Trina Solar TSM-380DEG14H(II) is a 380.0 W STC (355.0 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.19% efficiency, 48.0 V Voc at 25 C, and 52.52 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 355.0 W
- Voc @ 25C
- 48.0 V
- Efficiency
- 19.19%
How Does Trina Solar TSM-380DEG14H(II) Compare Against Peer CEC Listings?
How Trina Solar Trina Solar TSM-380DEG14H(II) handles rooftop heat (355.0 W PTC), 8 kW sizing, and cold winter string voltage.
Trina Solar builds the Trina Solar TSM-380DEG14H(II) (Mono-c-Si) as a compact residential or specialty off-grid module delivering 191.9 W/m2 (0.72 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6M612T380 (380.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Higher 48.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 15.58 A overcurrent floor served by a 20 A breaker.
Where Does Trina Solar TSM-380DEG14H(II) Fall Across Listed CEC Models?
Where Trina Solar TSM-380DEG14H(II) (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Trina Solar TSM-380DEG14H(II)?
Percentile placement of Trina Solar TSM-380DEG14H(II) across power density (191.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Trina Solar TSM-380DEG14H(II)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-380DEG14H(II) specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.19% Aperture Efficiency
Power density 191.9 W/m2 (0.72 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.52 V at -10 C (577.7 V string) and 53.81 V at -20 C (11 max).
22 Panels = 8,360 W STC
Occupies 43.6 m2 (469 sq ft) producing 7,810 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.0 * (1 + (-0.269/100) * (-10 - 25)) = 52.52 V | OCPD = 1.56 * 9.99 = 15.58 A
Inputs from CEC Modules.csv for Trina Solar TSM-380DEG14H(II): Voc=48.0 V, beta_Voc=-0.269%/C, Isc=9.99 A, STC=380.0 W, Area=1.98 m2.
Result: 11 panels max on 600 V (577.7 V); 22 panels for 8 kW (469 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-380DEG14H(II)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-380DEG14H(II).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 355.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.99 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.6 V / 9.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.19% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-380DEG14H(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-380DEG14H(II) (380.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 341 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 469 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 575 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-380DEG14H(II) architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-375DEG14H(II) | 375.0 W | 350.2 W | 47.8 V | 39.4 V | 18.94% |
| Trina Solar TSM-380DEG14H(II) | 380.0 W | 355.0 W | 48.0 V | 39.6 V | 19.19% |
| Trina Solar TSM-385DEG14H(II) | 385.0 W | 359.7 W | 48.5 V | 40.1 V | 19.44% |
How Many Trina Solar TSM-380DEG14H(II) Modules Fit in a Cold-Weather String?
Maximum series module counts for Trina Solar TSM-380DEG14H(II) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.81 V | 11 panels | 591.9 V | 18 panels |
| -10 C (14 F) | 52.52 V | 11 panels | 577.7 V | 19 panels |
| 0 C (32 F) | 51.23 V | 11 panels | 563.5 V | 19 panels |
| 25 C (77 F STC) | 48.0 V | 12 panels | 576.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-380DEG14H(II)?
Alternative CEC solar modules from competing brands near Trina Solar TSM-380DEG14H(II) (380.0 W), including Auxin Solar AXN6M612T380.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| CertainTeed CT380M10-02 CertainTeed |
380.0 W | Tie (0 W) | 47.94 V | 20.19% | 92.0% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-380DEG14H(II)?
Evaluate Trina Solar TSM-380DEG14H(II) (380.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-380DEG14H(II) reaches 53.81 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-380DEG14H(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-380DEG14H(II) 8 kW Residential Fit
Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T380.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 355.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-380DEG14H(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-380DEG14H(II)?
Multiplying Trina Solar TSM-380DEG14H(II)'s 9.99 A short-circuit current by 1.56 equals 15.58 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Trina Solar TSM-380DEG14H(II) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.52 V cold Voc at 14 F and handles 9.99 A Isc; string inverters cap Trina Solar TSM-380DEG14H(II) at 11 panels on 600 V.
Is Trina Solar TSM-380DEG14H(II) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-380DEG14H(II) rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)