Vikram Solar SOMERA VSMH7847505 is a 475.0 W STC (438.1 W PTC) Mono-c-Si solar module ranking #4,892 of 21,677 CEC listings (top 22.9%; higher than 77.1% of peers). It delivers 19.96% efficiency, 52.8 V Voc at 25 C, and 58.16 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 475.0 W
- PTC Wattage
- 438.1 W
- Voc @ 25C
- 52.8 V
- Efficiency
- 19.96%
How Does Vikram Solar SOMERA VSMH7847505 Compare Against Peer CEC Listings?
Solar engineering breakdown for Vikram Solar SOMERA VSMH7847505: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 475.0 W STC and 438.1 W PTC, Vikram Solar SOMERA VSMH7847505 sits +90.0 W vs all-CEC median (top 22.9%; higher than 77.1% of peers) among 21,677 listed modules. Power density reaches 199.6 W/m2 (0.05 percentage points above 19.91% CEC median). Higher 52.8 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 17 panels in series. Alternative peer CSI Solar Co Ltd CS3Y-480P rates 480.0 W.
Where Does Vikram Solar SOMERA VSMH7847505 Fall Across Listed CEC Models?
Distribution marker showing Vikram Solar SOMERA VSMH7847505 (475.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Vikram Solar SOMERA VSMH7847505?
Dataset percentiles tracking Vikram Solar SOMERA VSMH7847505 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMH7847505?
Benchmark highlights for Vikram Solar SOMERA VSMH7847505 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 22.9% STC Output
475.0 W STC (+90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.96% Aperture Efficiency
Power density 199.6 W/m2 (0.05 percentage points above 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.16 V at -10 C (581.6 V string) and 59.69 V at -20 C (10 max).
17 Panels = 8,075 W STC
Occupies 40.5 m2 (436 sq ft) producing 7,448 W PTC; NEC 690.8 OCPD floor is 17.86 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.8 * (1 + (-0.29/100) * (-10 - 25)) = 58.16 V | OCPD = 1.56 * 11.45 = 17.86 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMH7847505: Voc=52.8 V, beta_Voc=-0.29%/C, Isc=11.45 A, STC=475.0 W, Area=2.38 m2.
Result: 10 panels max on 600 V (581.6 V); 17 panels for 8 kW (436 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSMH7847505?
Official CEC datasheet figures for Vikram Solar SOMERA VSMH7847505 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 475.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 438.1 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.45 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.9 V / 10.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.29 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.96% (2.38 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Vikram Solar SOMERA VSMH7847505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Vikram Solar SOMERA VSMH7847505 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.17 kW | 333 sq ft | $1,544 | $2,611 |
| 8 kW Class | 17 | 8.07 kW | 436 sq ft | $2,020 | $3,415 |
| 10 kW Class | 22 | 10.45 kW | 564 sq ft | $2,616 | $4,423 |
How Many Vikram Solar SOMERA VSMH7847505 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Vikram Solar SOMERA VSMH7847505 (58.16 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 59.69 V | 10 panels | 596.9 V | 16 panels |
| -10 C (14 F) | 58.16 V | 10 panels | 581.6 V | 17 panels |
| 0 C (32 F) | 56.63 V | 10 panels | 566.3 V | 17 panels |
| 25 C (77 F STC) | 52.8 V | 11 panels | 580.8 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMH7847505?
Competing CEC solar panels closest to Vikram Solar SOMERA VSMH7847505 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3Y-480P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | +5.0 W | 52.8 V | 20.96% | 93.2% |
| CSI Solar Co Ltd CS3Y-470MS CSI Solar Co Ltd |
470.0 W | -5.0 W | 52.5 V | 20.52% | 93.5% |
| CSI Solar Co Ltd CS3Y-485MS CSI Solar Co Ltd |
485.0 W | +10.0 W | 53.1 V | 21.18% | 93.6% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | -15.0 W | 52.0 V | 20.09% | 93.1% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMH7847505?
Evaluate Vikram Solar SOMERA VSMH7847505 (475.0 W STC, 52.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMH7847505 reaches 59.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 436 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (436 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMH7847505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSMH7847505 8 kW Residential Fit
Needs 17 modules (436 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-480P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 438.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSMH7847505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar SOMERA VSMH7847505 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar SOMERA VSMH7847505 cold Voc rises from 52.8 V to 58.16 V (beta_Voc -0.29%/C), capping a 600 V string at 10 panels (581.6 V).
How much roof area does an 8 kW array of Vikram Solar SOMERA VSMH7847505 need?
An 8 kW DC system uses 17 Vikram Solar SOMERA VSMH7847505 modules (8,075 W STC / 7,448 W PTC), covering roughly 436 sq ft and saving ~$2,020/yr at 18.54 c/kWh.
How does Vikram Solar SOMERA VSMH7847505 compare against CSI Solar Co Ltd CS3Y-480P?
Vikram Solar SOMERA VSMH7847505 outputs 475.0 W STC (52.8 V Voc, rank #4,892 of 21,677), while CSI Solar Co Ltd CS3Y-480P delivers 480.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)