Skip to main content
WireAndSun
Calculators
CEC PV Module

TSEC TS60-BMH-440 H1 — CEC Solar Module Specifications

Manufacturer: TSEC Registry: CEC Verified Engineering Specification

TSEC TS60-BMH-440 H1 is a 440.0 W STC (407.6 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.47% efficiency, 40.9 V Voc at 25 C, and 45.05 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
407.6 W
Voc @ 25C
40.9 V
Efficiency
20.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does TSEC TS60-BMH-440 H1 Compare Against Peer CEC Listings?

Engineering position of TSEC TS60-BMH-440 H1 (440.0 W STC) vs. CertainTeed CTM10440HC11-09 across 5,889 CEC Mono-c-Si solar modules.

Ranking #6,418 across 21,677 CEC solar panels (top 31.6%; higher than 68.4% of peers), TSEC TS60-BMH-440 H1 operates as a modern high-density residential and light-commercial module sitting 30.0 W above the 410.0 W Mono-c-Si median. Mid-range 40.9 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677), 19 panels occupy 440 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does TSEC TS60-BMH-440 H1 Fall Across Listed CEC Models?

Plots TSEC TS60-BMH-440 H1 at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where TSEC TS60-BMH-440 H1 (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTSEC TS60-BMH-440 : 440.0 W

What Dataset Percentiles Define TSEC TS60-BMH-440 H1?

Benchmarks TSEC TS60-BMH-440 H1 on STC wattage, thermal PTC/STC retention, and 20.47 aperture conversion efficiency against CEC peers.

TSEC TS60-BMH-440 H1 Engineering BenchmarksPercentile comparison of TSEC TS60-BMH-440 H1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention92.6%Module Efficiency20.47%

What Do the Dataset Ranks Show for TSEC TS60-BMH-440 H1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for TSEC TS60-BMH-440 H1 by TSEC.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,713

20.47% Aperture Efficiency

Power density 204.7 W/m2 (0.56 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.05 V at -10 C (585.6 V string) and 46.24 V at -20 C (12 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,744 W PTC; NEC 690.8 OCPD floor is 20.98 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.9 * (1 + (-0.29/100) * (-10 - 25)) = 45.05 V | OCPD = 1.56 * 13.45 = 20.98 A

Inputs from CEC Modules.csv for TSEC TS60-BMH-440 H1: Voc=40.9 V, beta_Voc=-0.29%/C, Isc=13.45 A, STC=440.0 W, Area=2.15 m2.

Result: 13 panels max on 600 V (585.6 V); 19 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for TSEC TS60-BMH-440 H1?

Laboratory test ratings recorded for TSEC TS60-BMH-440 H1 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for TSEC TS60-BMH-440 H1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 407.6 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.86 V / 13.01 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.29 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.47% (2.15 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many TSEC TS60-BMH-440 H1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (440 sq ft at 8 kW), and estimated Year-1 electric bill offset for TSEC TS60-BMH-440 H1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 324 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 440 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 532 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This TSEC Series?

Sibling wattage bins and frame colors grouped with TSEC TS60-BMH-440 H1 under TSEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the TSEC TS60-BMH-440 H1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
TSEC TS60-BMH-435 H1 435.0 W 402.9 W 40.75 V 33.71 V 20.23%
TSEC TS60-BMH-440 H1 440.0 W 407.6 W 40.9 V 33.86 V 20.47%
TSEC TS60-BMH-445 H1 445.0 W 412.4 W 41.05 V 34.01 V 20.7%

How Many TSEC TS60-BMH-440 H1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for TSEC TS60-BMH-440 H1 (beta_Voc -0.29%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.9V and beta_Voc=-0.29%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.24 V 12 panels 554.9 V 21 panels
-10 C (14 F) 45.05 V 13 panels 585.6 V 22 panels
0 C (32 F) 43.87 V 13 panels 570.3 V 22 panels
25 C (77 F STC) 40.9 V 14 panels 572.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to TSEC TS60-BMH-440 H1?

Closest cross-brand CEC competitors to TSEC TS60-BMH-440 H1 matched near 440.0 W STC and 40.9 V Voc, led by CertainTeed CTM10440HC11-09.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CTM10440HC11-09
CertainTeed
440.0 W Tie (0 W) 40.9 V 20.56% 93.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
440.0 W Tie (0 W) 41.0 V 20.37% 93.7%
CertainTeed CTM10440HC11-06
CertainTeed
440.0 W Tie (0 W) 41.02 V 20.37% 93.7%
Elin Energy (Sirius PV) ELNSM60M-HC-440
Elin Energy (Sirius PV)
440.0 W Tie (0 W) 41.12 V 20.47% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for TSEC TS60-BMH-440 H1?

Evaluate TSEC TS60-BMH-440 H1 (440.0 W STC, 40.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), TSEC TS60-BMH-440 H1 reaches 46.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of TSEC TS60-BMH-440 H1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

TSEC TS60-BMH-440 H1 8 kW Residential Fit

Needs 19 modules (440 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CertainTeed CTM10440HC11-09.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 407.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for TSEC TS60-BMH-440 H1 by TSEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many TSEC TS60-BMH-440 H1 panels fit on a 600 V winter solar string?

At -10 C (14 F), TSEC TS60-BMH-440 H1 cold Voc rises from 40.9 V to 45.05 V (beta_Voc -0.29%/C), capping a 600 V string at 13 panels (585.6 V).

How much roof area does an 8 kW array of TSEC TS60-BMH-440 H1 need?

An 8 kW DC system uses 19 TSEC TS60-BMH-440 H1 modules (8,360 W STC / 7,744 W PTC), covering roughly 440 sq ft and saving ~$2,092/yr at 18.54 c/kWh.

How does TSEC TS60-BMH-440 H1 compare against CertainTeed CTM10440HC11-09?

TSEC TS60-BMH-440 H1 outputs 440.0 W STC (40.9 V Voc, rank #6,418 of 21,677), while CertainTeed CTM10440HC11-09 delivers 440.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.