United Renewable Energy Co Ltd D6M380H4A is a 380.0 W STC (349.0 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.79% efficiency, 48.06 V Voc at 25 C, and 53.39 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 349.0 W
- Voc @ 25C
- 48.06 V
- Efficiency
- 19.79%
How Does United Renewable Energy Co Ltd D6M380H4A Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for United Renewable Energy Co Ltd D6M380H4A (Mono-c-Si) residential solar systems.
United Renewable Energy Co Ltd D6M380H4A delivers 197.9 W/m2 (0.12 percentage points below 19.91% CEC median) and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (455 sq ft). At -4 F (-20 C), string voltage climbs to 54.92 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Auxin Solar AXN6M612T380 (380.0 W).
Where Does United Renewable Energy Co Ltd D6M380H4A Fall Across Listed CEC Models?
Comparison of United Renewable Energy Co Ltd D6M380H4A (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define United Renewable Energy Co Ltd D6M380H4A?
Relative ranking of United Renewable Energy Co Ltd D6M380H4A across nameplate watts, 91.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6M380H4A?
Summary of United Renewable Energy Co Ltd D6M380H4A output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.79% Aperture Efficiency
Power density 197.9 W/m2 (0.12 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.39 V at -10 C (587.3 V string) and 54.92 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 42.2 m2 (455 sq ft) producing 7,678 W PTC; NEC 690.8 OCPD floor is 15.77 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.06 * (1 + (-0.317/100) * (-10 - 25)) = 53.39 V | OCPD = 1.56 * 10.11 = 15.77 A
Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6M380H4A: Voc=48.06 V, beta_Voc=-0.317%/C, Isc=10.11 A, STC=380.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (587.3 V); 22 panels for 8 kW (455 sq ft).
What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6M380H4A?
Complete CEC test sheet for United Renewable Energy Co Ltd D6M380H4A including Isc (10.11 A), Voc (48.06 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 349.0 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.11 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.55 V / 9.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.317 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.79% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many United Renewable Energy Co Ltd D6M380H4A Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using United Renewable Energy Co Ltd D6M380H4A.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 331 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 455 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 558 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This United Renewable Energy Co Ltd Series?
Related United Renewable Energy Co Ltd power steps and black/silver trims consolidated into this United Renewable Energy Co Ltd D6M380H4A series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| United Renewable Energy Co Ltd D6M375H4A | 375.0 W | 344.3 W | 47.93 V | 39.45 V | 19.53% |
| United Renewable Energy Co Ltd D6M380H4A | 380.0 W | 349.0 W | 48.06 V | 39.55 V | 19.79% |
How Many United Renewable Energy Co Ltd D6M380H4A Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for United Renewable Energy Co Ltd D6M380H4A (48.06 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.92 V | 10 panels | 549.2 V | 18 panels |
| -10 C (14 F) | 53.39 V | 11 panels | 587.3 V | 18 panels |
| 0 C (32 F) | 51.87 V | 11 panels | 570.6 V | 19 panels |
| 25 C (77 F STC) | 48.06 V | 12 panels | 576.7 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6M380H4A?
Four comparable CEC modules such as Auxin Solar AXN6M612T380 (380.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| CertainTeed CT380M10-02 CertainTeed |
380.0 W | Tie (0 W) | 47.94 V | 20.19% | 92.0% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6M380H4A?
Evaluate United Renewable Energy Co Ltd D6M380H4A (380.0 W STC, 48.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6M380H4A reaches 54.92 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 455 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (455 sq ft).
- 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6M380H4A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
United Renewable Energy Co Ltd D6M380H4A 8 kW Residential Fit
Needs 22 modules (455 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN6M612T380.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for United Renewable Energy Co Ltd D6M380H4A by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many United Renewable Energy Co Ltd D6M380H4A panels fit on a 600 V winter solar string?
At -10 C (14 F), United Renewable Energy Co Ltd D6M380H4A cold Voc rises from 48.06 V to 53.39 V (beta_Voc -0.317%/C), capping a 600 V string at 11 panels (587.3 V).
How much roof area does an 8 kW array of United Renewable Energy Co Ltd D6M380H4A need?
An 8 kW DC system uses 22 United Renewable Energy Co Ltd D6M380H4A modules (8,360 W STC / 7,678 W PTC), covering roughly 455 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does United Renewable Energy Co Ltd D6M380H4A compare against Auxin Solar AXN6M612T380?
United Renewable Energy Co Ltd D6M380H4A outputs 380.0 W STC (48.06 V Voc, rank #11,043 of 21,677), while Auxin Solar AXN6M612T380 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)