Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-380DE06XC07(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-380DE06XC07(II) is a 380.0 W STC (353.9 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.88% efficiency, 45.5 V Voc at 25 C, and 49.69 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
353.9 W
Voc @ 25C
45.5 V
Efficiency
20.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-380DE06XC07(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-380DE06XC07(II) handles rooftop heat (353.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-380DE06XC07(II) exhibits 10.51 A short-circuit current, requiring a 16.4 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,043 of 21,677 (30.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 40.0 m2 for an 8 kW system (27 panels for 10 kW). Mid-range 45.5 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-380DE06XC07(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-380DE06XC07(II) (380.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-380DE06XC07(II) (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-38: 380.0 W

What Dataset Percentiles Define Trina Solar TSM-380DE06XC07(II)?

Percentile placement of Trina Solar TSM-380DE06XC07(II) across power density (208.8 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-380DE06XC07(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-380DE06XC07(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.1%Module Efficiency20.88%

What Do the Dataset Ranks Show for Trina Solar TSM-380DE06XC07(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-380DE06XC07(II) specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,925

20.88% Aperture Efficiency

Power density 208.8 W/m2 (0.97 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.69 V at -10 C (596.3 V string) and 50.88 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,786 W PTC; NEC 690.8 OCPD floor is 16.4 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.5 * (1 + (-0.263/100) * (-10 - 25)) = 49.69 V | OCPD = 1.56 * 10.51 = 16.4 A

Inputs from CEC Modules.csv for Trina Solar TSM-380DE06XC07(II): Voc=45.5 V, beta_Voc=-0.263%/C, Isc=10.51 A, STC=380.0 W, Area=1.82 m2.

Result: 12 panels max on 600 V (596.3 V); 22 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-380DE06XC07(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-380DE06XC07(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-380DE06XC07(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 353.9 W (93.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.51 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 10.07 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.88% (1.82 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-380DE06XC07(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-380DE06XC07(II) (380.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 313 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 431 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 529 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-380DE06XC07(II) architecture. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Trina Solar TSM-380DE06XC07(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-375DE06XC07(II) 375.0 W 349.1 W 45.3 V 37.6 V 20.6%
Trina Solar TSM-380DE06XC07(II) 380.0 W 353.9 W 45.5 V 37.8 V 20.88%

How Many Trina Solar TSM-380DE06XC07(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-380DE06XC07(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.5V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.88 V 11 panels 559.7 V 19 panels
-10 C (14 F) 49.69 V 12 panels 596.3 V 20 panels
0 C (32 F) 48.49 V 12 panels 581.9 V 20 panels
25 C (77 F STC) 45.5 V 13 panels 591.5 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-380DE06XC07(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-380DE06XC07(II) (380.0 W), including CSI Solar Co Ltd CS6XH-375M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6XH-375M
CSI Solar Co Ltd
375.0 W -5.0 W 45.6 V 20.27% 93.0%
EMMVEE Photovoltaic Power Private Limited E385M72-B
EMMVEE Photovoltaic Power Private Limited
385.0 W +5.0 W 45.9 V 19.32% 91.5%
Auxin Solar AXN6M612T380
Auxin Solar
380.0 W Tie (0 W) 47.94 V 19.58% 91.9%
CertainTeed CT380M10-02
CertainTeed
380.0 W Tie (0 W) 47.94 V 20.19% 92.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-380DE06XC07(II)?

Evaluate Trina Solar TSM-380DE06XC07(II) (380.0 W STC, 45.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-380DE06XC07(II) reaches 50.88 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 431 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (431 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-380DE06XC07(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-380DE06XC07(II) 8 kW Residential Fit

Needs 22 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-375M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 353.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-380DE06XC07(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-380DE06XC07(II) PTC wattage (353.9 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 353.9 W PTC (93.1% retention) across Trina Solar TSM-380DE06XC07(II)'s 1.82 m2 aperture.

Who should skip Trina Solar TSM-380DE06XC07(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Trina Solar TSM-380DE06XC07(II) panels (431 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6XH-375M.

What is the 1,000 V commercial string limit for Trina Solar TSM-380DE06XC07(II)?

On 1,000 V commercial inverters at -10 C (49.69 V cold Voc), Trina Solar TSM-380DE06XC07(II) fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-380DE06XC07(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.