TSEC TS72-AMH-435 H2 is a 435.0 W STC (402.5 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 49.1 V Voc at 25 C, and 54.26 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 402.5 W
- Voc @ 25C
- 49.1 V
- Efficiency
- 20.14%
How Does TSEC TS72-AMH-435 H2 Compare Against Peer CEC Listings?
Solar engineering breakdown for TSEC TS72-AMH-435 H2: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Across 5,889 Mono-c-Si listings from TSEC and peers, TSEC TS72-AMH-435 H2 stands 25.0 W above the 410.0 W Mono-c-Si median and strong 92.5% PTC-to-STC heat retention (#12,531 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 49.1 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does TSEC TS72-AMH-435 H2 Fall Across Listed CEC Models?
Distribution marker showing TSEC TS72-AMH-435 H2 (435.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define TSEC TS72-AMH-435 H2?
Dataset percentiles tracking TSEC TS72-AMH-435 H2 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for TSEC TS72-AMH-435 H2?
Benchmark highlights for TSEC TS72-AMH-435 H2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.14% Aperture Efficiency
Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.26 V at -10 C (596.9 V string) and 55.73 V at -20 C (10 max).
19 Panels = 8,265 W STC
Occupies 41.0 m2 (442 sq ft) producing 7,648 W PTC; NEC 690.8 OCPD floor is 17.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.1 * (1 + (-0.3/100) * (-10 - 25)) = 54.26 V | OCPD = 1.56 * 11.36 = 17.72 A
Inputs from CEC Modules.csv for TSEC TS72-AMH-435 H2: Voc=49.1 V, beta_Voc=-0.3%/C, Isc=11.36 A, STC=435.0 W, Area=2.16 m2.
Result: 11 panels max on 600 V (596.9 V); 19 panels for 8 kW (442 sq ft).
What Are the Published CEC Specifications for TSEC TS72-AMH-435 H2?
Official CEC datasheet figures for TSEC TS72-AMH-435 H2 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 402.5 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.8 V / 10.66 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.3 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.14% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many TSEC TS72-AMH-435 H2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many TSEC TS72-AMH-435 H2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 326 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 442 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 535 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This TSEC Series?
Consolidated TSEC wattage variants sharing the TSEC TS72-AMH-435 H2 mechanical and cell layout. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| TSEC TS72-AMH-425 H2 | 425.0 W | 393.0 W | 48.7 V | 40.4 V | 19.68% |
| TSEC TS72-AMH-430 H2 | 430.0 W | 397.8 W | 48.9 V | 40.6 V | 19.91% |
| TSEC TS72-AMH-435 H2 | 435.0 W | 402.5 W | 49.1 V | 40.8 V | 20.14% |
| TSEC TS72-AMH-440 H2 | 440.0 W | 407.3 W | 49.2 V | 41.0 V | 20.37% |
| TSEC TS72-AMH-445 H2 | 445.0 W | 412.1 W | 49.4 V | 41.2 V | 20.6% |
How Many TSEC TS72-AMH-435 H2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on TSEC TS72-AMH-435 H2 (54.26 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.73 V | 10 panels | 557.3 V | 17 panels |
| -10 C (14 F) | 54.26 V | 11 panels | 596.9 V | 18 panels |
| 0 C (32 F) | 52.78 V | 11 panels | 580.6 V | 18 panels |
| 25 C (77 F STC) | 49.1 V | 12 panels | 589.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to TSEC TS72-AMH-435 H2?
Competing CEC solar panels closest to TSEC TS72-AMH-435 H2 in nameplate wattage and Voc, starting with AXITEC AC-435MB/144V.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-435MB/144V AXITEC |
435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W Dehui Solar Power (Vietnam) CoLtd |
435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |
| AXITEC AC-435MH/144V AXITEC |
435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
| Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W Dehui Solar Power (Vietnam) CoLtd |
435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
What Are the Design Limits and Best-Fit Uses for TSEC TS72-AMH-435 H2?
Evaluate TSEC TS72-AMH-435 H2 (435.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), TSEC TS72-AMH-435 H2 reaches 55.73 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of TSEC TS72-AMH-435 H2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
TSEC TS72-AMH-435 H2 8 kW Residential Fit
Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-435MB/144V.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 402.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for TSEC TS72-AMH-435 H2 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for TSEC TS72-AMH-435 H2?
Multiplying TSEC TS72-AMH-435 H2's 11.36 A short-circuit current by 1.56 equals 17.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can TSEC TS72-AMH-435 H2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.26 V cold Voc at 14 F and handles 11.36 A Isc; string inverters cap TSEC TS72-AMH-435 H2 at 11 panels on 600 V.
Is TSEC TS72-AMH-435 H2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of TSEC TS72-AMH-435 H2 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)