Yingli Energy (China) YL260P-29b is a 260.0 W STC (235.0 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.01% efficiency, 44.6 V Voc at 25 C, and 49.6 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 235.0 W
- Voc @ 25C
- 44.6 V
- Efficiency
- 16.01%
How Does Yingli Energy (China) YL260P-29b Compare Against Peer CEC Listings?
Solar engineering breakdown for Yingli Energy (China) YL260P-29b: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Yingli Energy (China) and peers, Yingli Energy (China) YL260P-29b stands 18.8 W below the 278.8 W Multi-c-Si median and typical 90.4% PTC-to-STC thermal output (235.0 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Mid-range 44.6 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Yingli Energy (China) YL260P-29b Fall Across Listed CEC Models?
Distribution marker showing Yingli Energy (China) YL260P-29b (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Yingli Energy (China) YL260P-29b?
Dataset percentiles tracking Yingli Energy (China) YL260P-29b power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Yingli Energy (China) YL260P-29b?
Benchmark highlights for Yingli Energy (China) YL260P-29b covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.01% Aperture Efficiency
Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.6 V at -10 C (595.2 V string) and 51.02 V at -20 C (11 max).
31 Panels = 8,060 W STC
Occupies 50.3 m2 (542 sq ft) producing 7,285 W PTC; NEC 690.8 OCPD floor is 12.54 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.6 * (1 + (-0.32/100) * (-10 - 25)) = 49.6 V | OCPD = 1.56 * 8.04 = 12.54 A
Inputs from CEC Modules.csv for Yingli Energy (China) YL260P-29b: Voc=44.6 V, beta_Voc=-0.32%/C, Isc=8.04 A, STC=260.0 W, Area=1.624 m2.
Result: 12 panels max on 600 V (595.2 V); 31 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for Yingli Energy (China) YL260P-29b?
Official CEC datasheet figures for Yingli Energy (China) YL260P-29b (Multi-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 235.0 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.04 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.0 V / 7.43 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.01% (1.624 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Yingli Energy (China) YL260P-29b Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Yingli Energy (China) YL260P-29b modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 682 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Yingli Energy (China) Series?
Consolidated Yingli Energy (China) wattage variants sharing the Yingli Energy (China) YL260P-29b mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Yingli Energy (China) YL250P-29b | 250.0 W | 226.2 W | 38.4 V | 30.4 V | 15.3% |
| Yingli Energy (China) YL255P-29b | 255.0 W | 230.9 W | 38.7 V | 30.6 V | 15.61% |
| Yingli Energy (China) YL260P-29b | 260.0 W | 235.0 W | 44.6 V | 35.0 V | 16.01% |
| Yingli Energy (China) YL265P-29b | 265.0 W | 239.7 W | 44.6 V | 35.3 V | 16.32% |
How Many Yingli Energy (China) YL260P-29b Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Yingli Energy (China) YL260P-29b (49.6 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.02 V | 11 panels | 561.2 V | 19 panels |
| -10 C (14 F) | 49.6 V | 12 panels | 595.2 V | 20 panels |
| 0 C (32 F) | 48.17 V | 12 panels | 578.0 V | 20 panels |
| 25 C (77 F STC) | 44.6 V | 13 panels | 579.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Yingli Energy (China) YL260P-29b?
Competing CEC solar panels closest to Yingli Energy (China) YL260P-29b in nameplate wattage and Voc, starting with Gintung Energy ASEC-260G6M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-260G6M Gintung Energy |
260.0 W | Tie (0 W) | 43.84 V | 13.29% | 89.3% |
| Gintung Energy ASEC-265G6S Gintung Energy |
265.0 W | +5.0 W | 44.12 V | 13.55% | 89.5% |
| CSI Solar Co Ltd CS6X-265P CSI Solar Co Ltd |
265.0 W | +5.0 W | 43.9 V | 14.31% | 88.8% |
| Advance Power API-M270 Advance Power |
270.0 W | +10.0 W | 44.64 V | 13.84% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Yingli Energy (China) YL260P-29b?
Evaluate Yingli Energy (China) YL260P-29b (260.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Yingli Energy (China) YL260P-29b reaches 51.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of Yingli Energy (China) YL260P-29b carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Yingli Energy (China) YL260P-29b 8 kW Residential Fit
Needs 31 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-260G6M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Yingli Energy (China) YL260P-29b by Yingli Energy (China) grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Yingli Energy (China) YL260P-29b?
Multiplying Yingli Energy (China) YL260P-29b's 8.04 A short-circuit current by 1.56 equals 12.54 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Yingli Energy (China) YL260P-29b pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.6 V cold Voc at 14 F and handles 8.04 A Isc; string inverters cap Yingli Energy (China) YL260P-29b at 12 panels on 600 V.
Is Yingli Energy (China) YL260P-29b eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Yingli Energy (China) YL260P-29b rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)