Skip to main content
WireAndSun
Calculators
CEC PV Module

Vikram Solar SOMERA VSMDT7238005 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMDT7238005 is a 380.0 W STC (350.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 18.81% efficiency, 47.1 V Voc at 25 C, and 51.57 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
350.6 W
Voc @ 25C
47.1 V
Efficiency
18.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMDT7238005 Compare Against Peer CEC Listings?

Engineering position of Vikram Solar SOMERA VSMDT7238005 (380.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.

Ranking #11,043 across 21,677 CEC solar panels (below all-CEC median; higher than 47.6% of peers), Vikram Solar SOMERA VSMDT7238005 operates as a compact residential or specialty off-grid module sitting 30.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.1 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), 22 panels occupy 478 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Vikram Solar SOMERA VSMDT7238005 Fall Across Listed CEC Models?

Plots Vikram Solar SOMERA VSMDT7238005 at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMDT7238005 (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 380.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMDT7238005?

Benchmarks Vikram Solar SOMERA VSMDT7238005 on STC wattage, thermal PTC/STC retention, and 18.81 aperture conversion efficiency against CEC peers.

Vikram Solar SOMERA VSMDT7238005 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMDT7238005 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention92.3%Module Efficiency18.81%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDT7238005?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMDT7238005 by Vikram Solar.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,807

18.81% Aperture Efficiency

Power density 188.1 W/m2 (1.10 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.57 V at -10 C (567.3 V string) and 52.84 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 44.4 m2 (478 sq ft) producing 7,713 W PTC; NEC 690.8 OCPD floor is 15.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.1 * (1 + (-0.271/100) * (-10 - 25)) = 51.57 V | OCPD = 1.56 * 10.09 = 15.74 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDT7238005: Voc=47.1 V, beta_Voc=-0.271%/C, Isc=10.09 A, STC=380.0 W, Area=2.02 m2.

Result: 11 panels max on 600 V (567.3 V); 22 panels for 8 kW (478 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDT7238005?

Laboratory test ratings recorded for Vikram Solar SOMERA VSMDT7238005 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMDT7238005.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 350.6 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.2 V / 9.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.81% (2.02 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Vikram Solar SOMERA VSMDT7238005 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (478 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMDT7238005.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 348 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 478 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 587 sq ft $2,568 $4,342

How Many Vikram Solar SOMERA VSMDT7238005 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Vikram Solar SOMERA VSMDT7238005 (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.1V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.84 V 11 panels 581.2 V 18 panels
-10 C (14 F) 51.57 V 11 panels 567.3 V 19 panels
0 C (32 F) 50.29 V 11 panels 553.2 V 19 panels
25 C (77 F STC) 47.1 V 12 panels 565.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDT7238005?

Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMDT7238005 matched near 380.0 W STC and 47.1 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W Tie (0 W) 47.8 V 19.29% 93.5%
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-385MB-AG
CSI Solar Co Ltd
385.0 W +5.0 W 48.0 V 19.85% 93.9%
Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF
Boviet Solar Technology Co Ltd
385.0 W +5.0 W 48.45 V 19.15% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDT7238005?

Evaluate Vikram Solar SOMERA VSMDT7238005 (380.0 W STC, 47.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDT7238005 reaches 52.84 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (478 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDT7238005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMDT7238005 8 kW Residential Fit

Needs 22 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 350.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMDT7238005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Vikram Solar SOMERA VSMDT7238005 panels fit on a 600 V winter solar string?

At -10 C (14 F), Vikram Solar SOMERA VSMDT7238005 cold Voc rises from 47.1 V to 51.57 V (beta_Voc -0.271%/C), capping a 600 V string at 11 panels (567.3 V).

How much roof area does an 8 kW array of Vikram Solar SOMERA VSMDT7238005 need?

An 8 kW DC system uses 22 Vikram Solar SOMERA VSMDT7238005 modules (8,360 W STC / 7,713 W PTC), covering roughly 478 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does Vikram Solar SOMERA VSMDT7238005 compare against CSI Solar Co Ltd CS3U-380PB-AG?

Vikram Solar SOMERA VSMDT7238005 outputs 380.0 W STC (47.1 V Voc, rank #11,043 of 21,677), while CSI Solar Co Ltd CS3U-380PB-AG delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.