TSEC TS72-AMH-435 H2 — CEC Solar Module Specifications

Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS72-AMH-435 H2 is a 435.0 W STC (402.5 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 49.1 V Voc at 25 C, and 54.26 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
402.5 W
Voc @ 25C
49.1 V
Efficiency
20.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS72-AMH-435 H2 Compare Against Peer CEC Listings?

Solar engineering breakdown for TSEC TS72-AMH-435 H2: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Across 5,889 Mono-c-Si listings from TSEC and peers, TSEC TS72-AMH-435 H2 stands 25.0 W above the 410.0 W Mono-c-Si median and strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 49.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does TSEC TS72-AMH-435 H2 Fall Across Listed CEC Models?

Distribution marker showing TSEC TS72-AMH-435 H2 (435.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS72-AMH-435 H2 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS72-AMH-435 : 435.0 W

What Dataset Percentiles Define TSEC TS72-AMH-435 H2?

Dataset percentiles tracking TSEC TS72-AMH-435 H2 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

TSEC TS72-AMH-435 H2 Engineering BenchmarksPercentile comparison of TSEC TS72-AMH-435 H2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention92.5%Module Efficiency20.14%

What Do the Dataset Ranks Show for TSEC TS72-AMH-435 H2?

Benchmark highlights for TSEC TS72-AMH-435 H2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.26 V at -10 C (596.9 V string) and 55.73 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,648 W PTC; NEC 690.8 OCPD floor is 17.72 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.1 * (1 + (-0.3/100) * (-10 - 25)) = 54.26 V | OCPD = 1.56 * 11.36 = 17.72 A

Inputs from CEC Modules.csv for TSEC TS72-AMH-435 H2: Voc=49.1 V, beta_Voc=-0.3%/C, Isc=11.36 A, STC=435.0 W, Area=2.16 m2.

Result: 11 panels max on 600 V (596.9 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for TSEC TS72-AMH-435 H2?

Official CEC datasheet figures for TSEC TS72-AMH-435 H2 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS72-AMH-435 H2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 402.5 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.8 V / 10.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.14% (2.16 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS72-AMH-435 H2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many TSEC TS72-AMH-435 H2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 326 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 442 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 535 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Consolidated TSEC wattage variants sharing the TSEC TS72-AMH-435 H2 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the TSEC TS72-AMH-435 H2 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS72-AMH-425 H2 425.0 W 393.0 W 48.7 V 40.4 V 19.68%
TSEC TS72-AMH-430 H2 430.0 W 397.8 W 48.9 V 40.6 V 19.91%
TSEC TS72-AMH-435 H2 435.0 W 402.5 W 49.1 V 40.8 V 20.14%
TSEC TS72-AMH-440 H2 440.0 W 407.3 W 49.2 V 41.0 V 20.37%
TSEC TS72-AMH-445 H2 445.0 W 412.1 W 49.4 V 41.2 V 20.6%

How Many TSEC TS72-AMH-435 H2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on TSEC TS72-AMH-435 H2 (54.26 V at 14 F).

Computed from Voc=49.1V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.73 V 10 panels 557.3 V 17 panels
-10 C (14 F) 54.26 V 11 panels 596.9 V 18 panels
0 C (32 F) 52.78 V 11 panels 580.6 V 18 panels
25 C (77 F STC) 49.1 V 12 panels 589.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS72-AMH-435 H2?

Competing CEC solar panels closest to TSEC TS72-AMH-435 H2 in nameplate wattage and Voc, starting with AXITEC AC-435MB/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435MB/144V
AXITEC
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS72-AMH-435 H2?

Evaluate TSEC TS72-AMH-435 H2 (435.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS72-AMH-435 H2 reaches 55.73 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TSEC TS72-AMH-435 H2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS72-AMH-435 H2 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-435MB/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 402.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS72-AMH-435 H2 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for TSEC TS72-AMH-435 H2?

Multiplying TSEC TS72-AMH-435 H2's 11.36 A short-circuit current by 1.56 equals 17.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can TSEC TS72-AMH-435 H2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.26 V cold Voc at 14 F and handles 11.36 A Isc; string inverters cap TSEC TS72-AMH-435 H2 at 11 panels on 600 V.

Is TSEC TS72-AMH-435 H2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TSEC TS72-AMH-435 H2 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.