Skip to main content
WireAndSun
Calculators
CEC PV Module

Vikram Solar SOMERA VSMDT7237505 — CEC Solar Module Specifications

Manufacturer: Vikram Solar Registry: CEC Verified Engineering Specification

Vikram Solar SOMERA VSMDT7237505 is a 375.0 W STC (345.9 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 18.56% efficiency, 47.0 V Voc at 25 C, and 51.46 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
345.9 W
Voc @ 25C
47.0 V
Efficiency
18.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Vikram Solar SOMERA VSMDT7237505 Compare Against Peer CEC Listings?

Engineering position of Vikram Solar SOMERA VSMDT7237505 (375.0 W STC) vs. CSI Solar Co Ltd CS3U-380PB-AG across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Vikram Solar SOMERA VSMDT7237505 pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 47.0 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,610 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer CSI Solar Co Ltd CS3U-380PB-AG offers a 380.0 W alternative.

Where Does Vikram Solar SOMERA VSMDT7237505 Fall Across Listed CEC Models?

Plots Vikram Solar SOMERA VSMDT7237505 at 375.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Vikram Solar SOMERA VSMDT7237505 (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCVikram Solar SOMER: 375.0 W

What Dataset Percentiles Define Vikram Solar SOMERA VSMDT7237505?

Benchmarks Vikram Solar SOMERA VSMDT7237505 on STC wattage, thermal PTC/STC retention, and 18.56 aperture conversion efficiency against CEC peers.

Vikram Solar SOMERA VSMDT7237505 Engineering BenchmarksPercentile comparison of Vikram Solar SOMERA VSMDT7237505 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention92.2%Module Efficiency18.56%

What Do the Dataset Ranks Show for Vikram Solar SOMERA VSMDT7237505?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,241

18.56% Aperture Efficiency

Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.46 V at -10 C (566.1 V string) and 52.73 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 44.4 m2 (478 sq ft) producing 7,610 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.0 * (1 + (-0.271/100) * (-10 - 25)) = 51.46 V | OCPD = 1.56 * 9.99 = 15.58 A

Inputs from CEC Modules.csv for Vikram Solar SOMERA VSMDT7237505: Voc=47.0 V, beta_Voc=-0.271%/C, Isc=9.99 A, STC=375.0 W, Area=2.02 m2.

Result: 11 panels max on 600 V (566.1 V); 22 panels for 8 kW (478 sq ft).

What Are the Published CEC Specifications for Vikram Solar SOMERA VSMDT7237505?

Laboratory test ratings recorded for Vikram Solar SOMERA VSMDT7237505 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Vikram Solar SOMERA VSMDT7237505.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 345.9 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.1 V / 9.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.56% (2.02 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Vikram Solar SOMERA VSMDT7237505 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (478 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar SOMERA VSMDT7237505.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 348 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 478 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 587 sq ft $2,533 $4,283

How Many Vikram Solar SOMERA VSMDT7237505 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Vikram Solar SOMERA VSMDT7237505 (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.0V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.73 V 11 panels 580.0 V 18 panels
-10 C (14 F) 51.46 V 11 panels 566.1 V 19 panels
0 C (32 F) 50.18 V 11 panels 552.0 V 19 panels
25 C (77 F STC) 47.0 V 12 panels 564.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Vikram Solar SOMERA VSMDT7237505?

Closest cross-brand CEC competitors to Vikram Solar SOMERA VSMDT7237505 matched near 375.0 W STC and 47.0 V Voc, led by CSI Solar Co Ltd CS3U-380PB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-380PB-AG
CSI Solar Co Ltd
380.0 W +5.0 W 47.8 V 19.29% 93.5%
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W +5.0 W 47.94 V 19.3% 93.1%
CSI Solar Co Ltd CS3U-385MB-AG
CSI Solar Co Ltd
385.0 W +10.0 W 48.0 V 19.85% 93.9%
CSI Solar Co Ltd CS3U-360MB-AG
CSI Solar Co Ltd
360.0 W -15.0 W 47.0 V 18.56% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Vikram Solar SOMERA VSMDT7237505?

Evaluate Vikram Solar SOMERA VSMDT7237505 (375.0 W STC, 47.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar SOMERA VSMDT7237505 reaches 52.73 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 478 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (478 sq ft).
  • 2026 tax credit baseline: cash residential installs of Vikram Solar SOMERA VSMDT7237505 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Vikram Solar SOMERA VSMDT7237505 8 kW Residential Fit

Needs 22 modules (478 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3U-380PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 345.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Vikram Solar SOMERA VSMDT7237505 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Vikram Solar SOMERA VSMDT7237505?

Multiplying Vikram Solar SOMERA VSMDT7237505's 9.99 A short-circuit current by 1.56 equals 15.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Vikram Solar SOMERA VSMDT7237505 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.46 V cold Voc at 14 F and handles 9.99 A Isc; string inverters cap Vikram Solar SOMERA VSMDT7237505 at 11 panels on 600 V.

Is Vikram Solar SOMERA VSMDT7237505 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Vikram Solar SOMERA VSMDT7237505 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.