Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-380DE14H(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-380DE14H(II) is a 380.0 W STC (354.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.39% efficiency, 48.0 V Voc at 25 C, and 52.6 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
354.6 W
Voc @ 25C
48.0 V
Efficiency
19.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-380DE14H(II) Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-380DE14H(II) (Mono-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-380DE14H(II) need 16 panels for 6 kW or 22 panels (464 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (464 sq ft). Under NEC 690.7(A), beta_Voc (-0.274%/C) pushes open-circuit voltage to 52.6 V at 14 F and 53.92 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-380DE14H(II) Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-380DE14H(II) (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-380DE14H(II) (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-38: 380.0 W

What Dataset Percentiles Define Trina Solar TSM-380DE14H(II)?

Relative ranking of Trina Solar TSM-380DE14H(II) across nameplate watts, 93.3% PTC thermal ratio, and module aperture efficiency.

Trina Solar TSM-380DE14H(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-380DE14H(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.3%Module Efficiency19.39%

What Do the Dataset Ranks Show for Trina Solar TSM-380DE14H(II)?

Summary of Trina Solar TSM-380DE14H(II) output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,481

19.39% Aperture Efficiency

Power density 193.9 W/m2 (0.52 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.6 V at -10 C (578.6 V string) and 53.92 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 43.1 m2 (464 sq ft) producing 7,801 W PTC; NEC 690.8 OCPD floor is 15.58 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.0 * (1 + (-0.274/100) * (-10 - 25)) = 52.6 V | OCPD = 1.56 * 9.99 = 15.58 A

Inputs from CEC Modules.csv for Trina Solar TSM-380DE14H(II): Voc=48.0 V, beta_Voc=-0.274%/C, Isc=9.99 A, STC=380.0 W, Area=1.96 m2.

Result: 11 panels max on 600 V (578.6 V); 22 panels for 8 kW (464 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-380DE14H(II)?

Complete CEC test sheet for Trina Solar TSM-380DE14H(II) including Isc (9.99 A), Voc (48.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-380DE14H(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 354.6 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.99 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.6 V / 9.6 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.274 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.39% (1.96 m2) Array roof footprint density
Cell Count & Technology 48 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-380DE14H(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-380DE14H(II).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 338 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 464 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 570 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-380DE14H(II) series guide.

Sibling CEC listings grouped into the Trina Solar TSM-380DE14H(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-375DE14H(II) 375.0 W 349.8 W 47.8 V 39.4 V 19.13%
Trina Solar TSM-380DE14H(II) 380.0 W 354.6 W 48.0 V 39.6 V 19.39%
Trina Solar TSM-385DE14H(II) 385.0 W 359.4 W 48.5 V 40.1 V 19.64%

How Many Trina Solar TSM-380DE14H(II) Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-380DE14H(II) (48.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.0V and beta_Voc=-0.274%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.92 V 11 panels 593.1 V 18 panels
-10 C (14 F) 52.6 V 11 panels 578.6 V 19 panels
0 C (32 F) 51.29 V 11 panels 564.2 V 19 panels
25 C (77 F STC) 48.0 V 12 panels 576.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-380DE14H(II)?

Four comparable CEC modules such as Auxin Solar AXN6M612T380 (380.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612T380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.58% 91.9%
CertainTeed CT380M10-02
CertainTeed
380.0 W Tie (0 W) 47.94 V 20.19% 92.0%
Bluesun Solar Energy Tech CoLtd BSM380M-72
Bluesun Solar Energy Tech CoLtd
380.0 W Tie (0 W) 48.67 V 19.59% 92.0%
Caterpillar Inc PVC380MP03H
Caterpillar Inc
380.0 W Tie (0 W) 49.0 V 19.63% 94.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-380DE14H(II)?

Evaluate Trina Solar TSM-380DE14H(II) (380.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-380DE14H(II) reaches 53.92 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 464 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (464 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-380DE14H(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-380DE14H(II) 8 kW Residential Fit

Needs 22 modules (464 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T380.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 354.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-380DE14H(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-380DE14H(II) PTC wattage (354.6 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 354.6 W PTC (93.3% retention) across Trina Solar TSM-380DE14H(II)'s 1.96 m2 aperture.

Who should skip Trina Solar TSM-380DE14H(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Trina Solar TSM-380DE14H(II) panels (464 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612T380.

What is the 1,000 V commercial string limit for Trina Solar TSM-380DE14H(II)?

On 1,000 V commercial inverters at -10 C (52.6 V cold Voc), Trina Solar TSM-380DE14H(II) fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-380DE14H(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.