United Renewable Energy Co Ltd F6P270H3A is a 270.0 W STC (242.9 W PTC) Multi-c-Si solar module ranking #18,572 of 21,677 CEC listings (below all-CEC median; higher than 12.9% of peers). It delivers 16.6% efficiency, 38.2 V Voc at 25 C, and 42.34 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 270.0 W
- PTC Wattage
- 242.9 W
- Voc @ 25C
- 38.2 V
- Efficiency
- 16.6%
How Does United Renewable Energy Co Ltd F6P270H3A Compare Against Peer CEC Listings?
Engineering position of United Renewable Energy Co Ltd F6P270H3A (270.0 W STC) vs. GCL System Integration Technology Co Ltd GCL-P6/60270 across 1,407 CEC Multi-c-Si solar modules.
Ranking #18,572 across 21,677 CEC solar panels (below all-CEC median; higher than 12.9% of peers), United Renewable Energy Co Ltd F6P270H3A operates as a compact residential or specialty off-grid module sitting 8.8 W below the 278.8 W Multi-c-Si median. Lower 38.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 90.0% PTC-to-STC thermal output (242.9 W real-world rating), 30 panels occupy 525 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does United Renewable Energy Co Ltd F6P270H3A Fall Across Listed CEC Models?
Plots United Renewable Energy Co Ltd F6P270H3A at 270.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define United Renewable Energy Co Ltd F6P270H3A?
Benchmarks United Renewable Energy Co Ltd F6P270H3A on STC wattage, thermal PTC/STC retention, and 16.6 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd F6P270H3A?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for United Renewable Energy Co Ltd F6P270H3A by United Renewable Energy Co Ltd.
270.0 W STC · Higher Than 12.9%
270.0 W STC (-115.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.6% Aperture Efficiency
Power density 165.9 W/m2 (3.31 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.34 V at -10 C (592.8 V string) and 43.53 V at -20 C (13 max).
30 Panels = 8,100 W STC
Occupies 48.8 m2 (525 sq ft) producing 7,287 W PTC; NEC 690.8 OCPD floor is 13.99 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.2 * (1 + (-0.31/100) * (-10 - 25)) = 42.34 V | OCPD = 1.56 * 8.97 = 13.99 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd F6P270H3A: Voc=38.2 V, beta_Voc=-0.31%/C, Isc=8.97 A, STC=270.0 W, Area=1.627 m2.
Result: 14 panels max on 600 V (592.8 V); 30 panels for 8 kW (525 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd F6P270H3A?
Laboratory test ratings recorded for United Renewable Energy Co Ltd F6P270H3A (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 270.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 242.9 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.97 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.8 V / 8.24 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.6% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd F6P270H3A Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (525 sq ft at 8 kW), and estimated Year-1 electric bill offset for United Renewable Energy Co Ltd F6P270H3A.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 23 | 6.21 kW | 403 sq ft | $1,554 | $2,628 |
| 8 kW Class | 30 | 8.1 kW | 525 sq ft | $2,027 | $3,428 |
| 10 kW Class | 38 | 10.26 kW | 665 sq ft | $2,568 | $4,342 |
How Many United Renewable Energy Co Ltd F6P270H3A Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for United Renewable Energy Co Ltd F6P270H3A (beta_Voc -0.31%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.53 V | 13 panels | 565.9 V | 22 panels |
| -10 C (14 F) | 42.34 V | 14 panels | 592.8 V | 23 panels |
| 0 C (32 F) | 41.16 V | 14 panels | 576.2 V | 24 panels |
| 25 C (77 F STC) | 38.2 V | 15 panels | 573.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd F6P270H3A?
Closest cross-brand CEC competitors to United Renewable Energy Co Ltd F6P270H3A matched near 270.0 W STC and 38.2 V Voc, led by GCL System Integration Technology Co Ltd GCL-P6/60270.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/60270 GCL System Integration Technology Co Ltd |
270.0 W | Tie (0 W) | 38.3 V | 16.6% | 90.6% |
| AXITEC AC-270P/60S AXITEC |
270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| AXITEC AC-270P/60V AXITEC |
270.0 W | Tie (0 W) | 38.31 V | 16.56% | 92.2% |
| Bluesun Solar Energy Tech CoLtd BSM270M-60 Bluesun Solar Energy Tech CoLtd |
270.0 W | Tie (0 W) | 38.46 V | 16.6% | 89.9% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd F6P270H3A?
Evaluate United Renewable Energy Co Ltd F6P270H3A (270.0 W STC, 38.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd F6P270H3A reaches 43.53 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 525 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (525 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd F6P270H3A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd F6P270H3A 8 kW Residential Fit
Needs 30 modules (525 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60270.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 242.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd F6P270H3A by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many United Renewable Energy Co Ltd F6P270H3A panels fit on a 600 V winter solar string?
At -10 C (14 F), United Renewable Energy Co Ltd F6P270H3A cold Voc rises from 38.2 V to 42.34 V (beta_Voc -0.31%/C), capping a 600 V string at 14 panels (592.8 V).
How much roof area does an 8 kW array of United Renewable Energy Co Ltd F6P270H3A need?
An 8 kW DC system uses 30 United Renewable Energy Co Ltd F6P270H3A modules (8,100 W STC / 7,287 W PTC), covering roughly 525 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does United Renewable Energy Co Ltd F6P270H3A compare against GCL System Integration Technology Co Ltd GCL-P6/60270?
United Renewable Energy Co Ltd F6P270H3A outputs 270.0 W STC (38.2 V Voc, rank #18,572 of 21,677), while GCL System Integration Technology Co Ltd GCL-P6/60270 delivers 270.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)