Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-405DE09C05 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-405DE09C05 is a 405.0 W STC (378.0 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.2% efficiency, 41.4 V Voc at 25 C, and 45.11 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
378.0 W
Voc @ 25C
41.4 V
Efficiency
21.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-405DE09C05 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-405DE09C05 handles rooftop heat (378.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-405DE09C05 exhibits 12.34 A short-circuit current, requiring a 19.25 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #8,961 of 21,677 (5.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.2 m2 for an 8 kW system (25 panels for 10 kW). Mid-range 41.4 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-405DE09C05 Fall Across Listed CEC Models?

Where Trina Solar TSM-405DE09C05 (405.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-405DE09C05 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-40: 405.0 W

What Dataset Percentiles Define Trina Solar TSM-405DE09C05?

Percentile placement of Trina Solar TSM-405DE09C05 across power density (212.0 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-405DE09C05 Engineering BenchmarksPercentile comparison of Trina Solar TSM-405DE09C05 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.3%Module Efficiency21.2%

What Do the Dataset Ranks Show for Trina Solar TSM-405DE09C05?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-405DE09C05 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,580

21.2% Aperture Efficiency

Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.11 V at -10 C (586.4 V string) and 46.17 V at -20 C (12 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.2 m2 (411 sq ft) producing 7,560 W PTC; NEC 690.8 OCPD floor is 19.25 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.256/100) * (-10 - 25)) = 45.11 V | OCPD = 1.56 * 12.34 = 19.25 A

Inputs from CEC Modules.csv for Trina Solar TSM-405DE09C05: Voc=41.4 V, beta_Voc=-0.256%/C, Isc=12.34 A, STC=405.0 W, Area=1.91 m2.

Result: 13 panels max on 600 V (586.4 V); 20 panels for 8 kW (411 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-405DE09C05?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-405DE09C05.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-405DE09C05.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 378.0 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.4 V / 11.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.256 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.2% (1.91 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-405DE09C05 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-405DE09C05 (405.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 308 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 411 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 514 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-405DE09C05 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the Trina Solar TSM-405DE09C05 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-400DE09C05 400.0 W 373.2 W 41.2 V 34.2 V 20.94%
Trina Solar TSM-405DE09C05 405.0 W 378.0 W 41.4 V 34.4 V 21.2%

How Many Trina Solar TSM-405DE09C05 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-405DE09C05 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.4V and beta_Voc=-0.256%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.17 V 12 panels 554.0 V 21 panels
-10 C (14 F) 45.11 V 13 panels 586.4 V 22 panels
0 C (32 F) 44.05 V 13 panels 572.6 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-405DE09C05?

Alternative CEC solar modules from competing brands near Trina Solar TSM-405DE09C05 (405.0 W), including CSI Solar Co Ltd CS3N-405MS {Wht}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-405MS {Wht}
CSI Solar Co Ltd
405.0 W Tie (0 W) 44.7 V 20.56% 93.5%
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-405DE09C05?

Evaluate Trina Solar TSM-405DE09C05 (405.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-405DE09C05 reaches 46.17 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-405DE09C05 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-405DE09C05 8 kW Residential Fit

Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-405DE09C05 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-405DE09C05 PTC wattage (378.0 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 378.0 W PTC (93.3% retention) across Trina Solar TSM-405DE09C05's 1.91 m2 aperture.

Who should skip Trina Solar TSM-405DE09C05 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Trina Solar TSM-405DE09C05 panels (411 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-405MS {Wht}.

What is the 1,000 V commercial string limit for Trina Solar TSM-405DE09C05?

On 1,000 V commercial inverters at -10 C (45.11 V cold Voc), Trina Solar TSM-405DE09C05 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-405DE09C05.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.