.0 W), including Gintung Energy ASEC-285G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W Tie (0 W) 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W Tie (0 W) 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W Tie (0 W) 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M (285.0 W STC, 45.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M reaches 53.3 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 606 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (606 sq ft).
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M 8 kW Residential Fit

Needs 29 modules (606 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M?

Multiplying ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M's 8.56 A short-circuit current by 1.56 equals 13.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.54 V cold Voc at 14 F and handles 8.56 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M at 11 panels on 600 V.

Is ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.