Manufacturer: United Renewable Energy Co Ltd Registry: CEC Verified Engineering Specification

United Renewable Energy Co Ltd D6M300B3AME is a 300.0 W STC (268.0 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.44% efficiency, 39.39 V Voc at 25 C, and 44.22 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
268.0 W
Voc @ 25C
39.39 V
Efficiency
18.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does United Renewable Energy Co Ltd D6M300B3AME Compare Against Peer CEC Listings?

How United Renewable Energy Co Ltd United Renewable Energy Co Ltd D6M300B3AME handles rooftop heat (268.0 W PTC), 8 kW sizing, and cold winter string voltage.

United Renewable Energy Co Ltd builds the United Renewable Energy Co Ltd D6M300B3AME (Mono-c-Si) as a compact residential or specialty off-grid module delivering 184.4 W/m2 (1.47 percentage points below 19.91% CEC median). Compared against FreeVolt PV-GRAF-60M6-300/M (300.0 W), this model holds typical 89.3% PTC-to-STC thermal output (268.0 W real-world rating). Lower 39.39 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 15.26 A overcurrent floor served by a 20 A breaker.

Where Does United Renewable Energy Co Ltd D6M300B3AME Fall Across Listed CEC Models?

Where United Renewable Energy Co Ltd D6M300B3AME (300.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where United Renewable Energy Co Ltd D6M300B3AME (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUnited Renewable E: 300.0 W

What Dataset Percentiles Define United Renewable Energy Co Ltd D6M300B3AME?

Percentile placement of United Renewable Energy Co Ltd D6M300B3AME across power density (184.4 W/m2), thermal retention, and nameplate STC wattage.

United Renewable Energy Co Ltd D6M300B3AME Engineering BenchmarksPercentile comparison of United Renewable Energy Co Ltd D6M300B3AME wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention89.3%Module Efficiency18.44%

What Do the Dataset Ranks Show for United Renewable Energy Co Ltd D6M300B3AME?

Four critical engineering numbers homeowners and solar installers check first when reviewing United Renewable Energy Co Ltd D6M300B3AME specifications.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,436

18.44% Aperture Efficiency

Power density 184.4 W/m2 (1.47 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.22 V at -10 C (574.9 V string) and 45.59 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 43.9 m2 (473 sq ft) producing 7,236 W PTC; NEC 690.8 OCPD floor is 15.26 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.39 * (1 + (-0.35/100) * (-10 - 25)) = 44.22 V | OCPD = 1.56 * 9.78 = 15.26 A

Inputs from CEC Modules.csv for United Renewable Energy Co Ltd D6M300B3AME: Voc=39.39 V, beta_Voc=-0.35%/C, Isc=9.78 A, STC=300.0 W, Area=1.627 m2.

Result: 13 panels max on 600 V (574.9 V); 27 panels for 8 kW (473 sq ft).

What Are the Published CEC Specifications for United Renewable Energy Co Ltd D6M300B3AME?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for United Renewable Energy Co Ltd D6M300B3AME.

Official California Energy Commission (NREL SAM) test parameters for United Renewable Energy Co Ltd D6M300B3AME.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 268.0 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.39 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.78 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.09 V / 9.35 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.44% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many United Renewable Energy Co Ltd D6M300B3AME Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using United Renewable Energy Co Ltd D6M300B3AME (300.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 350 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 473 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 595 sq ft $2,553 $4,317

How Many United Renewable Energy Co Ltd D6M300B3AME Modules Fit in a Cold-Weather String?

Maximum series module counts for United Renewable Energy Co Ltd D6M300B3AME from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.39V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.59 V 13 panels 592.7 V 21 panels
-10 C (14 F) 44.22 V 13 panels 574.9 V 22 panels
0 C (32 F) 42.84 V 14 panels 599.8 V 23 panels
25 C (77 F STC) 39.39 V 15 panels 590.9 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to United Renewable Energy Co Ltd D6M300B3AME?

Alternative CEC solar modules from competing brands near United Renewable Energy Co Ltd D6M300B3AME (300.0 W), including FreeVolt PV-GRAF-60M6-300/M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
FreeVolt PV-GRAF-60M6-300/M
FreeVolt
300.0 W Tie (0 W) 39.6 V 18.29% 91.1%
CertainTeed CT300M10-01
CertainTeed
300.0 W Tie (0 W) 39.1 V 18.33% 91.0%
CertainTeed CT300M11-01
CertainTeed
300.0 W Tie (0 W) 39.1 V 18.33% 90.1%
Enphase Energy Inc XACM-IQ7-LR6-60PB-300M
Enphase Energy Inc
300.0 W Tie (0 W) 40.1 V 18.99% 91.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for United Renewable Energy Co Ltd D6M300B3AME?

Evaluate United Renewable Energy Co Ltd D6M300B3AME (300.0 W STC, 39.39 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), United Renewable Energy Co Ltd D6M300B3AME reaches 45.59 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 473 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (473 sq ft).
  • 2026 tax credit baseline: cash residential installs of United Renewable Energy Co Ltd D6M300B3AME carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

United Renewable Energy Co Ltd D6M300B3AME 8 kW Residential Fit

Needs 27 modules (473 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare FreeVolt PV-GRAF-60M6-300/M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for United Renewable Energy Co Ltd D6M300B3AME by United Renewable Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for United Renewable Energy Co Ltd D6M300B3AME?

Multiplying United Renewable Energy Co Ltd D6M300B3AME's 9.78 A short-circuit current by 1.56 equals 15.26 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can United Renewable Energy Co Ltd D6M300B3AME pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.22 V cold Voc at 14 F and handles 9.78 A Isc; string inverters cap United Renewable Energy Co Ltd D6M300B3AME at 13 panels on 600 V.

Is United Renewable Energy Co Ltd D6M300B3AME eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of United Renewable Energy Co Ltd D6M300B3AME rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.