Manufacturer: WINAICO Registry: CEC Verified Engineering Specification

WINAICO WST-270P6 is a 270.0 W STC (243.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.23% efficiency, 38.32 V Voc at 25 C, and 43.19 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
243.7 W
Voc @ 25C
38.32 V
Efficiency
16.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WINAICO WST-270P6 Compare Against Peer CEC Listings?

How WINAICO WINAICO WST-270P6 handles rooftop heat (243.7 W PTC), 8 kW sizing, and cold winter string voltage.

WINAICO builds the WINAICO WST-270P6 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). Compared against AXITEC AC-270P/60S (270.0 W), this model holds typical 90.3% PTC-to-STC thermal output (243.7 W real-world rating). Lower 38.32 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.52 A overcurrent floor served by a 15 A breaker.

Where Does WINAICO WST-270P6 Fall Across Listed CEC Models?

Where WINAICO WST-270P6 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WINAICO WST-270P6 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWINAICO WST-270P6: 270.0 W

What Dataset Percentiles Define WINAICO WST-270P6?

Percentile placement of WINAICO WST-270P6 across power density (162.4 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

WINAICO WST-270P6 Engineering BenchmarksPercentile comparison of WINAICO WST-270P6 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention90.3%Module Efficiency16.23%

What Do the Dataset Ranks Show for WINAICO WST-270P6?

Four critical engineering numbers homeowners and solar installers check first when reviewing WINAICO WST-270P6 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,776

16.23% Aperture Efficiency

Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.19 V at -10 C (561.5 V string) and 44.58 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 49.9 m2 (537 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.32 * (1 + (-0.363/100) * (-10 - 25)) = 43.19 V | OCPD = 1.56 * 9.31 = 14.52 A

Inputs from CEC Modules.csv for WINAICO WST-270P6: Voc=38.32 V, beta_Voc=-0.363%/C, Isc=9.31 A, STC=270.0 W, Area=1.663 m2.

Result: 13 panels max on 600 V (561.5 V); 30 panels for 8 kW (537 sq ft).

What Are the Published CEC Specifications for WINAICO WST-270P6?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WINAICO WST-270P6. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for WINAICO WST-270P6.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 243.7 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.27 V / 8.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.363 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.23% (1.663 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many WINAICO WST-270P6 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WINAICO WST-270P6 (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 412 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 537 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 680 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This WINAICO Series?

All closely matched WINAICO wattages and cosmetic trims sharing the WINAICO WST-270P6 architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the WINAICO WST-270P6 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WINAICO WST-265P6 265.0 W 239.0 W 38.1 V 31.26 V 15.93%
WINAICO WST-270P6 270.0 W 243.7 W 38.32 V 31.27 V 16.23%

How Many WINAICO WST-270P6 Modules Fit in a Cold-Weather String?

Maximum series module counts for WINAICO WST-270P6 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.32V and beta_Voc=-0.363%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.58 V 13 panels 579.5 V 22 panels
-10 C (14 F) 43.19 V 13 panels 561.5 V 23 panels
0 C (32 F) 41.8 V 14 panels 585.2 V 23 panels
25 C (77 F STC) 38.32 V 15 panels 574.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to WINAICO WST-270P6?

Alternative CEC solar modules from competing brands near WINAICO WST-270P6 (270.0 W), including AXITEC AC-270P/60S. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-270P/60S
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
AXITEC AC-270P/60V
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WINAICO WST-270P6?

Evaluate WINAICO WST-270P6 (270.0 W STC, 38.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WINAICO WST-270P6 reaches 44.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (537 sq ft).
  • 2026 tax credit baseline: cash residential installs of WINAICO WST-270P6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WINAICO WST-270P6 8 kW Residential Fit

Needs 30 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-270P/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WINAICO WST-270P6 by WINAICO grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

What fuse or breaker size does NEC 690.8 require for WINAICO WST-270P6?

Multiplying WINAICO WST-270P6's 9.31 A short-circuit current by 1.56 equals 14.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for WINAICO WST-270P6 before finalizing component orders.

Can WINAICO WST-270P6 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.19 V cold Voc at 14 F and handles 9.31 A Isc; string inverters cap WINAICO WST-270P6 at 13 panels on 600 V.

Is WINAICO WST-270P6 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WINAICO WST-270P6 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.