Vikram Solar PREXOS VSMDHT7245005 is a 450.0 W STC (414.4 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 20.36% efficiency, 49.0 V Voc at 25 C, and 54.09 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 414.4 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 20.36%
How Does Vikram Solar PREXOS VSMDHT7245005 Compare Against Peer CEC Listings?
Engineering position of Vikram Solar PREXOS VSMDHT7245005 (450.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,679 across 21,677 CEC solar panels (top 27.8%; higher than 72.2% of peers), Vikram Solar PREXOS VSMDHT7245005 operates as a modern high-density residential and light-commercial module sitting 40.0 W above the 410.0 W Mono-c-Si median. Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677), 18 panels occupy 428 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Vikram Solar PREXOS VSMDHT7245005 Fall Across Listed CEC Models?
Plots Vikram Solar PREXOS VSMDHT7245005 at 450.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Vikram Solar PREXOS VSMDHT7245005?
Benchmarks Vikram Solar PREXOS VSMDHT7245005 on STC wattage, thermal PTC/STC retention, and 20.36 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Vikram Solar PREXOS VSMDHT7245005?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Vikram Solar PREXOS VSMDHT7245005 by Vikram Solar.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.36% Aperture Efficiency
Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.09 V at -10 C (595.0 V string) and 55.55 V at -20 C (10 max).
18 Panels = 8,100 W STC
Occupies 39.8 m2 (428 sq ft) producing 7,459 W PTC; NEC 690.8 OCPD floor is 18.36 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.297/100) * (-10 - 25)) = 54.09 V | OCPD = 1.56 * 11.77 = 18.36 A
Inputs from CEC Modules.csv for Vikram Solar PREXOS VSMDHT7245005: Voc=49.0 V, beta_Voc=-0.297%/C, Isc=11.77 A, STC=450.0 W, Area=2.21 m2.
Result: 11 panels max on 600 V (595.0 V); 18 panels for 8 kW (428 sq ft).
What Are the Published CEC Specifications for Vikram Solar PREXOS VSMDHT7245005?
Laboratory test ratings recorded for Vikram Solar PREXOS VSMDHT7245005 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 414.4 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.6 V / 10.82 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.297 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.36% (2.21 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Vikram Solar PREXOS VSMDHT7245005 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (428 sq ft at 8 kW), and estimated Year-1 electric bill offset for Vikram Solar PREXOS VSMDHT7245005.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 333 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 428 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 547 sq ft | $2,591 | $4,380 |
How Many Vikram Solar PREXOS VSMDHT7245005 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Vikram Solar PREXOS VSMDHT7245005 (beta_Voc -0.297%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.55 V | 10 panels | 555.5 V | 18 panels |
| -10 C (14 F) | 54.09 V | 11 panels | 595.0 V | 18 panels |
| 0 C (32 F) | 52.64 V | 11 panels | 579.0 V | 18 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Vikram Solar PREXOS VSMDHT7245005?
Closest cross-brand CEC competitors to Vikram Solar PREXOS VSMDHT7245005 matched near 450.0 W STC and 49.0 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF Boviet Solar Technology Co Ltd |
455.0 W | +5.0 W | 49.25 V | 20.4% | 93.8% |
| Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF-DG Boviet Solar Technology Co Ltd |
455.0 W | +5.0 W | 49.25 V | 20.4% | 93.8% |
| CSI Solar Co Ltd CS3W-455MB-AG CSI Solar Co Ltd |
455.0 W | +5.0 W | 49.3 V | 21.06% | 92.9% |
| Caterpillar Inc PVC455MB03H Caterpillar Inc |
455.0 W | +5.0 W | 49.8 V | 21.56% | 93.8% |
What Are the Design Limits and Best-Fit Uses for Vikram Solar PREXOS VSMDHT7245005?
Evaluate Vikram Solar PREXOS VSMDHT7245005 (450.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Vikram Solar PREXOS VSMDHT7245005 reaches 55.55 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Vikram Solar PREXOS VSMDHT7245005 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Vikram Solar PREXOS VSMDHT7245005 8 kW Residential Fit
Needs 18 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 414.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Vikram Solar PREXOS VSMDHT7245005 by Vikram Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Vikram Solar PREXOS VSMDHT7245005 panels fit on a 600 V winter solar string?
At -10 C (14 F), Vikram Solar PREXOS VSMDHT7245005 cold Voc rises from 49.0 V to 54.09 V (beta_Voc -0.297%/C), capping a 600 V string at 11 panels (595.0 V).
How much roof area does an 8 kW array of Vikram Solar PREXOS VSMDHT7245005 need?
An 8 kW DC system uses 18 Vikram Solar PREXOS VSMDHT7245005 modules (8,100 W STC / 7,459 W PTC), covering roughly 428 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Vikram Solar PREXOS VSMDHT7245005 compare against Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF?
Vikram Solar PREXOS VSMDHT7245005 outputs 450.0 W STC (49.0 V Voc, rank #5,679 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)