Skip to main content
WireAndSun
Calculators
CEC PV Module

WINAICO WSP-270P6 — CEC Solar Module Specifications

Manufacturer: WINAICO Registry: CEC Verified Engineering Specification

WINAICO WSP-270P6 is a 270.0 W STC (243.7 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.23% efficiency, 38.32 V Voc at 25 C, and 43.19 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
270.0 W
PTC Wattage
243.7 W
Voc @ 25C
38.32 V
Efficiency
16.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WINAICO WSP-270P6 Compare Against Peer CEC Listings?

How WINAICO WINAICO WSP-270P6 handles rooftop heat (243.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, WINAICO WSP-270P6 exhibits 9.31 A short-circuit current, requiring a 14.52 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #18,572 of 21,677 (8.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 49.9 m2 for an 8 kW system (38 panels for 10 kW). Lower 38.32 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does WINAICO WSP-270P6 Fall Across Listed CEC Models?

Where WINAICO WSP-270P6 (270.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WINAICO WSP-270P6 (270.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWINAICO WSP-270P6: 270.0 W

What Dataset Percentiles Define WINAICO WSP-270P6?

Percentile placement of WINAICO WSP-270P6 across power density (162.4 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

WINAICO WSP-270P6 Engineering BenchmarksPercentile comparison of WINAICO WSP-270P6 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage270.0 WPTC/STC Retention90.3%Module Efficiency16.23%

What Do the Dataset Ranks Show for WINAICO WSP-270P6?

Four critical engineering numbers homeowners and solar installers check first when reviewing WINAICO WSP-270P6 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #18,572 / 21,677

270.0 W STC · Higher Than 12.9%

270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,776

16.23% Aperture Efficiency

Power density 162.4 W/m2 (3.68 percentage points below 19.91% CEC median). PTC/STC ratio: 90.3% (rank #18,305).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.19 V at -10 C (561.5 V string) and 44.58 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,100 W STC

Occupies 49.9 m2 (537 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.32 * (1 + (-0.363/100) * (-10 - 25)) = 43.19 V | OCPD = 1.56 * 9.31 = 14.52 A

Inputs from CEC Modules.csv for WINAICO WSP-270P6: Voc=38.32 V, beta_Voc=-0.363%/C, Isc=9.31 A, STC=270.0 W, Area=1.663 m2.

Result: 13 panels max on 600 V (561.5 V); 30 panels for 8 kW (537 sq ft).

What Are the Published CEC Specifications for WINAICO WSP-270P6?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for WINAICO WSP-270P6. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for WINAICO WSP-270P6.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 270.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 243.7 W (90.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.32 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.27 V / 8.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.363 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.23% (1.663 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many WINAICO WSP-270P6 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using WINAICO WSP-270P6 (270.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 23 6.21 kW 412 sq ft $1,554 $2,628
8 kW Class 30 8.1 kW 537 sq ft $2,027 $3,428
10 kW Class 38 10.26 kW 680 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This WINAICO Series?

All closely matched WINAICO wattages and cosmetic trims sharing the WINAICO WSP-270P6 architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the WINAICO WSP-270P6 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WINAICO WSP-265P6 265.0 W 239.0 W 38.1 V 31.26 V 15.93%
WINAICO WSP-270P6 270.0 W 243.7 W 38.32 V 31.27 V 16.23%

How Many WINAICO WSP-270P6 Modules Fit in a Cold-Weather String?

Maximum series module counts for WINAICO WSP-270P6 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.32V and beta_Voc=-0.363%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.58 V 13 panels 579.5 V 22 panels
-10 C (14 F) 43.19 V 13 panels 561.5 V 23 panels
0 C (32 F) 41.8 V 14 panels 585.2 V 23 panels
25 C (77 F STC) 38.32 V 15 panels 574.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to WINAICO WSP-270P6?

Alternative CEC solar modules from competing brands near WINAICO WSP-270P6 (270.0 W), including AXITEC AC-270P/60S. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-270P/60S
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
AXITEC AC-270P/60V
AXITEC
270.0 W Tie (0 W) 38.31 V 16.56% 92.2%
GCL System Integration Technology Co Ltd GCL-P6/60270
GCL System Integration Technology Co Ltd
270.0 W Tie (0 W) 38.3 V 16.6% 90.6%
Bluesun Solar Energy Tech CoLtd BSM270M-60
Bluesun Solar Energy Tech CoLtd
270.0 W Tie (0 W) 38.46 V 16.6% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WINAICO WSP-270P6?

Evaluate WINAICO WSP-270P6 (270.0 W STC, 38.32 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WINAICO WSP-270P6 reaches 44.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 537 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (537 sq ft).
  • 2026 tax credit baseline: cash residential installs of WINAICO WSP-270P6 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WINAICO WSP-270P6 8 kW Residential Fit

Needs 30 modules (537 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-270P/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 243.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WINAICO WSP-270P6 by WINAICO grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Why is WINAICO WSP-270P6 PTC wattage (243.7 W) lower than STC (270.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 243.7 W PTC (90.3% retention) across WINAICO WSP-270P6's 1.663 m2 aperture.

Who should skip WINAICO WSP-270P6 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 WINAICO WSP-270P6 panels (537 sq ft) leave unusable roof gaps vs. AXITEC AC-270P/60S.

What is the 1,000 V commercial string limit for WINAICO WSP-270P6?

On 1,000 V commercial inverters at -10 C (43.19 V cold Voc), WINAICO WSP-270P6 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting WINAICO WSP-270P6.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.