WINAICO WST-270P6 is a 270.0 W STC (243.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.23% efficiency, 38.32 V Voc at 25 C, and 43.19 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 243.7 W
- Voc @ 25C
- 38.32 V
- Efficiency
- 16.23%
How Does WINAICO WST-270P6 Compare Against Peer CEC Listings?
How WINAICO WINAICO WST-270P6 handles rooftop heat (243.7 W PTC), 8 kW sizing, and cold winter string voltage.
WINAICO builds the WINAICO WST-270P6 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). Compared against AXITEC AC-270P/60S (270.0 W), this model holds typical 90.3% PTC-to-STC thermal output (243.7 W real-world rating). Lower 38.32 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.52 A overcurrent floor served by a 15 A breaker.
Where Does WINAICO WST-270P6 Fall Across Listed CEC Models?
Where WINAICO WST-270P6 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define WINAICO WST-270P6?
Percentile placement of WINAICO WST-270P6 across power density (162.4 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for WINAICO WST-270P6?
Four critical engineering numbers homeowners and solar installers check first when reviewing WINAICO WST-270P6 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.23% Aperture Efficiency
Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.19 V at -10 C (561.5 V string) and 44.58 V at -20 C (13 max).
30 Panels = 8,100 W STC
Occupies 49.9 m2 (537 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.32 * (1 + (-0.363/100) * (-10 - 25)) = 43.19 V | OCPD = 1.56 * 9.31 = 14.52 A
Inputs from CEC Modules.csv for WINAICO WST-270P6: Voc=38.32 V, beta_Voc=-0.363%/C, Isc=9.31 A, STC=270.0 W, Area=1.663 m2.
Result: 13 panels max on 600 V (561.5 V); 30 panels for 8 kW (537 sq ft).
What Are the Published CEC Specifications for WINAICO WST-270P6?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WINAICO WST-270P6. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 243.7 W (90.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.32 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.27 V / 8.65 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.363 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.23% (1.663 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many WINAICO WST-270P6 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WINAICO WST-270P6 (270.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 412 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 537 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 680 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This WINAICO Series?
All closely matched WINAICO wattages and cosmetic trims sharing the WINAICO WST-270P6 architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WINAICO WST-265P6 | 265.0 W | 239.0 W | 38.1 V | 31.26 V | 15.93% |
| WINAICO WST-270P6 | 270.0 W | 243.7 W | 38.32 V | 31.27 V | 16.23% |
How Many WINAICO WST-270P6 Modules Fit in a Cold-Weather String?
Maximum series module counts for WINAICO WST-270P6 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.58 V | 13 panels | 579.5 V | 22 panels |
| -10 C (14 F) | 43.19 V | 13 panels | 561.5 V | 23 panels |
| 0 C (32 F) | 41.8 V | 14 panels | 585.2 V | 23 panels |
| 25 C (77 F STC) | 38.32 V | 15 panels | 574.8 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to WINAICO WST-270P6?
Alternative CEC solar modules from competing brands near WINAICO WST-270P6 (270.0 W), including AXITEC AC-270P/60S. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-270P/60S AXITEC |
270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| AXITEC AC-270P/60V AXITEC |
270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-P6/60270 GCL System Integration Technology Co Ltd |
270.0 W | Tie (0 W) | 38.3 V | 16.6% | 90.6% |
| Bluesun Solar Energy Tech CoLtd BSM270M-60 Bluesun Solar Energy Tech CoLtd |
270.0 W | Tie (0 W) | 38.46 V | 16.6% | 89.9% |
What Are the Design Limits and Best-Fit Uses for WINAICO WST-270P6?
Evaluate WINAICO WST-270P6 (270.0 W STC, 38.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WINAICO WST-270P6 reaches 44.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (537 sq ft).
- 2026 tax credit baseline: cash residential installs of WINAICO WST-270P6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WINAICO WST-270P6 8 kW Residential Fit
Needs 30 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-270P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WINAICO WST-270P6 by WINAICO grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What fuse or breaker size does NEC 690.8 require for WINAICO WST-270P6?
Multiplying WINAICO WST-270P6's 9.31 A short-circuit current by 1.56 equals 14.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for WINAICO WST-270P6 before finalizing component orders.
Can WINAICO WST-270P6 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.19 V cold Voc at 14 F and handles 9.31 A Isc; string inverters cap WINAICO WST-270P6 at 13 panels on 600 V.
Is WINAICO WST-270P6 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WINAICO WST-270P6 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)