Vikram Solar SOMERA VSMDT7237505 is a 375.0 W STC (345.9 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 18.56% efficiency, 47.0 V Voc at 25 C, and 51.46 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 345.9 W
- Voc @ 25C
- 47.0 V
- Efficiency
- 18.56%
How Does Vikram Solar SOMERA VSMDT7237505 Compare Against Peer CEC Listings?
Engineering position of Vikram Solar SOMERA VSMDT7237505 (375.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Vikram Solar SOMERA VSMDT7237505 pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 47.0 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,610 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS3U-380PB-AG offers a 380.0 W alternative.
Where Does Vikram Solar SOMERA VSMDT7237505 Fall Across Listed CEC Models?
Plots Vikram Solar SOMERA VSMDT7237505 at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Vikram Solar SOMERA VSMDT7237505?
Benchmarks Vikram Solar SOMERA VSMDT7237505 on STC wattage, thermal PTC/STC retention, and 18.56 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDT7237505?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.56% Aperture Efficiency
Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.46 V at -10 C (566.1 V string) and 52.73 V at -20 C (11 max).
22 Panels = 8,250 W STC
Occupies 44.4 m2 (478 sq ft) producing 7,610 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.0 * (1 + (-0.271/100) * (-10 - 25)) = 51.46 V | OCPD = 1.56 * 9.99 = 15.58 A
Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDT7237505: Voc=47.0 V, beta_Voc=-0.271%/C, Isc=9.99 A, STC=375.0 W, Area=2.02 m2.
Result: 11 panels max on 600 V (566.1 V); 22 panels for 8 kW (478 sq ft).
What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDT7237505?
Laboratory test ratings recorded for Vikram Solar SOMERA VSMDT7237505 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 345.9 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.1 V / 9.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.56% (2.02 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Vikram Solar SOMERA VSMDT7237505 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (478 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMDT7237505.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 348 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 478 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 587 sq ft | $2,533 | $4,283 |
How Many Vikram Solar SOMERA VSMDT7237505 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Vikram Solar SOMERA VSMDT7237505 (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.73 V | 11 panels | 580.0 V | 18 panels |
| -10 C (14 F) | 51.46 V | 11 panels | 566.1 V | 19 panels |
| 0 C (32 F) | 50.18 V | 11 panels | 552.0 V | 19 panels |
| 25 C (77 F STC) | 47.0 V | 12 panels | 564.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDT7237505?
Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMDT7237505 matched near 375.0 W STC and 47.0 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-380PB-AG CSI Solar Co Ltd |
380.0 W | +5.0 W | 47.8 V | 19.29% | 93.5% |
| Auxin Solar AXN6M612B380 Auxin Solar |
380.0 W | +5.0 W | 47.94 V | 19.3% | 93.1% |
| CSI Solar Co Ltd CS3U-385MB-AG CSI Solar Co Ltd |
385.0 W | +10.0 W | 48.0 V | 19.85% | 93.9% |
| CSI Solar Co Ltd CS3U-360MB-AG CSI Solar Co Ltd |
360.0 W | -15.0 W | 47.0 V | 18.56% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDT7237505?
Evaluate Vikram Solar SOMERA VSMDT7237505 (375.0 W STC, 47.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDT7237505 reaches 52.73 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (478 sq ft).
- 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDT7237505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar SOMERA VSMDT7237505 8 kW Residential Fit
Needs 22 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 345.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMDT7237505?
Multiplying Vikram Solar SOMERA VSMDT7237505's 9.99 A short-circuit current by 1.56 equals 15.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Vikram Solar SOMERA VSMDT7237505 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.46 V cold Voc at 14 F and handles 9.99 A Isc; string inverters cap Vikram Solar SOMERA VSMDT7237505 at 11 panels on 600 V.
Is Vikram Solar SOMERA VSMDT7237505 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMDT7237505 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)