Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-405DE0905 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-405DE0905 is a 405.0 W STC (381.6 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.2% efficiency, 41.4 V Voc at 25 C, and 44.83 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
381.6 W
Voc @ 25C
41.4 V
Efficiency
21.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-405DE0905 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-405DE0905 (Mono-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-405DE0905 need 15 panels for 6 kW or 20 panels (411 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.237%/C) pushes open-circuit voltage to 44.83 V at 14 F and 45.82 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-405DE0905 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-405DE0905 (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-405DE0905 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-40: 405.0 W

What Dataset Percentiles Define Trina Solar TSM-405DE0905?

Relative ranking of Trina Solar TSM-405DE0905 across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Trina Solar TSM-405DE0905 Engineering BenchmarksPercentile comparison of Trina Solar TSM-405DE0905 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention94.2%Module Efficiency21.2%

What Do the Dataset Ranks Show for Trina Solar TSM-405DE0905?

Summary of Trina Solar TSM-405DE0905 output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,580

21.2% Aperture Efficiency

Power density 212.0 W/m2 (1.29 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.83 V at -10 C (582.8 V string) and 45.82 V at -20 C (13 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.2 m2 (411 sq ft) producing 7,632 W PTC; NEC 690.8 OCPD floor is 19.25 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.4 * (1 + (-0.237/100) * (-10 - 25)) = 44.83 V | OCPD = 1.56 * 12.34 = 19.25 A

Inputs from CEC Modules.csv for Trina Solar TSM-405DE0905: Voc=41.4 V, beta_Voc=-0.237%/C, Isc=12.34 A, STC=405.0 W, Area=1.91 m2.

Result: 13 panels max on 600 V (582.8 V); 20 panels for 8 kW (411 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-405DE0905?

Complete CEC test sheet for Trina Solar TSM-405DE0905 including Isc (12.34 A), Voc (41.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-405DE0905.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 381.6 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.4 V / 11.77 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.2% (1.91 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-405DE0905 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-405DE0905.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 308 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 411 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 514 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-405DE0905 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Trina Solar TSM-405DE0905 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-400DE0905 400.0 W 376.8 W 41.2 V 34.2 V 20.94%
Trina Solar TSM-405DE0905 405.0 W 381.6 W 41.4 V 34.4 V 21.2%

How Many Trina Solar TSM-405DE0905 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-405DE0905 (41.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.4V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.82 V 13 panels 595.7 V 21 panels
-10 C (14 F) 44.83 V 13 panels 582.8 V 22 panels
0 C (32 F) 43.85 V 13 panels 570.1 V 22 panels
25 C (77 F STC) 41.4 V 14 panels 579.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-405DE0905?

Four comparable CEC modules such as CSI Solar Co Ltd CS3N-405MS {Wht} (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-405MS {Wht}
CSI Solar Co Ltd
405.0 W Tie (0 W) 44.7 V 20.56% 93.5%
Alexus Solar ALEX-405-B-54-S
Alexus Solar
405.0 W Tie (0 W) 37.38 V 20.77% 92.5%
Convalt Manufacturing LLC CVLT405-108M-BB
Convalt Manufacturing LLC
405.0 W Tie (0 W) 37.36 V 20.88% 92.0%
AMPS Solar AMPS-405P-54BB
AMPS Solar
405.0 W Tie (0 W) 37.25 V 20.88% 94.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-405DE0905?

Evaluate Trina Solar TSM-405DE0905 (405.0 W STC, 41.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-405DE0905 reaches 45.82 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 411 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (411 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-405DE0905 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-405DE0905 8 kW Residential Fit

Needs 20 modules (411 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3N-405MS {Wht}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 381.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-405DE0905 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-405DE0905 PTC wattage (381.6 W) lower than STC (405.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 381.6 W PTC (94.2% retention) across Trina Solar TSM-405DE0905's 1.91 m2 aperture.

Who should skip Trina Solar TSM-405DE0905 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Trina Solar TSM-405DE0905 panels (411 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3N-405MS {Wht}.

What is the 1,000 V commercial string limit for Trina Solar TSM-405DE0905?

On 1,000 V commercial inverters at -10 C (44.83 V cold Voc), Trina Solar TSM-405DE0905 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-405DE0905.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.