Skip to main content
WireAndSun
Calculators
CEC PV Module

United Renewable Energy Co Ltd D6P235A3F — CEC Solar Module Specifications

Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd D6P235A3F is a 235.0 W STC (210.3 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.59% efficiency, 37.06 V Voc at 25 C, and 41.34 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
210.3 W
Voc @ 25C
37.06 V
Efficiency
14.59%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd D6P235A3F Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd D6P235A3F handles rooftop heat (210.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, United Renewable Energy Co Ltd D6P235A3F exhibits 8.45 A short-circuit current, requiring a 13.18 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,368 of 21,677 (43.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 56.4 m2 for an 8 kW system (43 panels for 10 kW). Lower 37.06 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does United Renewable Energy Co Ltd D6P235A3F Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd D6P235A3F (235.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd D6P235A3F (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 235.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd D6P235A3F?

Percentile placement of United Renewable Energy Co Ltd D6P235A3F across power density (145.9 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd D6P235A3F Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd D6P235A3F wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention89.5%Module Efficiency14.59%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6P235A3F?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd D6P235A3F specifications.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,296

14.59% Aperture Efficiency

Power density 145.9 W/m2 (5.32 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.34 V at -10 C (578.8 V string) and 42.56 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.4 m2 (607 sq ft) producing 7,360 W PTC; NEC 690.8 OCPD floor is 13.18 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.06 * (1 + (-0.33/100) * (-10 - 25)) = 41.34 V | OCPD = 1.56 * 8.45 = 13.18 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6P235A3F: Voc=37.06 V, beta_Voc=-0.33%/C, Isc=8.45 A, STC=235.0 W, Area=1.611 m2.

Result: 14 panels max on 600 V (578.8 V); 35 panels for 8 kW (607 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6P235A3F?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd D6P235A3F.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd D6P235A3F.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 210.3 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.06 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.34 V / 8.01 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.59% (1.611 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd D6P235A3F Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd D6P235A3F (235.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 451 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 607 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 746 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?

All closely matched United Renewable Energy Co Ltd wattages and cosmetic trims sharing the United Renewable Energy Co Ltd D6P235A3F architecture.

Sibling CEC listings grouped into the United Renewable Energy Co Ltd D6P235A3F wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
United Renewable Energy Co Ltd D6P225A3F 225.0 W 201.1 W 36.75 V 29.19 V 13.97%
United Renewable Energy Co Ltd D6P230A3F 230.0 W 205.7 W 36.87 V 29.3 V 14.28%
United Renewable Energy Co Ltd D6P235A3F 235.0 W 210.3 W 37.06 V 29.34 V 14.59%
United Renewable Energy Co Ltd D6P240A3F 240.0 W 214.9 W 37.18 V 29.42 V 14.9%
United Renewable Energy Co Ltd D6P245A3F 245.0 W 219.5 W 37.31 V 29.56 V 15.21%

How Many United Renewable Energy Co Ltd D6P235A3F Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd D6P235A3F from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.06V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.56 V 14 panels 595.8 V 23 panels
-10 C (14 F) 41.34 V 14 panels 578.8 V 24 panels
0 C (32 F) 40.12 V 14 panels 561.7 V 24 panels
25 C (77 F STC) 37.06 V 16 panels 593.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6P235A3F?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd D6P235A3F (235.0 W), including Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Centrosolar America DP60 235
Centrosolar America
235.0 W Tie (0 W) 36.98 V 14.33% 90.0%
AXITEC AC-235P/156-60S
AXITEC
235.0 W Tie (0 W) 37.16 V 14.48% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6P235A3F?

Evaluate United Renewable Energy Co Ltd D6P235A3F (235.0 W STC, 37.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6P235A3F reaches 42.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 607 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (607 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6P235A3F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd D6P235A3F 8 kW Residential Fit

Needs 35 modules (607 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 210.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd D6P235A3F by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is United Renewable Energy Co Ltd D6P235A3F PTC wattage (210.3 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 210.3 W PTC (89.5% retention) across United Renewable Energy Co Ltd D6P235A3F's 1.611 m2 aperture.

Who should skip United Renewable Energy Co Ltd D6P235A3F on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 United Renewable Energy Co Ltd D6P235A3F panels (607 sq ft) leave unusable roof gaps vs. Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q.

What is the 1,000 V commercial string limit for United Renewable Energy Co Ltd D6P235A3F?

On 1,000 V commercial inverters at -10 C (41.34 V cold Voc), United Renewable Energy Co Ltd D6P235A3F fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.