ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M is a 260.0 W STC (233.2 W PTC) Mono-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.88% efficiency, 38.4 V Voc at 25 C, and 42.7 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 233.2 W
- Voc @ 25C
- 38.4 V
- Efficiency
- 15.88%
How Does ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M Compare Against Peer CEC Listings?
Solar engineering breakdown for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from ZNSHINE PV-TECH Co Ltd and peers, ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M stands 150.0 W below the 410.0 W Mono-c-Si median and typical 89.7% PTC-to-STC thermal output (233.2 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 38.4 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M Fall Across Listed CEC Models?
Distribution marker showing ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Dataset percentiles tracking ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Benchmark highlights for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.88% Aperture Efficiency
Power density 158.8 W/m2 (4.03 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.7 V at -10 C (597.8 V string) and 43.93 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.7 m2 (546 sq ft) producing 7,229 W PTC; NEC 690.8 OCPD floor is 13.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.4 * (1 + (-0.32/100) * (-10 - 25)) = 42.7 V | OCPD = 1.56 * 8.95 = 13.96 A
Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M: Voc=38.4 V, beta_Voc=-0.32%/C, Isc=8.95 A, STC=260.0 W, Area=1.637 m2.
Result: 14 panels max on 600 V (597.8 V); 31 panels for 8 kW (546 sq ft).
What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Official CEC datasheet figures for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 233.2 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.72 V / 8.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.88% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 10 cells (Mono-c-Si) | Monofacial backsheet |
How Many ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 423 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 546 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 687 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This ZNSHINE PV-TECH Co Ltd Series?
Consolidated ZNSHINE PV-TECH Co Ltd wattage variants sharing the ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| ZNSHINE PV-TECH Co Ltd ZXM6-60-250/M | 250.0 W | 220.5 W | 38.2 V | 30.5 V | 15.27% |
| ZNSHINE PV-TECH Co Ltd ZXM6-60-255/M | 255.0 W | 225.1 W | 38.3 V | 30.6 V | 15.58% |
| ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M | 260.0 W | 233.2 W | 38.4 V | 30.72 V | 15.88% |
| ZNSHINE PV-TECH Co Ltd ZXM6-60-265/M | 265.0 W | 237.8 W | 38.5 V | 30.84 V | 16.19% |
| ZNSHINE PV-TECH Co Ltd ZXM6-60-270/M | 270.0 W | 242.4 W | 38.6 V | 30.97 V | 16.5% |
How Many ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M (42.7 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.93 V | 13 panels | 571.1 V | 22 panels |
| -10 C (14 F) | 42.7 V | 14 panels | 597.8 V | 23 panels |
| 0 C (32 F) | 41.47 V | 14 panels | 580.6 V | 24 panels |
| 25 C (77 F STC) | 38.4 V | 15 panels | 576.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Competing CEC solar panels closest to ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M in nameplate wattage and Voc, starting with BYD Company Limited BYD 260P6C-30.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD 260P6C-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.98% | 90.4% |
| BYD Company Limited BYD260P6K-30 BYD Company Limited |
260.0 W | Tie (0 W) | 38.38 V | 15.95% | 91.7% |
| Centrosolar America DP60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.28 V | 15.86% | 90.2% |
| Centrosolar America DM60 260 Centrosolar America |
260.0 W | Tie (0 W) | 38.2 V | 15.86% | 90.8% |
What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M (260.0 W STC, 38.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M reaches 43.93 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M 8 kW Residential Fit
Needs 31 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare BYD Company Limited BYD 260P6C-30.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 233.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M?
Multiplying ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M's 8.95 A short-circuit current by 1.56 equals 13.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.7 V cold Voc at 14 F and handles 8.95 A Isc; string inverters cap ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M at 14 panels on 600 V.
Is ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)