Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-405DE09C07 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-405DE09C07 is a 405.0 W STC (378.0 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.2% efficiency, 41.4 V Voc at 25 C, and 45.11 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
378.0 W
Voc @ 25C
41.4 V
Efficiency
21.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-405DE09C07 Compare Against Peer CEC Listings?

Solar engineering breakdown for Trina Solar TSM-405DE09C07: PTC thermal retention, roof footprint, and cold Voc string bounds. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Across 5,889 Mono-c-Si listings from Trina Solar and peers, Trina Solar TSM-405DE09C07 stands 5.0 W below the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Mid-range 41.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-405DE09C07 Fall Across Listed CEC Models?

Distribution marker showing Trina Solar TSM-405DE09C07 (405.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-405DE09C07 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-40: 405.0 W

What Dataset Percentiles Define Trina Solar TSM-405DE09C07?

Dataset percentiles tracking Trina Solar TSM-405DE09C07 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Trina Solar TSM-405DE09C07 Engineering BenchmarksPercentile comparison of Trina Solar TSM-405DE09C07 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.3%Module Efficiency21.2%

What Do the Dataset Ranks Show for Trina Solar TSM-405DE09C07?

Benchmark highlights for Trina Solar TSM-405DE09C07 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,580

21.2% Aperture Efficiency

Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.11 V at -10 C (586.4 V string) and 46.17 V at -20 C (12 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.2 m2 (411 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 19.25 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.256/100) * (-10 - 25)) = 45.11 V | OCPD = 1.56 * 12.34 = 19.25 A

Inputs from CEC Modules.csv for Trina Solar TSM-405DE09C07: Voc=41.4 V, beta_Voc=-0.256%/C, Isc=12.34 A, STC=405.0 W, Area=1.91 m2.

Result: 13 panels max on 600 V (586.4 V); 20 panels for 8 kW (411 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-405DE09C07?

Official CEC datasheet figures for Trina Solar TSM-405DE09C07 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-405DE09C07.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 378.0 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.4 V / 11.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.256 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.2% (1.91 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-405DE09C07 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Trina Solar TSM-405DE09C07 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 308 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 411 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 514 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-405DE09C07 mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the Trina Solar TSM-405DE09C07 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-400DE09C07 400.0 W 373.2 W 41.2 V 34.2 V 20.94%
Trina Solar TSM-405DE09C07 405.0 W 378.0 W 41.4 V 34.4 V 21.2%

How Many Trina Solar TSM-405DE09C07 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-405DE09C07 (45.11 V at 14 F).

Computed from Voc=41.4V and beta_Voc=-0.256%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.17 V 12 panels 554.0 V 21 panels
-10 C (14 F) 45.11 V 13 panels 586.4 V 22 panels
0 C (32 F) 44.05 V 13 panels 572.6 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-405DE09C07?

Competing CEC solar panels closest to Trina Solar TSM-405DE09C07 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-405MS {Wht}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-405MS {Wht}
CSI Solar Co Ltd
405.0 W Tie (0 W) 44.7 V 20.56% 93.5%
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-405DE09C07?

Evaluate Trina Solar TSM-405DE09C07 (405.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-405DE09C07 reaches 46.17 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-405DE09C07 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-405DE09C07 8 kW Residential Fit

Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-405DE09C07 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-405DE09C07?

Multiplying Trina Solar TSM-405DE09C07's 12.34 A short-circuit current by 1.56 equals 19.25 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Trina Solar TSM-405DE09C07 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.11 V cold Voc at 14 F and handles 12.34 A Isc; string inverters cap Trina Solar TSM-405DE09C07 at 13 panels on 600 V.

Is Trina Solar TSM-405DE09C07 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-405DE09C07 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.