Skip to main content
WireAndSun
Calculators
CEC PV Module

Zebra Energy ZBR-235P — CEC Solar Module Specifications

Manufacturer: Zebra Energy Registry: CEC Verified Engineering Specification

Zebra Energy ZBR-235P is a 235.0 W STC (212.2 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.39% efficiency, 36.2 V Voc at 25 C, and 40.99 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
212.2 W
Voc @ 25C
36.2 V
Efficiency
14.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zebra Energy ZBR-235P Compare Against Peer CEC Listings?

How Zebra Energy Zebra Energy ZBR-235P handles rooftop heat (212.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Zebra Energy ZBR-235P exhibits 8.8 A short-circuit current, requiring a 13.73 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (43.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.2 m2 for an 8 kW system (43 panels for 10 kW). Lower 36.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Zebra Energy ZBR-235P Fall Across Listed CEC Models?

Where Zebra Energy ZBR-235P (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zebra Energy ZBR-235P (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZebra Energy ZBR-2: 235.0 W

What Dataset Percentiles Define Zebra Energy ZBR-235P?

Percentile placement of Zebra Energy ZBR-235P across power density (143.9 W/m2), thermal retention, and nameplate STC wattage.

Zebra Energy ZBR-235P Engineering BenchmarksPercentile comparison of Zebra Energy ZBR-235P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.3%Module Efficiency14.39%

What Do the Dataset Ranks Show for Zebra Energy ZBR-235P?

Four critical engineering numbers homeowners and solar installers check first when reviewing Zebra Energy ZBR-235P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,540

14.39% Aperture Efficiency

Power density 143.9 W/m2 (5.52 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.99 V at -10 C (573.9 V string) and 42.36 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.2 m2 (615 sq ft) producing 7,427 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.2 * (1 + (-0.378/100) * (-10 - 25)) = 40.99 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for Zebra Energy ZBR-235P: Voc=36.2 V, beta_Voc=-0.378%/C, Isc=8.8 A, STC=235.0 W, Area=1.633 m2.

Result: 14 panels max on 600 V (573.9 V); 35 panels for 8 kW (615 sq ft).

What Are the Published CEC Specifications for Zebra Energy ZBR-235P?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Zebra Energy ZBR-235P.

Official California Energy Commission (NREL SAM) test parameters for Zebra Energy ZBR-235P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 212.2 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.7 V / 7.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.378 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.39% (1.633 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Zebra Energy ZBR-235P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Zebra Energy ZBR-235P (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 457 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 615 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 756 sq ft $2,530 $4,279

How Many Zebra Energy ZBR-235P Modules Fit in a Cold-Weather String?

Maximum series module counts for Zebra Energy ZBR-235P from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.2V and beta_Voc=-0.378%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.36 V 14 panels 593.0 V 23 panels
-10 C (14 F) 40.99 V 14 panels 573.9 V 24 panels
0 C (32 F) 39.62 V 15 panels 594.3 V 25 panels
25 C (77 F STC) 36.2 V 16 panels 579.2 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Zebra Energy ZBR-235P?

Alternative CEC solar modules from competing brands near Zebra Energy ZBR-235P (235.0 W), including Changzhou Nesl Solartech DJ-235P-ST15.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Changzhou Nesl Solartech DJ-235P-ST15
Changzhou Nesl Solartech
235.0 W Tie (0 W) 36.2 V 14.39% 90.3%
Anhui Rinengzhongtian Semiconductor Development QJP235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.1 V 14.44% 89.3%
Anhui Rinengzhongtian Semiconductor Development QJM235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.65 V 14.44% 90.0%
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zebra Energy ZBR-235P?

Evaluate Zebra Energy ZBR-235P (235.0 W STC, 36.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zebra Energy ZBR-235P reaches 42.36 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 615 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (615 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zebra Energy ZBR-235P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zebra Energy ZBR-235P 8 kW Residential Fit

Needs 35 modules (615 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Changzhou Nesl Solartech DJ-235P-ST15.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 212.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zebra Energy ZBR-235P by Zebra Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Zebra Energy ZBR-235P PTC wattage (212.2 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 212.2 W PTC (90.3% retention) across Zebra Energy ZBR-235P's 1.633 m2 aperture.

Who should skip Zebra Energy ZBR-235P on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Zebra Energy ZBR-235P panels (615 sq ft) leave unusable roof gaps vs. Changzhou Nesl Solartech DJ-235P-ST15.

What is the 1,000 V commercial string limit for Zebra Energy ZBR-235P?

On 1,000 V commercial inverters at -10 C (40.99 V cold Voc), Zebra Energy ZBR-235P fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Zebra Energy ZBR-235P.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.